279 research outputs found

    Antioxidant properties of minimally processed (ready-to-eat) Italian Cichorium genus salads

    Get PDF
    The modern lifestyle is characterized by a continuous increase in the demand of ready-to-eat fresh food products subjected to minimal processes prior marketing. Attention is drawn towards the effect of this processing on the antioxidant/antiradical properties of two typical Italian salads belonging to Cichorium genus. Four chemical assays (anti-peroxyl radical activity, DPPH• assay, metal chelating ability assay, and reducing power assay) were used for evaluating these properties. The results indicated that the anti-peroxyl radical activity, the anti-DPPH radical activity, the metal chelating ability, and the reducing power were significantly higher in fresh samples as compared to 8-days stored samples (p<0.001). Minimal processing applied to vegetables further affected the tested properties causing a decrease over time from 24h to 8d of storage at 4°C. Overall, the results presented in this study showed that any minimal processing applied to ready-to-eat vegetable affects the antioxidant/antiradical properties determining a decrease in the values registered in the four chemical assays

    Liquid phase microextraction techniques combined with chromatography analysis: A review

    Get PDF
    Sample pretreatment is the first and the most important step of an analytical procedure. In routine analysis, liquid-liquid microextraction (LLE) is the most widely used sample pre-treatment technique, whose goal is to isolate the target analytes, provide enrichment, with cleanup to lower the chemical noise, and enhance the signal. The use of extensive volumes of hazardous organic solvents and production of large amounts of waste make LLE procedures unsuitable for modern, highly automated laboratories, expensive, and environmentally unfriendly. In the past two decades, liquid-phase microextraction (LPME) was introduced to overcome these drawbacks. Thanks to the need of only a few microliters of extraction solvent, LPME techniques have been widely adopted by the scientific community. The aim of this review is to report on the state-of-the-art LPME techniques used in gas and liquid chromatography. Attention was paid to the classification of the LPME operating modes, to the historical contextualization of LPME applications, and to the advantages of microextraction in methods respecting the value of green analytical chemistry. Technical aspects such as description of methodology selected in method development for routine use, specific variants of LPME developed for complex matrices, derivatization, and enrichment techniques are also discussed

    Solid phase microextraction techniques used for gas chromatography: A review

    Get PDF
    In the last decade, the development and adoption of greener and sustainable microextraction techniques have been proved to be an effective alternative to classical sample preparation procedures. In this review, 10 commercially available solid-phase microextraction systems are presented, with special attention to the appraisal of their analytical, bioanalytical, and environmental engineering. This review provides an overview of the challenges and achievements in the application of fully automated miniaturized sample preparation methods in analytical laboratories. Both theoretical and practical aspects of these environment-friendly preparation approaches are discussed. The application of chemometrics in method development is also discussed. We are convinced that green analytical chemistry will be really useful in the years ahead. The application of cheap, fast, automated, clever , and environmentally safe procedures to environmental, clinical, and food analysis will improve significantly the quality of the analytical data

    Immobilization of γ-Glutamyl Transpeptidase from Equine Kidney for the Synthesis of Kokumi Compounds

    Get PDF
    γ-Glutamyl transpeptidase from equine kidney (ekGGT, E.C. 2.3.2.2) is an intrinsic membrane enzyme which transfers the γ-glutamyl moiety of glutathione to amino acids and peptides, thus producing γ-glutamyl derivatives. An immobilization study of ekGGT was carried out with the aim to develop a robust biocatalyst for the synthesis of γ-glutamyl amino acids which are known as kokumi compounds. Heterofunctional octyl-glyoxyl-agarose resulted in a high immobilization yield and activity recovery (93 % and 88 %, respectively). Immobilized ekGGT retained more than 95 % activity under reaction conditions (Tris-HCl, pH 9, 0.05 M) after 6 days, whereas the residual activity after 6 reaction cycles (18 days) was 85 %. The synthesis of γ-glutamylmethionine catalyzed by octyl-glyoxyl-agarose-ekGGT afforded the product in 42 % yield (101 mg). The immobilized ekGGT was characterized by Raman spectroscopy. The immobilization protocol developed for ekGGT could be of general applicability to membrane proteins

    Immobilization of γ-Glutamyl Transpeptidase from Equine Kidney for the Synthesis of kokumi Compounds

    Get PDF
    \u3b3-Glutamyl transpeptidase from equine kidney (ekGGT, E.C. 2.3.2.2) is an intrinsic membrane enzyme which transfers the \u3b3-glutamyl moiety of glutathione to amino acids and peptides, thus producing \u3b3-glutamyl derivatives. An immobilization study of ekGGT was carried out with the aim to develop a robust biocatalyst for the synthesis of \u3b3-glutamyl amino acids which are known as kokumi compounds. Heterofunctional octyl-glyoxyl-agarose resulted in a high immobilization yield and activity recovery (93 % and 88 %, respectively). Immobilized ekGGT retained more than 95 % activity under reaction conditions (Tris-HCl, pH 9, 0.05 M) after 6 days, whereas the residual activity after 6 reaction cycles (18 days) was 85 %. The synthesis of \u3b3-glutamylmethionine catalyzed by octyl-glyoxyl-agarose-ekGGT afforded the product in 42 % yield (101 mg). The immobilized ekGGT was characterized by Raman spectroscopy. The immobilization protocol developed for ekGGT could be of general applicability to membrane proteins

    Performance of the ForenSeqTM DNA Signature Prep kit on highly degraded samples

    Get PDF
    Next generation sequencing (NGS) is the emerging technology in forensic genomics laboratories. It offers higher resolution to address most problems of human identification, greater efficiency and potential ability to interrogate very challenging forensic casework samples. In this study, a trial set of DNA samples was artificially degraded by progressive aqueous hydrolysis, and analyzed together with the corresponding unmodified DNA sample and control sample 2800 M, to test the performance and reliability of the ForenSeqTM DNA Signature Prep kit using the MiSeq Sequencer (Illumina). The results of replicate tests performed on the unmodified sample (1.0 ng) and on scalar dilutions (1.0, 0.5 and 0.1 ng) of the reference sample 2800 M showed the robustness and the reliability of the NGS approach even from sub-optimal amounts of high quality DNA. The degraded samples showed a very limited number of reads/sample, from 2.9\u201310.2 folds lower than the ones reported for the less concentrated 2800 M DNA dilution (0.1 ng). In addition, it was impossible to assign up to 78.2% of the genotypes in the degraded samples as the software identified the corresponding loci as \u201clow coverage\u201d ( 50x). Amplification artifacts such as allelic imbalances, allele drop outs and a single allele drop in were also scored in the degraded samples. However, the ForenSeqTM DNA Sequencing kit, on the Illumina MiSeq, was able to generate data which led to the correct typing of 5.1\u201344.8% and 10.9\u201358.7% of 58 of the STRs and 92 SNPs, respectively. In all trial samples, the SNP markers showed higher chances to be typed correctly compared to the STRs. This NGS approach showed very promising results in terms of ability to recover genetic information from heavily degraded DNA samples for which the conventional PCR/CE approach gave no results. The frequency of genetic mistyping was very low, reaching the value of 1.4% for only one of the degraded samples. However, these results suggest that further validation studies and a definition of interpretation criteria for NGS data are needed before implementation of this technique in forensic genetics

    liquid phase microextraction techniques combined with chromatography analysis a review

    Get PDF
    Sample pretreatment is the first and the most important step of an analytical procedure. In routine analysis, liquid–liquid microextraction (LLE) is the most widely used sample pre-treatment technique, whose goal is to isolate the target analytes, provide enrichment, with cleanup to lower the chemical noise, and enhance the signal. The use of extensive volumes of hazardous organic solvents and production of large amounts of waste make LLE procedures unsuitable for modern, highly automated laboratories, expensive, and environmentally unfriendly. In the past two decades, liquid-phase microextraction (LPME) was introduced to overcome these drawbacks. Thanks to the need of only a few microliters of extraction solvent, LPME techniques have been widely adopted by the scientific community. The aim of this review is to report on the state-of-the-art LPME techniques used in gas and liquid chromatography. Attention was paid to the classification of the LPME operating modes, to the historical contextualization of LPME applications, and to the advantages of microextraction in methods respecting the value of green analytical chemistry. Technical aspects such as description of methodology selected in method development for routine use, specific variants of LPME developed for complex matrices, derivatization, and enrichment techniques are also discussed

    Monitoring of air-dispersed formaldehyde and carbonyl compounds as vapors and adsorbed on particulate matter by denuder-filter sampling and gas chromatographic analysis

    Get PDF
    Carbonyl compounds (CCs) are products present both as vapors and as condensed species adsorbed on the carbonaceous particle matter dispersed in the air of urban areas, due to vehicular traffic and human activities. Chronic exposure to CCs is a potential health risk given the toxicity of these chemicals. The present study reports on the measurement of the concentrations of 14 CCs in air as vapors and 2.5 µm fraction PM by the ENVINT GAS08/16 gas/aerosol sampler, a serial sampler that uses annular denuder, as sampling device. The 14 CCs were derivatized during sampling prior to gas-chromatographic separation and multiple detection by mass spectrometry, nitrogen-phosphorus thermionic, electron capture detection. Outdoor air multiple samples were collected in four locations in the urban area of Florence. The results evidenced that formaldehyde, acetaldehyde, and acetone were the more abundant CCs in the studied areas. The data collected was discussed considering the particle to vapor ratio of each CC found. The CCs pollution picture obtained was tentatively related to the nature and intensity of the traffic transiting by the sampling sites. This approach allowed to determine 14 CCs in both concentrated and diluted samples and is proposed as a tool for investigating outdoor and indoor pollution

    Solid phase microextraction techniques used for gas chromatography: A review

    Get PDF
    In the last decade, the development and adoption of greener and sustainable microextraction techniques have been proved to be an effective alternative to classical sample preparation procedures. In this review, 10 commercially available solid-phase microextraction systems are presented, with special attention to the appraisal of their analytical, bioanalytical, and environmental engineering. This review provides an overview of the challenges and achievements in the application of fully automated miniaturized sample preparation methods in analytical laboratories. Both theoretical and practical aspects of these environment-friendly preparation approaches are discussed. The application of chemometrics in method development is also discussed. We are convinced that green analytical chemistry will be really useful in the years ahead. The application of cheap, fast, automated, "clever", and environmentally safe procedures to environmental, clinical, and food analysis will improve significantly the quality of the analytical data
    • …
    corecore