32 research outputs found

    Analysis of nickel concentration profiles around the roots of the hyperaccumulator plant Berkheya coddii using MRI and numerical simulations

    Get PDF
    Investigations of soil-root interactions are hampered by the difficult experimental accessibility of the rhizosphere. Here we show the potential of Magnetic Resonance Imaging (MRI) as a non-destructive measurement technique in combination with numerical modelling to study the dynamics of the spatial distribution of dissolved nickel (Ni2+) around the roots of the nickel hyperaccumulator plant Berkheya coddii. Special rhizoboxes were used in which a root monolayer had been grown, separated from an adjacent inert glass bead packing by a nylon membrane. After applying a Ni2+ solution of 10mgl−1, the rhizobox was imaged repeatedly using MRI. The obtained temporal sequence of 2-dimensional Ni2+ maps in the vicinity of the roots showed that Ni2+ concentrations increased towards the root plane, revealing an accumulation pattern. Numerical modelling supported the Ni2+ distributions to result from advective water flow towards the root plane, driven by transpiration, and diffusion of Ni2+ tending to eliminate the concentration gradient. With the model, we could study how the accumulation pattern of Ni2+ in the root zone transforms into a depletion pattern depending on transpiration rate, solute uptake rate, and Ni2+ concentration in solutio

    Space power distribution system technology. Volume 1: Reference EPS design

    Get PDF
    The multihundred kilowatt electrical power aspects of a mannable space platform in low Earth orbit is analyzed from a cost and technology viewpoint. At the projected orbital altitudes, Shuttle launch and servicing are technically and economically viable. Power generation is specified as photovoltaic consistent with projected planning. The cost models and trades are based upon a zero interest rate (the government taxes concurrently as required), constant dollars (1980), and costs derived in the first half of 1980. Space platform utilization of up to 30 years is evaluated to fully understand the impact of resupply and replacement as satellite missions are extended. Such lifetimes are potentially realizable with Shuttle servicing capability and are economically desirable

    Adaptive receiver arrays for magnetic resonance imaging

    Full text link
    In den letzten zwanzig Jahren hat sich die Magnetresonanztomographie (MRT) zu einer der wichtigsten und vielseitigsten klinischen Untersuchungsmethoden entwickelt, da sich mit ihrer Hilfe nichtinvasiv unterschiedliche Arten von Informationen aus dem Inneren des menschlichen Körpers mit hoher räumlicher Auflösung und ausgezeichnetem Weichteilkontrast gewinnen lassen. Das zugrunde liegende Prinzip ist die elektromagnetische Anregung von Atomkernen. Die so entstehende oszillierende Magnetisierung erzeugt Signale im Bereich von Radiofrequenzen (RF), die beispielweise mit Hilfe von elektrisch leitenden Schleifen, sogenannten Spulen, empfangen werden können. Seit den 90er Jahren werden Arrays solcher Empfangsspulen für die MRT benutzt. Ursprünglich wurden sie eingeführt, um das Signal-Rausch-Verhältnis (SNR) des empfangenen Signals zu steigern. Später wurden die Vorteile der Mehrkanal- Detektion durch Entwicklung der parallelen Bildgebung dazu genutzt, die Untersuchungszeit zu verkürzen. Neuere theoretische und experimentelle Arbeiten zeigen, dass zur optimalen Nutzung der Array- Detektion das Objekt von einer großen Zahl von kleinen Oberflächenspulen abgedeckt werden sollte. Ein optimales Ergebnis in Hinblick auf SNR mit einfacher Handhabung des Spulenarrays zu kombinieren wird jedoch umso schwieriger je grösser die Anzahl der Empfangsspulen ist. Das Ziel der vorliegenden Arbeit war es, Möglichkeiten zu untersuchen, diesen Herausforderungen zu begegnen. Dabei steht die Idee im Mittelpunkt, Empfangsspulenarrays für die MRT so zu konstruieren, dass sie sich durch Änderung der Grösse und Form der Spulenelemente und der Position der Spulenelemente relativ zueinander geometrisch an das Objekt anpassen können. Dadurch können die Spulen unabhängig von Form und Grösse des Objektes so nah wie möglich an der Oberfläche platziert und damit die Sensitivität gesteigert werden. Der zugrunde liegende Mechanismus muss sich einfach bedienen lassen und bequem für den Patienten sein. Geometrische Anpassungsfähigkeit führt aber auch im Zusammenhang mit der Elektronik, insbesondere in Bezug auf die Abstimmung der einzelnen Spulen, die Impedanzanpassung sowie die Rauscheigenschaften der Signalverstärkung zu einer Reihe von Herausforderungen. Zunächst wird eine neue Methode zur Charakterisierung der RFVorverstärker insbesondere im Hinblick auf deren Rauscheigenschaften vorgestellt. Die Impedanz am Eingang des Vorverstärkers kann sich bedingt durch unterschiedliche Beladung des Spulenarrays, Kopplung zwischen den Spulenelementen und verstärkte Wechselwirkungen zwischen Spulen und Objekt signifikant ändern. Da die Rauschzahl geeigneter Vorverstärker stark von der Impedanz am Eingang und der Messfrequenz abhängt, muss sie für verschiedene komplexe Impedanzen gemessen werden. Der Frequenzbereich reicht dabei von 42 MHz für klinische Niederfeldgeräte (1.0 T) bis zu 298 MHz für Forschungssysteme mit einer Feldstärke von 7.0 T. Dieser Frequenzbereich stellt eine der größten Herausforderungen dar, da Geräte für die Messung von Rauschzahlen wie beispielsweise Impedanz-Tuner für Frequenzen unterhalb von 500 MHz kommerziell nicht erhältlich sind. Dies liegt daran, dass solche Tuner in der Regel auf Transmission-Line-Technologie beruhen und damit nur schwer bei niedrigeren Frequenzen zu realisieren sind. Daher wurde eine andere Lösung entwickelt, die eine Halbleiterrauschquelle mit Netzwerken aus Widerständen, Kondensatoren und Spulen kombiniert. Dadurch entstehen Schaltungen variabler Impedanz und verstellbarer effektiver Rauschtemperatur. Die daraus resultierende Methode der Rauschzahlmessung wird sowohl durch die Übereinstimmung mit einem theoretischen Modell als auch durch MRT-basierte SNRMessungen überprüft. Als erster Schritt auf dem Weg zu anpassungsfähigen Empfangsspulenarrays wird der Bau eines mechanisch verstellbaren Arrays für MRT des Handgelenks bei 3.0 T beschrieben. Es kann sich Handgelenken unterschiedlicher Größe anpassen, indem der Abstand zwischen dem Handgelenk und den konisch angeordneten Elementen des Arrays verändert werden kann. Verschiedene Maßnahmen im Bereich des elektronischen Designs dieser Detektoren stellen sicher, dass trotz Veränderungen in der Beladung der Spulenelemente und der Kopplung untereinander, die sich aus der geometrischen Variabilität ergeben, gute Ergebnisse in robuster Art und Weise erzielt werden können. Mit Hilfe von SNR-Messungen in Abhängigkeit von der Impedanzanpassung, Messung unterschiedlich grosser Phantome sowie in-vivo Messungen von unterschiedlich großen Handgelenken werden die Vorteile dieses Ansatzes aufgezeigt. Das SNR von MRT-Experimenten skaliert etwa proportional zur Stärke des Hauptmagnetfeldes. Daher verspricht der Übergang von 3.0 T zu 7.0 T einen erheblichen Gewinn an Sensitivität, insbesondere für die Bildgebung des Handgelenks, das eine große Anzahl von kleinen, aber klinisch relevante Strukturen in einem kleinen Volumen vereint. Allerdings ist diese Vorhersage ist nicht einfach zu überprüfen. Eine der häufigsten Schwierigkeiten beim Vergleich von MRT bei verschiedenen Feldstärken ist die Tatsache, dass selten vergleichbare Spulenarrays auf beiden Systemen vorhanden sind. Um diesem Problem zu begegnen und die Vorteile der klinischen 7.0 T-Bildgebung des Handgelenkes im Vergleich zu 3.0 T zu untersuchen, wurde ein mechanisch verstellbares Spulenarray für MRT bei 7.0 T gebaut. Es ist geometrisch identisch mit der zuvor erwähnten Version für 3.0 T, jedoch im Bereich der Elektronik auf die grössere Resonanzfrequenz von 298 MHz bei 7.0 T angepasst. Die Handgelenke von 10 gesunden Probanden wurden nacheinander mit beiden Systemen gemessen und qualitativ von zwei unabhängigen Radiologen beurteilt. Die quantitative SNR-Analyse ergab ein bis zu 2-fach erhöhtes SNR bei 7.0 T im Vergleich zu 3.0 T. Allerdings hängt der SNR-Gewinn stark von der untersuchten Struktur und der Art des Gewebes ab. Die ultimative Lösung in Bezug auf die Anpassungsfähigkeit ist ein Spulenarray, dessen Elemente ihre Größe, Form und Anordnung durch Dehnung ändern und somit automatisch so nahe wie möglich an der Oberfläche des Objektes platziert werden. Das grundlegende Problem dieses Ansatzes, dehnbare elektrische Leiter mit genügend hoher Leitfähigkeit zu finden, wird durch die Verwendung metallischer Geflechte gelöst. Für einzelne Spulenelemente sowie für ein Spulenarray aus vier Elementen werden verschiedene Leitermaterialien sowie der Einfluss der Dehnung auf das SNR untersucht. Schliesslich wird die erfolgreiche Implementierung eines aus acht Spulenelementen bestehenden dehnbaren Arrays gezeigt. Dabei wurden zum ersten Mal Bilder bei verschiedenen Beugungswinkeln des Knies aufgenommen. Hierbei handelt es sich um eine vielversprechende orthopädische Anwendung, die sich mit den derzeitigen, starren Spulenarrays nicht realisieren lässt

    Noise figure characterization of preamplifiers at NMR frequencies

    Full text link
    A method for characterizing the noise figure of preamplifiers at NMR frequencies is presented. The noise figure of preamplifiers as used for NMR and MRI detection varies with source impedance and with the operating frequency. Therefore, to characterize a preamplifier's noise behavior, it is necessary to perform noise measurements at the targeted frequency while varying the source impedance with high accuracy. At high radiofrequencies, such impedance variation is typically achieved with transmission-line tuners, which however are not available for the relatively low range of typical NMR frequencies. To solve this issue, this work describes an alternative approach that relies on lumped-element circuits for impedance manipulation. It is shown that, using a fixed-impedance noise source and suitable ENR correction, this approach permits noise figure characterization for NMR and MRI purposes. The method is demonstrated for two preamplifiers, a generic BF998 MOSFET module and an MRI-dedicated, integrated preamplifier, which were both studied at 128MHz, i.e., at the Larmor frequency of protons at 3 Tesla. Variations in noise figure of 0.01dB or less over repeated measurements reflect high precision even for small noise figures in the order of 0.4dB. For validation, large sets of measured noise figure values are shown to be consistent with the general noise-parameter model of linear two-ports. Finally, the measured noise characteristics of the superior preamplifier are illustrated by SNR measurements in MRI data

    Do dynamic and static kinematics methods produce the same results?

    No full text
    MR-based methods provide low risk, non-invasive assessment of joint kinematics, however these methods often use static positions or require many identical cycles of movement. Study objectives were to develop a new 3D knee kinematic method requiring only a few cycles of motion (based on ultrafast gradient echo with water suppression), demonstrate the use of a novel 8-channel stretchable knee coil, and compare the results from this dynamic method to a 3D sequential static method, repeated using both a standard sequence and the new fast sequence.Ten normal volunteers were imaged using the three kinematic methods (dynamic, static standard, static fast). Results showed that the two sets of static results were in agreement, indicating the sequences (standard and fast) may be used interchangeably. Dynamic kinematic results were significantly different from both static results in eight of 11 kinematic parameters: patellar flexion, patellar tilt, patellar proximal translation, patellar lateral translation, patellar anterior translation, tibial abduction, tibial internal rotation, tibial anterior translation. Three-dimensional MR kinematics measured from dynamic knee motion are often different from those measured in a static knee at several positions, indicating that dynamic-based kinematics provides information that is not obtainable from static scans.Applied Science, Faculty ofMedicine, Faculty ofNon UBCMechanical Engineering, Department ofOrthopaedic Surgery, Department ofReviewedFacultyGraduateOthe

    MR imaging of healthy knees in varying degrees of flexion using a stretchable coil array provides comparable image quality compared to a standard knee coil array

    Full text link
    Objective: Stretchable coils allow knee imaging at varying degrees of flexion. Purpose was to compare a new-developed stretchable 8-channel to a standard 8-channel knee coil array by means of quantitative and qualitative image analysis. Material and methods: IRB approved prospective study. Knee MR imaging in 10 healthy volunteers was performed at 3T using a standard 8-channel and a new-developed stretchable 8-channel coil array at 0°, 45°, and 60° of flexion and at 0° (standard coil). Image parameters were identical. Signal-to-noise ratio (SNR) was determined by combining the images with separately acquired noise data on a pixel-by-pixel basis using MATLAB routines (Natick, MA, USA). Images were qualitatively analysed by two independent radiologists who graded the visibility of several anatomic structures from 1 = not visible to 5 = excellent. ANOVA, Wilcoxon and kappa statistics were used. Results: Mean SNR ± standarddeviation of bone was 54.7 ± 10.4 and of muscle 28.0 ± 4.4 using the stretchable coil array and 54.6 ± 8.2 and 33.4 ± 4.5, respectively, using the standard knee coil array. No statistically significant SNR differences were found between both arrays (bone, p = 0.960; muscle, p = 0.132). SNR was not degraded at higher degrees of flexion. The qualitative image analysis did not reveal statistically significant differences between the stretchable and standard coil array with regard to the visibility of anatomic structures (p = 0.026–1.000). Overall kappa was 0.714. Conclusion: Stretchable 8-channel coil arrays provide similar SNR and visibility of anatomic structures compared to standard 8-channel knee coil arrays. MR imaging with high SNR will now be possible in flexed knees

    Detection of GABA, Aspartate and Glutathione in the Human Spinal Cord

    No full text
    The aim of this investigation was to expand the number of predictive markers of in vivo MR spectroscopy measurements of the human spinal cord. Therefore, data was acquired in healthy volunteers with sophisticated motion and instability correction methods as well as advanced hardware enabling the acquisition with excellent spectral quality. Aspartate, Glutathione, and GABA could be additionally identified. In addition, for the first time, the findings were cross-validated with those retrieved from a cadaveric spinal cord sample using high resolution, magic angle spinning NMR measurements enabling a qualitative indication of the presence of the additional metabolite markers found in vivo

    Regulation of T cell survival through coronin-1-mediated generation of inositol-1,4,5-trisphosphate and calcium mobilization after T cell receptor triggering

    No full text
    T cell homeostasis is essential for the functioning of the vertebrate immune system, but the intracellular signals required for T cell homeostasis are largely unknown. We here report that the WD-repeat protein family member coronin-1, encoded by the gene Coro1a, is essential in the mouse for T cell survival through its promotion of Ca2+ mobilization from intracellular stores. Upon T cell receptor triggering, coronin-1 was essential for the generation of inositol-1,4,5-trisphosphate from phosphatidylinositol-4,5-bisphosphate. The absence of coronin-1, although it did not affect T cell development, resulted in a profound defect in Ca2+ mobilization, interleukin-2 production, T cell proliferation and T cell survival. We conclude that coronin-1, through activation of Ca2+ release from intracellular stores, is an essential regulator of peripheral lymphocyte survival

    COMBINED ADJUVANT RADIOCHEMOTHERAPY WITH IMRT/XELOX IMPROVES OUTCOME WITH LOW RENAL TOXICITY IN GASTRIC CANCER

    No full text
    Objectives: Adjuvant radiochemotherapy improves survival of patients with advanced gastric cancer. We assessed in two sequential cohorts whether improved radiotherapy technique (IMRT) together with intensified chemotherapy improves outcome vs. conventional three-dimensional conformal radiotherapy (3D-CRT) and standard chemotherapy in these patients while maintaining or reducing renal toxicity. Materials and Methods: Sixty consecutive patients treated for gastric cancer either with 3D-CRT (n = 27) and IMRT (n = 33) were evaluated. More than 70% had undergone D2 resection. Although there was a slight imbalance in R0 status between cohorts, N+ status was balanced. Chemotherapy consisted predominantly of 5-fluorouracil/folinic acid (it = 36) in the earlier cohort and mostly of oxali platin/capecitabine (XELOX, n = 24) in the later cohort. Primary end points were overall survival (OS), disease-free survival (DFS), and renal toxicity based on creatinine levels. Results: Median follow-up (FU) of all patients in the 3D-CRT group was 18 months and in the IMRT group 22 months (median FU of surviving patients 67 months in the 3D-CRT group and 25 months in the IMRT group). Overall median survival (and DFS) were 18 (13) months in the 3D-CRT group and both not reached in the IMRT group (p = 0.0492 and 0.0216). Actuarial 2-year survival was 37% and 67% in the 3D-CRT and IMRT groups, respectively. No late renal toxicity >Grade 2 (LENT-SOMA scale) was observed in either cohort. Conclusion: When comparing sequentially treated patient cohorts with similar characteristics, OS and DIPS improved with the use of IMRT and intensified chemotherapy without signs of increased renal toxicity. (C) 2009 Elsevier Inc

    Genetically controlled lysosomal entrapment of superparamagnetic ferritin for multimodal and multiscale imaging and actuation with low tissue attenuation.

    No full text
    Nanomaterials are of enormous value for biomedical applications because of their customizable features. However, the material properties of nanomaterials can be altered substantially by interactions with tissue thus making it important to assess them in the specific biological context to understand and tailor their effects. Here, a genetically controlled system is optimized for cellular uptake of superparamagnetic ferritin and subsequent trafficking to lysosomes. High local concentrations of photoabsorbing magnetoferritin give robust contrast in optoacoustic imaging and allow for selective photoablation of cells overexpressing ferritin receptors. Genetically controlled uptake of the biomagnetic nanoparticles also strongly enhances third-harmonic generation due to the change of refractive index caused by the magnetite-protein interface of ferritins entrapped in lysosomes. Selective uptake of magnetoferritin furthermore enables sensitive detection of receptor-expressing cells by magnetic resonance imaging, as well as efficient magnetic cell sorting and manipulation. Surprisingly, a substantial increase in the blocking temperature of lysosomally entrapped magnetoferritin is observed, which allows for specific ablation of genetically defined cell populations by local magnetic hyperthermia. The subcellular confinement of superparamagnetic ferritins thus enhances their physical properties to empower genetically controlled interrogation of cellular processes with deep tissue penetration
    corecore