41 research outputs found

    Existence Theory for the Radically Symmetric Contact Lens Equation

    Get PDF
    In this paper we present a variational formulation of the problem of determining the elastic stresses in a contact lens on an eye and the induced suction pressure distribution in the tear film between the eye and the lens. This complements the force-balance derivation that we used in earlier work [K. L. Maki and D. S. Ross, J. Bio. Sys., 22 (2014), pp. 235–248]. We investigate the existence of solutions of the relevant boundary value problem for the singular, second-order Euler–Lagrange equation. We prove that, for lenses of constant thickness, solutions exist. We present an example to show that in some cases in which the lens thickness increases with distance from the lens center no solution exists

    Maximizing Minimum Pressure in Fluid Dynamic Bearings of Hard Disk Drives

    Get PDF
    We focus on the central spindle which supports the rotating magnetic platters which hold all of the data. The spindle must operate with great precision and stability at high rotational speeds. Design practice has converged on oil-lubricated hydrodynamic journal bearings as the most common choice for spindles. That is, a layer of viscous oil separates a rotating shaft (the bearing) from the fixed outer sleeve (the journal). In hard drives, it is very important for the shaft to be centered within the sleeve. Plain journal bearings (i.e. both surfaces are circular cylinders) are unstable to perturbations that push the shaft off-center. It was found that this stability problem can be overcome by cutting diagonal grooves into the journal in a pattern called a herring-bone. Another consequence of this design is that very high pressures are generated by the grooves as they drive the oil to the middle of the bearing, away from the top/bottom ends of the spindle. This pumping action generally works to oppose leakage out of the bearing. We examine how choices for the groove pattern can influence the key properties of the bearing. The focus is to understand the effect of the groove geometry on the pumping action. In particular the undesirable behavior caused by the low pressures created near the top/bottom ends of the bearing which, under many conditions, may result in the pressure becoming negative, relative to atmospheric pressure. Negative pressure can result in cavitation or, when it occurs near an air-oil interface, can cause air to be ingested and hence create bubbles. Any bubbles in the oil can corrupt the lubricating layer in the bearing and, as they are created and collapse, can cause significant undesirable vibrations. The negative pressures have therefore been identified as one of the key problems in design of hard disk drive bearings. We will use numerical computations and some analysis to show that by modifying the groove geometry we can reduce the negative pressure while retaining good stability characteristics

    Emerging roles of ATF2 and the dynamic AP1 network in cancer

    Get PDF
    Cooperation among transcription factors is central for their ability to execute specific transcriptional programmes. The AP1 complex exemplifies a network of transcription factors that function in unison under normal circumstances and during the course of tumour development and progression. This Perspective summarizes our current understanding of the changes in members of the AP1 complex and the role of ATF2 as part of this complex in tumorigenesis.Fil: Lopez Bergami, Pablo Roberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Biología y Medicina Experimental (i); Argentina; ArgentinaFil: Lau, Eric . Burnham Institute for Medical Research; Estados UnidosFil: Ronai, Zeev . Burnham Institute for Medical Research; Estados Unido

    Hitomi (ASTRO-H) X-ray Astronomy Satellite

    Get PDF
    The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E  >  2  keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month

    Post-intervention Status in Patients With Refractory Myasthenia Gravis Treated With Eculizumab During REGAIN and Its Open-Label Extension

    Get PDF
    OBJECTIVE: To evaluate whether eculizumab helps patients with anti-acetylcholine receptor-positive (AChR+) refractory generalized myasthenia gravis (gMG) achieve the Myasthenia Gravis Foundation of America (MGFA) post-intervention status of minimal manifestations (MM), we assessed patients' status throughout REGAIN (Safety and Efficacy of Eculizumab in AChR+ Refractory Generalized Myasthenia Gravis) and its open-label extension. METHODS: Patients who completed the REGAIN randomized controlled trial and continued into the open-label extension were included in this tertiary endpoint analysis. Patients were assessed for the MGFA post-intervention status of improved, unchanged, worse, MM, and pharmacologic remission at defined time points during REGAIN and through week 130 of the open-label study. RESULTS: A total of 117 patients completed REGAIN and continued into the open-label study (eculizumab/eculizumab: 56; placebo/eculizumab: 61). At week 26 of REGAIN, more eculizumab-treated patients than placebo-treated patients achieved a status of improved (60.7% vs 41.7%) or MM (25.0% vs 13.3%; common OR: 2.3; 95% CI: 1.1-4.5). After 130 weeks of eculizumab treatment, 88.0% of patients achieved improved status and 57.3% of patients achieved MM status. The safety profile of eculizumab was consistent with its known profile and no new safety signals were detected. CONCLUSION: Eculizumab led to rapid and sustained achievement of MM in patients with AChR+ refractory gMG. These findings support the use of eculizumab in this previously difficult-to-treat patient population. CLINICALTRIALSGOV IDENTIFIER: REGAIN, NCT01997229; REGAIN open-label extension, NCT02301624. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that, after 26 weeks of eculizumab treatment, 25.0% of adults with AChR+ refractory gMG achieved MM, compared with 13.3% who received placebo

    Minimal Symptom Expression' in Patients With Acetylcholine Receptor Antibody-Positive Refractory Generalized Myasthenia Gravis Treated With Eculizumab

    Get PDF
    The efficacy and tolerability of eculizumab were assessed in REGAIN, a 26-week, phase 3, randomized, double-blind, placebo-controlled study in anti-acetylcholine receptor antibody-positive (AChR+) refractory generalized myasthenia gravis (gMG), and its open-label extension

    OBSERVATION OF CONTACT LINE DYNAMICS IN EVAPORATING DROPLETS UNDER THE INFLUENCE OF ELECTRIC FIELDS

    No full text
    ABSTRACT Deposition of colloidal material in evaporating droplets is important in many applications including DNA sequencing and medical diagnostic testing. When colloidal droplets evaporate, the majority of material is often deposited at the periphery of the resultant deposition in a coffee-ring pattern. Formation of this pattern is the result of contact line pinning and the interplay between evaporative and surface tension effects in the droplet. When the contact line is pinned and the evaporative flux in the droplet is highest at the periphery, a radially outward flow is generated to conserve mass that deposits particles in the fluid at the contact line. Evaporation at the contact line can also create a temperature gradient across the droplet. This gradient gives rise to a surface tension driven flow that can resuspend particles in the droplet. When the evaporative flow dominates, particles are deposited at the contact line in a coffee-ring pattern. The presence of the coffee-ring pattern is undesirable in many printing and medical diagnostic processes. Suppression of the coffee-ring effect has been achieved by addition of surfactant, enhancement of surface tension flow, surface modification, alteration of particle shape, and application of an electric field. Manipulation of the coffee-ring effect has been achieved through the application of both AC and DC electric fields
    corecore