34 research outputs found

    Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes

    Get PDF
    Objectives: Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. Methods: Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. Results: Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. Conclusions: MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. Key Points: • Postoperative MDCT presents baseline morphology relevant for prosthetic valve follow-up. • 83 % of patients show periaortic induration 6 weeks after aortic valve replacement. • MDCT detected three cases of clinically relevant pathology not found with TTE. • Valve dehiscence detection by MDCT required redo valve surgery in one patient. • MDCT is a suitable and complementary imaging tool for follow-up purposes

    Вивчення процесу синтезу нанокристалічних плівок двооксиду титану в розряді магнетронного типу за його оптичними та плазмодинамічними характеристиками

    Get PDF
    Наведено результати експериментального дослiдження плазмодинамiчних i оптичних характеристик цилiндричного газового розряду магнетронного типу в умовах безперервного контролю спектра, випромiнюваного плазмою в дiапазонi 350–820 нм. Визначено умови для синтезу бiнарної сполуки TiО₂, якi забезпечуються пiдтримкою величини iнтенсивностi спектральних лiнiй реагуючих компонентiв i плазмоутворюючого газу. Розглянуто можливiсть контролю умов одержання плiвок TiО₂ як по спектральних характеристиках плазми розряду, так i по змiнi розрядної напруги. Елiпсометричнi дослiдження нанокристалiчних плiвок двооксиду титану показали наявнiсть залежностi показника переломлення вiд товщини плiвки.We present the results of experimental researches of plasmodynamic and optical characteristics of a magnetron-type cylindrical gas discharge. The study was carried out provided a permanent monitoring of the spectrum emitted by plasma in the range 350–820 nm. For the synthesis of binary compound TiO₂, we have determined conditions which can be ensured by a support of the intensity of spectral lines emitted by reacting components and plasma-forming gas. A possibility to control the conditions of the fabrication of a TiO₂ film with the use of both the spectral characteristics of a discharge plasma and a variation of the discharge voltage has been analyzed. Ellipsometric and spectral studies of nanocrystalline titanium dioxide films revealed the dependence of the refractive index of a film on the film thickness.Приведены результаты экспериментального исследования плазмодинамических и оптических характеристик цилиндрического газового разряда магнетронного типа в условиях непрерывного контроля спектра, излучаемого плазмой в диапазоне 350–820 нм. Определены условия для синтеза бинарного соединения TiО₂, которые обеспечиваются поддержанием величины интенсивности спектральных линий реагирующих компонент и плазмообразующего газа. Рассмотрена возможность контроля условий получения пленок TiO₂ как по спектральным характеристикам плазмы разряда, так и по изменению разрядного напряжения. Эллипсометрические и спектральные исследования нанокристаллических пленок диоксида титана показали наличие зависимости показателя преломления от толщины пленки

    Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    Get PDF
    Objectives: Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Methods: Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis

    Effect of balloon angioplasty in femoropopliteal arteries assessed by intravascular ultrasound

    Get PDF
    Objective: To study the effects of balloon angioplasty (PTA) of the femoropopliteal artery with intravascular ultrasound (IVUS). Materials and methods: Corresponding IVUS cross-sections (n = 1033) obtained before and after PTA from 115 procedures were analysed. Vascular damage including plaque rupture, dissection and media rupture was assessed. Free lumen area (FLA), media-bounded area (MBA) and plaque area (PLA) were measured. Results: After PTA vascular damage was seen at the target site in 83 (72%) arteries: plaque rupture in 30 (26%), dissection in 66 (57%) and media rupture in 20 (17%) arteries. The FLA increased from 5.4 ± 3.4 mm2 to 14.1 ± 5.0 mm2 (p < 0.001), MBA increased from 26.9 ± 10.0 mm2 to 32.9 ± 10.7 mm2 (p < 0.001) and PLA decreased from 21.6 ± 8.5 mm2 to 18.8 ± 8.0 mm2 (p < 0.001). The increase in MBA accounted for 68% of lumen gain. The frequency of vascular damage and the relative contribution of MBA increase and PLA decrease to luminal gain were not different in procedures with balloon diameter ≤ 5 mm and ≤ 6 mm. Conclusions: Vascular damage is common following PTA. Lumen gain is mainly due to vessel expansion and, to a lesser extent, to a decrease in plaque area

    Ischemic brain lesions after carotid artery stenting increase future cerebrovascular risk

    Get PDF
    Background Brain lesions on diffusion-weighted imaging (DWI) are frequently found after carotid artery stenting (CAS), but their clinical relevance remains unclear. Objectives This study sought to investigate whether periprocedural ischemic DWI lesions after CAS or carotid endarterectomy (CEA) are associated with an increased risk of recurrent cerebrovascular events. Methods In the magnetic resonance imaging (MRI) substudy of ICSS (International Carotid Stenting Study), 231 patients with symptomatic carotid stenosis were randomized to undergo CAS (n = 124) or CEA (n = 107). MRIs were performed 1 to 7 days before and 1 to 3 days after treatment. The primary outcome event was stroke or transient ischemic attack in any territory occurring between the post-treatment MRI and the end of follow-up. Time to occurrence of the primary outcome event was compared between patients with (DWI+) and without (DWI-) new DWI lesions on the post-treatment scan in the CAS and CEA groups separately. Results Median time of follow-up was 4.1 years (interquartile range: 3.0 to 5.2). In the CAS group, recurrent stroke or transient ischemic attack occurred more often among DWI+ patients (12 of 62) than among DWI- patients (6 of 62), with a cumulative 5-year incidence of 22.8% (standard error [SE]: 7.1%) and 8.8% (SE: 3.8%), respectively (unadjusted hazard ratio: 2.85; 95% confidence interval: 1.05 to 7.72; p = 0.04). In DWI+ and DWI- patients, 8 and 2 events, respectively, occurred within 6 months after treatment. In the CEA group, there was no difference in recurrent cerebrovascular events between DWI+ and DWI- patients. Conclusions Ischemic brain lesions discovered on DWI after CAS seem to be a marker of increased risk for recurrent cerebrovascular events. Patients with periprocedural DWI lesions might benefit from more aggressive and prolonged antiplatelet therapy after CAS. (A Randomised Comparison of the Risks, Benefits and Cost Effectiveness of Primary Carotid Stenting With Carotid Endarterectomy: International Carotid Stenting Study; ISRCTN25337470

    Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    Get PDF
    To assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced low-radiation-dose chest CT for lung cancer screening were included. Non-imaging predictors (age, smoking status and pack-years) were collected and imaging-predictors (calcium volume of the coronary arteries, aorta, aortic valve and mitral valve/annulus) were obtained. The outcome was the occurrence of cardiovascular events. Multivariable Cox proportional-hazards regression was used to calculate hazard-ratios (HRs) with 95 % confidence interval (CI). Subsequently, concordance-statistics were calculated. In total 3111 individuals were included, of whom 186 (6.0 %) developed a cardiovascular event during a follow-up of 2.9 (Q1–Q3, 2.7–3.3) years. If aortic (n = 657) or mitral (n = 85) annulus/valve calcifications were present, cardiovascular event incidence increased to 9.0 % (n = 59) or 12.9 % (n = 11), respectively. HRs of aortic and mitral valve/annulus calcium volume for cardiovascular events were 1.46 (95 % CI, 1.09–1.84) and 2.74 (95 % CI, 0.92–4.56) per 500 mm3. The c-statistic of a basic model including age, pack-years, current smoking status, coronary and aorta calcium volume was 0.68 (95 % CI, 0.63–0.72), which did not change after adding heart valve calcium volume. Aortic valve calcifications are predictors of future cardiovascular events. However, there was no added prognostic value beyond age, number of pack-years, current smoking status, coronary and aorta calcium volume for short term cardiovascular events

    Prediction of outcome in patients with suspected acute ischaemic stroke with CT perfusion and CT angiography: The Dutch acute stroke trial (DUST) study protocol

    Get PDF
    Background: Prediction of clinical outcome in the acute stage of ischaemic stroke can be difficult when based on patient characteristics, clinical findings and on non-contrast CT. CT perfusion and CT angiography may provide additional prognostic information and guide treatment in the early stage. We present the study protocol of the Dutch acute Stroke Trial (DUST). The DUST aims to assess the prognostic value of CT perfusion and CT angiography in predicting stroke outcome, in addition to patient characteristics and non-contrast CT. For this purpose, individualised prediction models for clinical outcome after stroke based on the best predictors from patient characteristics and CT imaging will be developed and validated.Methods/design: The DUST is a prospective multi-centre cohort study in 1500 patients with suspected acute ischaemic stroke. All patients undergo non-contrast CT, CT perfusion and CT angiography within 9 hours after onset of the neurological deficits, and, if possible, follow-up imaging after 3 days. The primary outcome is a dichotomised score on the modified Rankin Scale, assessed at 90 days. A score of 0-2 represents good outcome, and a score of 3-6 represents poor outcome. Three logistic regression models will be developed, including patient characteristics and non-contrast CT (model A), with addition of CT angiography (model B), and CT perfusion parameters (model C). Model derivation will be performed in 60% of the study population, and model validation in the remaining 40% of the patients. Additional prognostic value of the models will be determined with the area under the curve (AUC) from the receiver operating characteristic (ROC) curve, calibration plots, assessment of goodness-of-fit, and likelihood ratio tests.Discussion: This study will provide insight in the added prognosti

    No additional prognostic value of genetic information in the prediction of vascular events after cerebral ischemia of arterial origin

    Get PDF
    Background: Patients who have suffered from cerebral ischemia have a high risk of recurrent vascular events. Predictive models based on classical risk factors typically have limited prognostic value. Given that cerebral ischemia has a heritable component, genetic information might improve performance of these risk models. Our aim was to develop and compare two models: one containing traditional vascular risk factors, the other also including genetic information. Methods and Results: We studied 1020 patients with cerebral ischemia and genotyped them with the Illumina Immunochip. Median follow-up time was 6.5 years; the annual incidence of new ischemic events (primary outcome, n=198) was 3.0%. The prognostic model based on classical vascular risk factors had an area under the receiver operating characteristics curve (AUC-ROC) of 0.65 (95% confidence interval 0.61-0.69). When we added a genetic risk score based on prioritized SNPs from a genome-wide association study of ischemic stroke (using summary statistics from the METASTROKE study which included 12389 cases and 62004 controls), the AUC-ROC remained the same. Similar results were found for the secondary outcome ischemic stroke. Conclusions: We found no additional value of genetic information in a prognostic model for the risk of ischemic events in patients with cerebral ischemia of arterial origin. This is consistent with a complex, polygenic architecture, where many genes of weak effect likely act in concert to influence the heritable risk of an individual to develop (recurrent) vascular events. At present, genetic information cannot help clinicians to distinguish patients at high risk for recurrent vascular events

    No relation between body temperature and arterial recanalization at three days in patients with acute ischaemic stroke

    Get PDF
    Background: Recanalization of an occluded intracranial artery is influenced by temperature-dependent enzymes, including alteplase. We assessed the relation between body temperature on admission and recanalization. Methods: We included 278 patients with acute ischaemic stroke within nine hours after symptom onset, who had an intracranial arterial occlusion on admission CT angiography, in 13 participating centres. We calculated the relation per every 0.1°Celsius increase in admission body temperature and recanalization at three days. Results: Recanalization occurred in 80% of occluded arteries. There was no relation between body temperature and recanalization at three days after adjustments for age, NIHSS score on admission and treatment with alteplase (adjusted odds ratio per 0.1°Celsius, 0.99; 95% confidence interval, 0.94-1.05; p = 0.70). Results for patients treated or not treated with alteplase were essentially the same. Conclusions: Our findings suggest that in patients with acute ischaemic stroke there is no relation between body temperature on admission and recanalization of an occluded intracranial artery three days later, irrespective of treatment with alteplase
    corecore