403 research outputs found

    A numerical analysis of an Active Magnetic Regenerative Refrigerant system with a multi-layer regenerator

    No full text
    Abstract The Active Magnetic Regenerative Refrigeration (AMRR) cycle is a special kind of regenerator for the magnetic refrigerator, in which the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. The performance of an AMRR cycle depends strongly on the behaviour of the adiabatic magnetization temperature change as a function of material temperature in the flow direction of the regenerator. In the present paper, a practical model for predicting the performance and efficiency of an AMRR cycle has been developed. The model simulates both the ferromagnetic material and the entire cycle of an AMR operating in conformity with a Brayton regenerative cycle. The model simulates different kinds of layered regenerators operating at their optimal operation point. The program study the Gd-x Tb1-x alloys as constituent materials for the regenerator over the temperature range 275 – 295 K, and Gdx Dy1-x alloys in the temperature range 260 – 280 K. With this model, the refrigeration capacity, the power consumption and consequently the coefficient of performance can be predicted. The results show a greater COP for the refrigerator based on the magnetocaloric technology compared with the COP of a classical vapour compression plant working between the same thermal levels

    Temporal overdrive recurrent neural network

    Get PDF
    In this work we present a novel recurrent neural network architecture designed to model systems characterized by multiple characteristic timescales in their dynamics. The proposed network is composed by several recurrent groups of neurons that are trained to separately adapt to each timescale, in order to improve the system identification process. We test our framework on time series prediction tasks and we show some promising, preliminary results achieved on synthetic data. To evaluate the capabilities of our network, we compare the performance with several state-of-the-art recurrent architectures

    General rules for bosonic bunching in multimode interferometers

    Full text link
    We perform a comprehensive set of experiments that characterize bosonic bunching of up to 3 photons in interferometers of up to 16 modes. Our experiments verify two rules that govern bosonic bunching. The first rule, obtained recently in [1,2], predicts the average behavior of the bunching probability and is known as the bosonic birthday paradox. The second rule is new, and establishes a n!-factor quantum enhancement for the probability that all n bosons bunch in a single output mode, with respect to the case of distinguishable bosons. Besides its fundamental importance in phenomena such as Bose-Einstein condensation, bosonic bunching can be exploited in applications such as linear optical quantum computing and quantum-enhanced metrology.Comment: 6 pages, 4 figures, and supplementary material (4 pages, 1 figure

    Individual metering and submetering for cooling application

    Get PDF
    In 2012 the Energy Efficiency Directive (EED) has set mandatory installation of individual metering and submetering systems for accounting thermal energy consumption in buildings where centralized heating/cooling sources are present, when technically feasible and cost efficient. As a consequence, direct thermal energy meters or indirect heat accounting systems have spread widely in residential buildings, for metering and sub-metering in space heating applications. On the other hand, individual metering of thermal energy in space cooling is a difficult task, due to the very different types of cooling systems and to the lack of technical and legal metrology regulation. In this paper possible solutions available for direct metering and submetering of different types of centralized cooling systems are discussed. Indeed, for direct metering application, the cooling fluid flow metering is a particularly crucial issue due to small pipe diameters and different fluid properties. Thus, the authors carried out an experimental comparison between a Coriolis flow-meter and an ultrasonic clamp-on flow-meter in the cooling fluid circuit of a direct expansion system. Tests have been performed at different operative temperature differences between flow and return, showing relative errors within ± 10%

    Pequeños vertebrados del relleno kárstico del Pleistoceno Superior de Avetrana (Apulia, Sur de Italia)

    Get PDF
    The fossiliferous deposit (karst cavity) in La Grave, a locality near the small town of Avetrana (Taranto, south­ern Italy), has yielded numerous fossils of vertebrates. The remains of large mammals have been the subject of several studies. This paper examines the remains of small vertebrates and identifies four taxa of amphibians (Bufo bufo, Bufotes gr. B. viridis, Hyla gr. H. Arborea and Rana (s.l.) sp.), four taxa of reptiles (Testudo hermanni, Podarcis sp., Zamenis gr. Z. longissimus, Natrix natrix), and nine taxa of small mammals (Erinaceus europaeus, Crocidura suaveolens, Arvicola italicus, Microtus (Terricola) savii, Microtus (Microtus) arvalis, Apodemus gr. A. sylvaticus - A. flavicollis, Hystrix (Acanthion) vinogradovi, Oryctolagus cuniculus and Lepus corsicanus). From a biochronological point of view, the data on small and large vertebrates indicate an age between the beginning of the Late Pleistocene (MIS 5e) and the central part of MIS 3. The most recent fossiliferous layer (bed 8) is likely to have been deposited during a cooler period when compared to the previous layers.The data from small fossil vertebrates combined with those emerging from the large mammals and birds evidence the presence, near the karstic cavity, of open spaces (prairies) with pools of water, bordered by wooded areas and, not far, the presence of a rocky coastline.El depósito (cavidad kárstica) de La Grave, localidad cercana a la pequeña ciudad de Avetrana (Tarento, Italia meridional), ha dado lugar a numerosos fósiles de vertebrados. Los restos de grandes mamíferos han sido objeto de varios estudios. En este trabajo se examinan los restos de pequeños vertebrados y se identifican cuatro taxones de anfibios (Bufo bufo, Bufotes gr. B. viridis, Hyla gr. H. Arborea and Rana (s.l.) sp.), cuatro de reptiles (Testudo hermanni, Podarcis sp., Zamenis gr. Z. longissimus, Natrix natrix), y nueve de pequeños mamíferos (Erinaceus europaeus, Crocidura suaveolens, Arvicola italicus, Microtus (Terricola) savii, Microtus (Microtus) arva­lis, Apodemus gr. A. sylvaticus - A. flavicollis, Hystrix (Acanthion) vinogradovi, Oryctolagus cuniculus and Lepus corsicanus). Desde un punto de vista biocronológico, los datos sobre los vertebrados pequeños y grandes indican una edad entre el comienzo del Pleistoceno tardío (MIS 5e) y la parte central del MIS 3. Es probable que el estrato fosilífero más reciente (nivel 8) se haya depositado durante un período más frío en comparación con las capas anteriores. Los datos de pequeños vertebrados fósiles combinados con los que proceden de los grandes mamífe­ros y aves evidencian la presencia, cerca de la cavidad kárstica, de espacios abiertos (praderas) con charcos de agua, bordeados por zonas boscosas y, no muy lejos, la presencia de una costa rocosa

    Expanded Total Equivalent Warming Impact analysis on experimental standalone fresh-food refrigerator

    Get PDF
    The stand-alone refrigerators for fresh food storage represent a large part of supermarket refrigeration equip-ment. In these devices, the usage of refrigerants with low Global Warming Potential allows the mitigation of the direct emissions due to refrigerant leakages. In contrast, the indirect emissions in these components are highly dependent on the refrigerant charge, leakage, and equivalent emission factors related to the electricity pro-duction mix. The most used index to evaluate the environmental impact of refrigerators is the Total Equivalent Warming Impact. Despite that this index presents limits on the fixed evaluation of many parameters such as refrigerant charge, electricity consumption and, electricity emission factor. Otherwise in this study, an accurate evaluation of refrigerators emissions has been realised by using the innovative Expanded Total Equivalent Warming Impact method to an experimental stand-alone refrigerator by using a dynamic approach to evaluate direct and indirect contributions. The environmental analysis considers four different refrigerants and four different countries of location. The results show that the indirect emissions due to electricity consumption cover the highest share of emissions. In addition, the operating years affected by low refrigerant charges are respon-sible for emissions by greater than 25% compared to other ones. The hourly equivalent emissions due to elec-tricity consumption in countries characterized by an electricity generation mix mainly based on renewable and/ or nuclear plants show an indirect environmental impact up to 5 times lower than countries with a natural gas -based electricity production mix. The study also defines new strategies to reduce the environmental impact of the stand-alone refrigerator such as the use of photovoltaic systems combined with this technology or earlier maintenance processes that could determine an equivalent emission saving of up to 38%

    A Comprehensive Energy Model for an Optimal Design of a Hybrid Refrigerated Van

    Get PDF
    The path towards decarbonization requires a progressive adaptation of all refrigeration systems, but only stationary ones have been intensely studied to improve their environmental performance. However, refrigerated transport is vital in the cold chain and must be considered in the green transition. In this paper, we propose a model for a hybrid refrigerated van that includes photovoltaic panels and electric batteries to decrease total greenhouse gas emissions from the engine. Thermal, electrical, and battery sub-models are considered and integrated into the comprehensive hybrid solar-powered refrigerated van model. Different technologies are compared, including lithium and lead-acid batteries and three different types of photovoltaic panels. The model was validated regarding van fuel consumption, showing a 4% deviation. Single and multiple delivery scenarios are considered to assess the energy, economic, and environmental benefits. Monthly CO2,e emissions could be reduced by 20% compared to a standard refrigerated van. Despite the environmental benefits provided by this sustainable solution, the payback period is still too long (above 20 years) because of the necessary investment to adapt the vehicle and considering fuel and electricity prices currently
    • …
    corecore