27 research outputs found

    Haematological and biochemical parameters in Churra-da-Terra-Quente ewes from the northeast of Portugal

    Get PDF
    Hematological and biochemical parameters, including plasma electrolytes and thyroid hormones, were determined in 73 clinically healthy Churra-da-Terra-Quente ewes, a typical breed from the northeast of Portugal. The hemogram values were: erythrocytes 9.8±1.51012/L; haemoglobin 118.1±19.1g/L; haematocrit 40.8±5.9%; leukocytes 5.7±1.8109/L; and platelets 544.3±177.2109/L. The thrombin time was 17.3±1.7 seconds. The values of biochemical parameters were: total protein 76.4±6.1g/L; glucose 2.87±0.60mmol/L; total cholesterol 1.65±0.33mmol/L; aspartate aminotransferase 155.9±49.2U/L; alanine aminotransferase 23.2±9.6U/L; γ-glutamyl transferase 48.0±18.7U/L; total alkaline phosphatase 121.6±76.1U/L; glutamate dehydrogenase 6.4±3.7U/L; urea 7.32±2.22mmol/L; creatinine 123.0±54.1μmol/L; total calcium 2.53±0.25mmol/L; phosphorus 2.10±0.46mmol/L; magnesium 1.01±0.09mmol/L; sodium 152.04±3.65mmol/L; potassium 4.7±0.4mmol/L; ionized calcium 1.32±0.07mmol/L; total thyroxine 111.75±42.29nmol/L; total triiodothyronine 1.01±0.28nmol/L; free T4 11.93±1.78pmol/L; free T3 4.22±1.33pmol/L; and thyroid-stimulating hormone 0.18±0.19μIU/mL. Although differences among the Churra-da-Terra-Quente breed and other breeds may occur, the hematological and biochemical parameters, plasma electrolytes, and thyroid hormones, for this indigenous breed, were generally situated within the reference intervals previously reported for sheep

    Silent cerebral infarction and cognitive function following TAVI: an observational two-centre UK comparison of the first-generation CoreValve and second-generation Lotus valve.

    Get PDF
    OBJECTIVE: To compare the incidence of silent cerebral infarction and impact on cognitive function following transcatheter aortic valve implantation (TAVI) with the first-generation CoreValve (Medtronic, Minneapolis, Minnesota, USA) and second-generation Lotus valve (Boston Scientific, Natick Massachusetts, USA). DESIGN: A prospective observational study comprising a 1.5 T cerebral MRI scan, performed preoperatively and immediately following TAVI, and neurocognitive assessments performed at baseline, 30 days and 1 year follow-up. SETTING: University hospitals of Leeds and Leicester, UK. PATIENTS: 66 (80.6±8.0 years, 47% male) patients with high-risk severe symptomatic aortic stenosis recruited between April 2012 and May 2015. MAIN OUTCOME MEASURES: Incidence of new cerebral microinfarction and objective decline in neurocognitive performance. RESULTS: All underwent cerebral MRI at baseline and immediately following TAVI, and 49 (25 Lotus, 24 CoreValve) completed neurocognitive assessments at baseline, 30 days and 1 year. There was a significantly greater incidence of new cerebral microinfarction observed following the Lotus TAVI (23 (79%) vs 22 (59%), p=0.025) with a greater number of new infarcts per patient (median 3.5 (IQR 7.0) vs 2.0 (IQR 3.0), p=0.002). The mean volume of infarcted cerebral tissue per patient was equivalent following the two prostheses (p=0.166). More patients suffered new anterior (14 (48%) vs 2 (5%), p=0.001) and vertebrobasilar (15 (52%) vs 7 (19%), p=0.005) lesions following Lotus. Lotus was associated with a decline in verbal memory and psychomotor speed at 30 days. However, performance longitudinally at 1 year was preserved in all neurocognitive domains. CONCLUSIONS: There was a higher incidence of silent cerebral microinfarction and a greater number of lesions per patient following Lotus compared with CoreValve. However, there was no objective decline in neurocognitive function discernible at 1 year following TAVI with either prosthesis

    Visualization of Protein Interactions in Living Cells

    No full text
    corecore