23 research outputs found

    Electrical stimulator with mechanomyography-based real-time monitoring, muscle fatigue detection, and safety shut-off: a pilot study

    Get PDF
    Functional electrical stimulation (FES) has been used to produce force-related activities on the paralyzed muscle among spinal cord injury (SCI) individuals. Early muscle fatigue is an issue in all FES applications. If not properly monitored, overstimulation can occur, which can lead to muscle damage. A real-Time mechanomyography (MMG)-based FES system was implemented on the quadriceps muscles of three individuals with SCI to generate an isometric force on both legs. Three threshold drop levels of MMG-root mean square (MMG-RMS) feature (thr50, thr60, and thr70; representing 50%, 60%, and 70% drop from initial MMG-RMS values, respectively) were used to terminate the stimulation session. The mean stimulation time increased when the MMG-RMS drop threshold increased (thr50: 22.7 s, thr60: 25.7 s, and thr70: 27.3 s), indicating longer sessions when lower performance drop was allowed. Moreover, at thr70, the torque dropped below 50% from the initial value in 14 trials, more than at thr50 and thr60. This is a clear indication of muscle fatigue detection using the MMG-RMS value. The stimulation time at thr70 was significantly longer (p = 0.013) than that at thr50. The results demonstrated that a real-Time MMG-based FES monitoring system has the potential to prevent the onset of critical muscle fatigue in individuals with SCI in prolonged FES sessions

    A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats.

    Get PDF
    Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0-20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01-200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system

    FES in Europe and beyond: Current Translational Research

    Get PDF
    Capacity of adult neural and muscle tissues to respond to external Electrical Stimulation (ES) is the biological basis for the development and implementation of mobility impairment physiotherapy protocols and of related assistive technologies, e.g, Functional Electrical Stimulation (FES). All body tissues, however, respond to electrical stimulation and, indeed, the most successful application of FES is electrical stimulation of the heart to revert or limit effects of arrhythmias (Pace-makers and Defibrillators). Here, we list and discuss results of FES current research activities, in particular those presented at 2016 Meetings: the PaduaMuscleDays, the Italian Institute of Myology Meeting, the 20th International Functional Electrical Stimulation Society (IFESS) conference held in Montpellier and the Vienna Workshop on FES. Several papers were recently e-published in the European Journal of Translational Myology as reports of meeting presentations. All the events and publications clearly show that FES research in Europe and beyond is alive and promisses translation of results into clinical management of a very large population of persons with deficiencies

    Mechanomyography-based muscle fatigue detection during electrically elicited cycling in patients with spinal cord injury

    Get PDF
    Patients with spinal cord injury (SCI) benefit from muscle training with functional electrical stimulation (FES). For safety reasons and to optimize training outcome, the fatigue state of the target muscle must be monitored. Detection of muscle fatigue from mel frequency cepstral coefficient (MFCC) feature of mechanomyographic (MMG) signal using support vector machine (SVM) classifier is a promising new approach. Five individuals with SCI performed FES cycling exercises for 30 min. MMG signals were recorded on the quadriceps muscle group (rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM)) and categorized into non-fatigued and fatigued muscle contractions for the first and last 10 min of the cycling session. For each subject, a total of 1800 contraction-related MMG signals were used to train the SVM classifier and another 300 signals were used for testing. The average classification accuracy (4-fold) of non-fatigued and fatigued state was 90.7% using MFCC feature, 74.5% using root mean square (RMS), and 88.8% with combined MFCC and RMS features. Inter-subject prediction accuracy suggested training and testing data to be based on a particular subject or large collection of subjects to improve fatigue prediction capacity. [Figure not available: see fulltext.]. © 2019, International Federation for Medical and Biological Engineering

    The Vienna FES Interview Protocol – A mixed-methods protocol to elucidate the opinions of various individuals responsible for the provision of FES exercise

    No full text
    Functional Electrical Stimulation (FES) is the production of electrically elicited muscle contractions to perform a function or task. It has been used as a method to regain lost body functions or support weak body functions, and as such, has been clinically available since the early seventies. Some methods are applied routinely while others have not been translated to the bedside, or are still largely restricted to laboratory use. Progress in this field might be achieved by a strong cooperation of patients, clinicians, therapists and engineers. A better insight into multiple perspectives may help in understanding the shortcomings of current FES technology. This will help direct future research efforts into design of systems and potential application in relevant populations. In addition, these findings can assist with the translation of FES technology into a community context. We outline an interview protocol designed for use at the 12th Vienna International Workshop on Functional Electrical Stimulation where the mentioned experts from the field of FES met

    Adaptation of the transcriptional response to resistance exercise over 4 weeks of daily training

    No full text
    We present the time course of change in the muscle transcriptome 1 h after the last exercise bout of a daily resistance training program lasting 2, 10, 20, or 30 days. Daily exercise in rat tibialis anterior muscles (5 sets of 10 repetitions over 20 min) induced progressive muscle growth that approached a new stable state after 30 days. The acute transcriptional response changed along with progressive adaptation of the muscle phenotype. For example, expression of type 2B myosin was silenced. Time courses recently synthesized from human exercise studies do not demonstrate so clearly the interplay between the acute exercise response and the longer-term consequences of repeated exercise. We highlight classes of transcripts and transcription factors whose expression increases during the growth phase and declines again as the muscle adapts to a new daily pattern of activity and reduces its rate of growth. Myc appears to play a central role

    Stress matters! Psychophysiological and emotional loadings of pregnant women undergoing fetal magnetic resonance imaging

    No full text
    Background While the application of fetal MRI in high-risk pregnant women is steadily rising, little is known about the psychological consequences of this procedure. The aim of the present study was to investigate emotional and psychophysiological reactions of females undergoing fetal MRI. Methods Sixty women (1744 ys), assigned for fetal MRI, were included. Affective state was assessed by standardized measures of anxiety, emotional states and depressive symptoms. Stress coping strategies were assessed using a self-report questionnaire. Stress responses were determined using skin conductance levels (SCL) during fetal MRI as well as measurement of salivary cortisol levels immediately before and after fetal MRI. Results Analysis of fast and slow physiological stress measures revealed significant differences between women with and without a supporting person accompanying them to the examination. For SCLs, lower levels of stress during MRI emerged in accompanied women. Women with well-marked stress-coping-strategies experienced lower levels of stress during the examination. Although fast and slow stress measures before and after MRI did not show significant correlations, a significant difference of SCLs pre and post examination was clearly detectable, as well as a trend of decreased cortisol levels for both time points. Conclusions The results imply that the elevation of SCLs is an accurate instrument to assess fast stress alterations in patients during fetal MRI. Stress coping strategies and whether women are accompanied or not play an important role in the experience of anxiety and depressive symptoms. These factors should be considered especially in patients with high-risk-pregnancies to improve patient care.(VLID)486401

    Frequency response.

    No full text
    <p>Frequency attenuation of the signals measured with the reference-sensor (dark grey trace) and the load-cell (black trace), in combination with the attenuation predicted by the calculated model of the load-cell (light grey trace). The model fits the measured load-cell data well at lower frequencies. For frequencies higher than 10 Hz a further decrease is observed in the measured data, revealing a maximal attenuation of -4.2 dB at a frequency of 200 Hz.</p
    corecore