20 research outputs found

    Competitor presence reduces internal attentional focus and improves 16.1km cycling time trial performance.

    Get PDF
    Objectives: Whilst the presence of a competitor has been found to improve performance, the mechanisms influencing the change in selected work rates during direct competition have been suggested but not specifically assessed. The aim was to investigate the physiological and psychological influences of a visual avatar competitor during a 16.1-km cycling time trial performance, using trained, competitive cyclists. Design: Randomised cross-over design. Methods: Fifteen male cyclists completed four 16.1 km cycling time trials on a cycle ergometer, performing two with a visual display of themselves as a simulated avatar (FAM and SELF), one with no visual display(DO), and one with themselves and an opponent as simulated avatars (COMP). Participants were informed the competitive avatar was a similar ability cyclist but it was actually a representation of their fastest previous performance. Results: Increased performance times were evident during COMP (27.8 ± 2.0 min) compared to SELF(28.7 ± 1.9 min) and DO (28.4 ± 2.3 min). Greater power output, speed and heart rate were apparent during COMP trial than SELF (p < 0.05) and DO (p ≤ 0.06). There were no differences between SELF and DO.Ratings of perceived exertion were unchanged across all conditions. Internal attentional focus was significantly reduced during COMP trial (p < 0.05), suggesting reduced focused on internal sensations during an increase in performance. Conclusions: Competitive cyclists performed significantly faster during a 16.1-km competitive trial than when performing maximally, without a competitor. The improvement in performance was elicited due to a greater external distraction, deterring perceived exertion

    Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma ? method-comparison evaluations

    Full text link
    Increased plasma lactate levels can indicate the presence of metabolic disorders in HIV infected individuals. Objective: To determine whether a portable analyzer is valid for measuring cerebrospinal fluid (CSF) and plasma lactate levels in HIV infected individuals. Method: CSF and plasma were collected from 178 subjects. Samples tested by the Accutrend® portable analyzer were compared to those tested by a reference device (SYNCHRON LX® 20). Results: The portable analyzer had in plasma sensitivity of 0.95 and specificity 0.87. For CSF the specificity was 0.95; the sensitivity 0.33; the negative predictive value was 95% and the positive predictive value 33%. Conclusions: These findings support the validity of the portable analyzer in measuring lactate concentrations in CSF that fall within the normal range. The relatively poor positive predictive value indicates that a result above the reference range may represent a “false positive test”, and should be confirmed by the reference device before concluding abnormality
    corecore