55 research outputs found

    Neutrino physics with multi-ton scale liquid xenon detectors

    Get PDF
    We study the sensitivity of large-scale xenon detectors to low-energy solar neutrinos, to coherent neutrino-nucleus scattering and to neutrinoless double beta decay. As a concrete example, we consider the xenon part of the proposed DARWIN (Dark Matter WIMP Search with Noble Liquids) experiment. We perform detailed Monte Carlo simulations of the expected backgrounds, considering realistic energy resolutions and thresholds in the detector. In a low-energy window of 2-30 keV, where the sensitivity to solar pp and 7^7Be-neutrinos is highest, an integrated pp-neutrino rate of 5900 events can be reached in a fiducial mass of 14 tons of natural xenon, after 5 years of data. The pp-neutrino flux could thus be measured with a statistical uncertainty around 1%, reaching the precision of solar model predictions. These low-energy solar neutrinos will be the limiting background to the dark matter search channel for WIMP-nucleon cross sections below ∼\sim2×\times10−48^{-48} cm2^2 and WIMP masses around 50 GeV⋅\cdotc−2^{-2}, for an assumed 99.5% rejection of electronic recoils due to elastic neutrino-electron scatters. Nuclear recoils from coherent scattering of solar neutrinos will limit the sensitivity to WIMP masses below ∼\sim6 GeV⋅\cdotc−2^{-2} to cross sections above ∼\sim4×\times10−45^{-45}cm2^2. DARWIN could reach a competitive half-life sensitivity of 5.6×\times1026^{26} y to the neutrinoless double beta decay of 136^{136}Xe after 5 years of data, using 6 tons of natural xenon in the central detector region.Comment: 17 pages, 4 figure

    Fluorescence decay-time constants in organic liquid scintillators

    Full text link
    The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector LENA (Low Energy Neutrino Astronomy). In particular, the impact of the measured values to the search for proton decay via p -> K+ antineutrino is evaluated in this work.Comment: 7 pages, 5 figure

    Spectroscopy of electron-induced fluorescence in organic liquid scintillators

    Full text link
    Emission spectra of several organic liquid-scintillator mixtures which are relevant for the proposed LENA detector have been measured by exciting the medium with electrons of ~10keV. The results are compared with spectra resulting from ultraviolet light excitation. Good agreement between spectra measured by both methods has been found.Comment: 6 pages, 7 figure

    Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr

    Full text link
    A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived 83m-Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67E-6 events/kg/day in the next generation of LXe dark matter direct detection searchesComment: 9 pages, 9 figures. Accepted to Review of Scientific Instrument

    Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector

    Full text link
    The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for XENON1T, of which the impact on the detector performance is discussed. All photomultipliers have been tested in a nitrogen atmosphere at cryogenic temperatures, with a subset of the tubes being tested in gaseous and liquid xenon, simulating their operating conditions in the dark matter detector. The performance and evaluation of the tubes in the different environments is reported and the criteria for rejection of PMTs are outlined and quantified.Comment: 24 pages, 16 figure

    Searching for prompt signatures of nearby core-collapse supernovae by a joint analysis of neutrino and gravitational-wave data

    Get PDF
    We discuss the science motivations and prospects for a joint analysis of gravitational-wave (GW) and low-energy neutrino data to search for prompt signals from nearby supernovae (SNe). Both gravitational-wave and low-energy neutrinos are expected to be produced in the innermost region of a core-collapse supernova, and a search for coincident signals would probe the processes which power a supernova explosion. It is estimated that the current generation of neutrino and gravitational-wave detectors would be sensitive to Galactic core-collapse supernovae, and would also be able to detect electromagnetically dark SNe. A joint GW-neutrino search would enable improvements to searches by way of lower detection thresholds, larger distance range, better live-time coverage by a network of GW and neutrino detectors, and increased significance of candidate detections. A close collaboration between the GW and neutrino communities for such a search will thus go far toward realizing a much sought-after astrophysics goal of detecting the next nearby supernova.Comment: 10 pages, 3 figures. To appear in Class. Quantum Gra

    The LAGUNA design study- towards giant liquid based underground detectors for neutrino physics and astrophysics and proton decay searches

    Get PDF
    The feasibility of a next generation neutrino observatory in Europe is being considered within the LAGUNA design study. To accommodate giant neutrino detectors and shield them from cosmic rays, a new very large underground infrastructure is required. Seven potential candidate sites in different parts of Europe and at several distances from CERN are being studied: Boulby (UK), Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland), Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The design study aims at the comprehensive and coordinated technical assessment of each site, at a coherent cost estimation, and at a prioritization of the sites within the summer 2010.Comment: 5 pages, contribution to the Workshop "European Strategy for Future Neutrino Physics", CERN, Oct. 200

    Dark Matter Results from 100 Live Days of XENON100 Data

    Full text link
    We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.Comment: 5 pages, 5 figures; matches accepted versio

    Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"

    Full text link
    In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.Comment: 3 pages, no figure

    Development and evaluation of a rapid dipstick assay for serodiagnosis of acute human brucellosis

    Get PDF
    A dipstick assay for the detection of brucella-specific immunoglobulin M antibodies was evaluated with 707 sera from 247 laboratory-confirmed brucellosis patients and 342 control sera from brucellosis-free individuals. These sera were collected from six different countries. The assay was found to be highly sensitive and specific. In addition, the test is easy to use and does not require specialized training or equipment, and the components are stable without a requirement for refrigeration. All of these factors make the test ideal for developing countries and rural settings
    • …
    corecore