34 research outputs found

    Cuprizone demyelination of the corpus callosum in mice correlates with altered social interaction and impaired bilateral sensorimotor coordination

    Get PDF
    For studies of remyelination in demyelinating diseases, the cuprizone model of CC (corpus callosum) demyelination has experimental advantages that include overall size, proximity to neural stem cells of the subventricular zone, and correlation with a lesion predilection site in multiple sclerosis. In addition, cuprizone treatment can be ended to allow more direct analysis of remyelination than with viral or autoimmune models. However, CC demyelination lacks a useful functional correlate in rodents for longitudinal analysis throughout the course of demyelination and remyelination. In the present study, we tested two distinct behavioural measurements in mice fed 0.2% cuprizone. Running on a ‘complex' wheel with varied rung intervals requires integration between cerebral hemispheres for rapid bilateral sensorimotor coordination. Maximum running velocity on the ‘complex' wheel decreased during acute (6 week) and chronic (12 week) cuprizone demyelination. Running velocity on the complex wheel distinguished treated (for 6 weeks) from non-treated mice, even after a 6-week recovery period for spontaneous remyelination. A second behavioural assessment was a resident–intruder test of social interaction. The frequency of interactive behaviours increased among resident mice after acute or chronic demyelination. Differences in both sensorimotor coordination and social interaction correlated with demonstrated CC demyelination. The wheel assay is applicable for longitudinal studies. The resident–intruder assay provides a complementary assessment of a distinct modality at a specific time point. These behavioural measurements are sufficiently robust for small cohorts as a non-invasive assessment of demyelination to facilitate analysis of subsequent remyelination. These measurements may also identify CC involvement in other mouse models of central nervous system injuries and disorders

    Effect of Inhaled Xenon on Cerebral White Matter Damage in Comatose Survivors of Out-of-Hospital Cardiac Arrest: A Randomized Clinical Trial

    Get PDF
    IMPORTANCE: Evidence from preclinical models indicates that xenon gas can prevent the development of cerebral damage after acute global hypoxic-ischemic brain injury but, thus far, these putative neuroprotective properties have not been reported in human studies. OBJECTIVE: To determine the effect of inhaled xenon on ischemic white matter damage assessed with magnetic resonance imaging (MRI). DESIGN, SETTING, AND PARTICIPANTS: A randomized single-blind phase 2 clinical drug trial conducted between August 2009 and March 2015 at 2 multipurpose intensive care units in Finland. One hundred ten comatose patients (aged 24-76 years) who had experienced out-of-hospital cardiac arrest were randomized. INTERVENTIONS: Patients were randomly assigned to receive either inhaled xenon combined with hypothermia (33°C) for 24 hours (n = 55 in the xenon group) or hypothermia treatment alone (n = 55 in the control group). MAIN OUTCOMES AND MEASURES: The primary end point was cerebral white matter damage as evaluated by fractional anisotropy from diffusion tensor MRI scheduled to be performed between 36 and 52 hours after cardiac arrest. Secondary end points included neurological outcome assessed using the modified Rankin Scale (score 0 [no symptoms] through 6 [death]) and mortality at 6 months. RESULTS: Among the 110 randomized patients (mean age, 61.5 years; 80 men [72.7%]), all completed the study. There were MRI data from 97 patients (88.2%) a median of 53 hours (interquartile range [IQR], 47-64 hours) after cardiac arrest. The mean global fractional anisotropy values were 0.433 (SD, 0.028) in the xenon group and 0.419 (SD, 0.033) in the control group. The age-, sex-, and site-adjusted mean global fractional anisotropy value was 3.8% higher (95% CI, 1.1%-6.4%) in the xenon group (adjusted mean difference, 0.016 [95% CI, 0.005-0.027], P = .006). At 6 months, 75 patients (68.2%) were alive. Secondary end points at 6 months did not reveal statistically significant differences between the groups. In ordinal analysis of the modified Rankin Scale, the median (IQR) value was 1 (1-6) in the xenon group and 1 (0-6) in the control group (median difference, 0 [95% CI, 0-0]; P = .68). The 6-month mortality rate was 27.3% (15/55) in the xenon group and 34.5% (19/55) in the control group (adjusted hazard ratio, 0.49 [95% CI, 0.23-1.01]; P = .053). CONCLUSIONS AND RELEVANCE: Among comatose survivors of out-of-hospital cardiac arrest, inhaled xenon combined with hypothermia compared with hypothermia alone resulted in less white matter damage as measured by fractional anisotropy of diffusion tensor MRI. However, there was no statistically significant difference in neurological outcomes or mortality at 6 months. These preliminary findings require further evaluation in an adequately powered clinical trial designed to assess clinical outcomes associated with inhaled xenon among survivors of out-of-hospital cardiac arrest. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00879892

    Cerebrospinal Fluid Metals and the Association with Cerebral Small Vessel Disease

    Get PDF
    BACKGROUND: Brain metal homeostasis is essential for brain health, and deregulation can result in oxidative stress on the brain parenchyma. OBJECTIVE: Our objective in this study was to focus on two hemorrhagic MRI manifestations of small vessel disease [cerebral microbleeds (CMBs) and cortical superficial siderosis (cSS)] and associations with cerebrospinal fluid (CSF) iron levels. In addition, we aimed to analyze CSF biomarkers for dementia and associations with CSF metal levels. METHODS: This is a cross-sectional study of 196 patients who underwent memory clinic investigation, including brain MRI. CSF was collected and analyzed for metals, amyloid-β (Aβ) 42, total tau (T-tau), and phosphorylated tau (P-tau), and CSF/serum albumin ratios. Statistical analyses were performed using generalized linear models. RESULTS: No significant difference was found between CSF metal levels across diagnostic groups. Higher iron and copper levels were associated with higher CSF levels of Aβ42, T-tau, P-tau, and CSF/serum albumin ratios (p < 0.05). Zinc was associated with higher CSF/serum albumin ratios. There was no significant association between CMBs or cSS and CSF iron levels. An increase in CSF iron with the number of CMBs was seen in APOEɛ4 carriers. CONCLUSION: CSF iron levels are elevated with cerebral microbleeds in APOEɛ4 carriers, with no other association seen with hemorrhagic markers of small vessel disease. The association of elevated CSF iron and copper with tau could represent findings of increased neurodegeneration in these patients

    Comparison of Manual Cross-Sectional Measurements and Automatic Volumetry of the Corpus Callosum, and Their Clinical Impact: A Study on Type 1 Diabetes and Healthy Controls

    Get PDF
    Manually measured callosal area and automatically segmented are interchangeable. The association seen between callosal size with cerebral microbleeds and insulin resistance is indicative of small vessel disease pathology in diabetes type 1

    Contour identical implants to bridge mandibular continuity defects - individually generated by LaserCUSING® - A feasibility study in animal cadavers

    Get PDF
    Background Ablative tumor surgery often results in continuity defects of the mandible. When an immediate reconstruction using autologous bone grafts is not possible the bridging of the defects with a variety of bridging plates might be achieved. However, those bridging plates have the risk of plate fractures or exposure. Customized titanium implants manufactured using CAD/CAM and the LaserCUSING® technique might be an alternative. Methods In the present study, computed tomographies (CT) of porcine cadaver mandibles were generated and transferred into DICOM data. Following, different continuity defects were surgically created in the mandibles. Based on the DICOM data customized titanium implants were manufactured using CAD/CAM procedures and the LaserCUSING® technique. The implants were fixed to the remaining stumps with screws. Subsequently, the accuracy of the reconstructed mandibles was tested using plaster casts. Results The workflow from the CT to the application of the customized implants was proved to be practicable. Furthermore, a stable fixation of the customized implant to the remaining stumps could be achieved. The control of the accuracy showed no frictions or obstacles. Conclusion The customized titanium implant seems to be a promising approach to bridge continuity defects of the mandible whenever an immediate reconstruction with autologous bone is not possible

    APOE epsilon 4 associates with increased risk of severe COVID-19, cerebral microhaemorrhages and post-COVID mental fatigue : a Finnish biobank, autopsy and clinical study

    Get PDF
    Apolipoprotein E epsilon 4 allele (APOE4) has been shown to associate with increased susceptibility to SARS-CoV-2 infection and COVID-19 mortality in some previous genetic studies, but information on the role of APOE4 on the underlying pathology and parallel clinical manifestations is scarce. Here we studied the genetic association between APOE and COVID-19 in Finnish biobank, autopsy and prospective clinical cohort datasets. In line with previous work, our data on 2611 cases showed that APOE4 carriership associates with severe COVID-19 in intensive care patients compared with non-infected population controls after matching for age, sex and cardiovascular disease status. Histopathological examination of brain autopsy material of 21 COVID-19 cases provided evidence that perivascular microhaemorrhages are more prevalent in APOE4 carriers. Finally, our analysis of post-COVID fatigue in a prospective clinical cohort of 156 subjects revealed that APOE4 carriership independently associates with higher mental fatigue compared to non-carriers at six months after initial illness. In conclusion, the present data on Finns suggests that APOE4 is a risk factor for severe COVID-19 and post-COVID mental fatigue and provides the first indication that some of this effect could be mediated via increased cerebrovascular damage. Further studies in larger cohorts and animal models are warranted.Peer reviewe

    Comparison of the prognostic value of early-phase proton magnetic resonance spectroscopy and diffusion tensor imaging with serum neuron-specific enolase at 72 h in comatose survivors of out-of-hospital cardiac arrest-a substudy of the XeHypotheca trial

    Get PDF
    Purpose: We compared the predictive accuracy of early-phase brain diffusion tensor imaging (DTI), proton magnetic resonance spectroscopy (1H-MRS), and serum neuron-specific enolase (NSE) against the motor score and epileptic seizures (ES) for poor neurological outcome after out-of-hospital cardiac arrest (OHCA).Methods: The predictive accuracy of DTI, 1H-MRS, and NSE along with motor score at 72 h and ES for the poor neurological outcome (modified Rankin Scale, mRS, 3 - 6) in 92 comatose OHCA patients at 6 months was assessed by area under the receiver operating characteristic curve (AUROC). Combined models of the variables were included as exploratory.Results: The predictive accuracy of fractional anisotropy (FA) of DTI (AUROC 0.73, 95% CI 0.62-0.84), total N-acetyl aspartate/total creatine (tNAA/tCr) of 1H-MRS (0.78 (0.68 - 0.88)), or NSE at 72 h (0.85 (0.76 - 0.93)) was not significantly better than motor score at 72 h (0.88 (95% CI 0.80-0.96)). The addition of FA and tNAA/tCr to a combination of NSE, motor score, and ES provided a small but statistically significant improvement in predictive accuracy (AUROC 0.92 (0.85-0.98) vs 0.98 (0.96-1.00), p = 0.037).Conclusion: None of the variables (FA, tNAA/tCr, ES, NSE at 72 h, and motor score at 72 h) differed significantly in predicting poor outcomes in this patient group. Early-phase quantitative neuroimaging provided a statistically significant improvement for the predictive value when combined with ES and motor score with or without NSE. However, in clinical practice, the additional value is small, and considering the costs and challenges of imaging in this patient group, early-phase DTI/MRS cannot be recommended for routine use.</p
    corecore