13 research outputs found

    Ventilación jet para la extracción de un cuerpo extraño endobronquial en un paciente con neumotórax drenado: Informe de caso

    Full text link
    Introduction Even though foreign body aspiration (FBA) is rare in adult patients, they sometimes require the performance of rigid bronchoscopy for its extraction. Ventilation for this procedure is challenging, especially in patients with pulmonary disease. Clinical, diagnostic evaluation and interventions We described the case of a 71-year old man who presented with a FBA in the left upper lobe associated with a controlateral pneumothorax. After the placement of a pleural drainage, the foreign body was extracted, using rigid bronchoscopy under general anaesthesia and high flow jet ventilation with no further haemodynamic or pulmonary complications, suggesting that this technique is safe in patients with pulmonary leaks. Conclusions In the case described, rigid bronchoscopy minimized the risk of aspiration of blood and detritus due to continuous flow of gas upward, and avoided the increase of the air leak through the pneumothorax thank to limited airway pressures, making it a clear indication.Introducción: Aunque la aspiración de cuerpos extraños es rara en adultos, requiere en algunas ocasiones la realización de una broncoscopia rígida para su extracción. El modo ventilatorio para este procedimiento es un reto, especialmente en pacientes con enfermedad pulmonar. Clínica, evaluación diagnóstica e intervenciones: Describimos aquí el caso de un paciente de 71 años con aspiración de un cuerpo extraño enclavado a nivel del lóbulo superior izquierdo asociado a un neumotórax contralateral. Después de insertar un tubo de tórax se extrajo el cuerpo extraño utilizando broncoscopia rígida bajo anestesia general y ventilación jet de alto flujo sin complicaciones hemodinámicas o pulmonares adicionales, sugiriendo que esta técnica es segura en pacientes con fugas pulmonares. Conclusiones: En el presente caso clínico, la broncoscopia rígida minimizó el riesgo de aspiración de sangre y detritus gracias a la inyección de un flujo continuo de gas ascendente, y evitó así el incremento de la fuga a través del neumotórax por las presiones limitadas en la vía aérea, constituyendo una indicación clara de esta técnic

    Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring for surgical hip repair in two patients with severe aortic stenosis

    Get PDF
    BACKGROUND AND OBJECTIVES: Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm2 or a mean aortic valve gradient >30 mm Hg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. CASE REPORT: Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2 mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. CONCLUSION: Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients

    Levosimendan as a treatment for acute renal failure associated with cardiogenic shock after hip fracture

    Get PDF
    Abstract Inotropic drugs are part of the treatment of heart failure; however, inotropic treatment has been largely debated due to the increased incidence of adverse effects and increased mortality. Recently levosimendan, an inotropic positive agent, has been proved to be effective in acute heart failure, reducing the mortality and improving cardiac and renal performance. We report the case of a 75-year-old woman with history of heart and renal failure and hip fracture. Levosimendan was used in preoperative preparation as an adjuvant therapy, to improve cardiac and renal function and to allow surgery

    Levosimendan as a treatment for acute renal failure associated with cardiogenic shock after hip fracture

    No full text
    Abstract Inotropic drugs are part of the treatment of heart failure; however, inotropic treatment has been largely debated due to the increased incidence of adverse effects and increased mortality. Recently levosimendan, an inotropic positive agent, has been proved to be effective in acute heart failure, reducing the mortality and improving cardiac and renal performance. We report the case of a 75-year-old woman with history of heart and renal failure and hip fracture. Levosimendan was used in preoperative preparation as an adjuvant therapy, to improve cardiac and renal function and to allow surgery

    Pulse contour analysis calibrated by Trans-pulmonar thermodilution (Picco Plus ® ) for the perioperative management of a caesarean section in a patient with severe cardiomyopathy

    Get PDF
    ABSTRACT BACKGROUND: The delivery of cardiac patients is a challenge for the anaesthesiologist, to whom the welfare of both the mother and the foetus is a main issue. In case of caesarean section, advanced monitoring allows to optimize haemodynamic condition and to improve morbidity and mortality. OBJECTIVE: To describe the use of pulse contour analysis calibrated by Trans-pulmonar thermodilution (Picco Plus® for the perioperative management of a caesarean section in a patient with severe cardiomyopathy. CASE REPORT: We describe the case of a 28-year-old woman with a congenital heart disease who was submitted to a caesarean section under general anaesthesia for maternal pathology and foetal breech presentation. Intra- and post-operative management was optimized by advanced haemodynamic monitorization obtained by pulse contour wave analysis and thermodilution calibration (Picco Plus® monitor). The information about preload, myocardial contractility and postcharge was useful in guiding the fluid therapy and the use of vasoactive drugs. CONCLUSION: This case report illustrates the importance of advanced haemodynamic monitoring with an acceptably invasive device in obstetric patients with high cardiac risk. The increasing experience in advanced haemodynamic management will probably permit to decrease morbidity and mortality of obstetric patients in the future

    Análise do contorno do pulso calibrado por termodiluição transpulmonar (Picco Plus®) para o manejo perioperatório de cesariana em paciente com miocardiopatia grave

    Get PDF
    ResumoJustificativaO parto em pacientes cardíacas é um desafio para o anestesiologista, para o qual o bem‐estar tanto da mãe quanto do feto é a questão principal. Em caso de cesariana, o monitoramento avançado permite melhorar a condição hemodinâmica e diminuir a morbidade e mortalidade.ObjetivoDescrever o uso da análise do contorno do pulso calibrado por termodiluição transpulmonar (Picco Plus®) para o manejo perioperatório de cesariana em paciente com miocardiopatia grave.Relato de casoDescrevemos o caso de uma paciente de 28 anos com uma doença cardíaca congênita, submetida a uma cesariana sob anestesia geral devido a afecção materna e apresentação fetal pélvica. O manejo nos períodos intraoperatório e pós‐operatório foi aprimorado por monitoração hemodinâmica avançada obtida pela análise do contorno da onda de pulso e calibração por termodiluição (monitor Picco Plus®). As informações sobre pré‐carga, pós‐carga e contratilidade miocárdica foram úteis para orientar a reposição hídrica e o uso de medicamentos vasoativos.ConclusãoEste relato de caso ilustra a importância da monitoração hemodinâmica avançada com dispositivo aceitavelmente invasivo em pacientes obstétricas com alto risco cardíaco. O aumento do conhecimento no manejo hemodinâmico avançado provavelmente possibilitará a redução da morbidade e mortalidade de pacientes obstétricas no futuro.AbstractBackgroundThe delivery of cardiac patients is a challenge for the anaesthesiologist, to whom the welfare of both the mother and the foetus is a main issue. In case of caesarean section, advanced monitoring allows to optimize haemodynamic condition and to improve morbidity and mortality.ObjectiveTo describe the use of pulse contour analysis calibrated by Trans‐pulmonar thermodilution (Picco Plus®) for the perioperative management of a caesarean section in a patient with severe cardiomyopathy.Case reportWe describe the case of a 28‐year‐old woman with a congenital heart disease who was submitted to a caesarean section under general anaesthesia for maternal pathology and foetal breech presentation. Intra‐ and post‐operative management was optimized by advanced haemodynamic monitorization obtained by pulse contour wave analysis and thermodilution calibration (Picco Plus® monitor). The information about preload, myocardial contractility and postcharge was useful in guiding the fluid therapy and the use of vasoactive drugs.ConclusionThis case report illustrates the importance of advanced haemodynamic monitoring with an acceptably invasive device in obstetric patients with high cardiac risk. The increasing experience in advanced haemodynamic management will probably permit to decrease morbidity and mortality of obstetric patients in the future

    Intraoperative transfusion practices in Europe

    Get PDF
    Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (pRBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month period in 2013. The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone initiated only 8.5% of transfusions. The Hb concentration [mean (sd)] just before transfusion was 8.1 (1.7) g dl and increased to 9.8 (1.8) g dl after transfusion. The mean number of intraoperatively transfused pRBC units was 2.5 (2.7) units (median 2). Although European Society of Anaesthesiology transfusion guidelines are moderately implemented in Europe with respect to Hb threshold for transfusion (7-9 g dl), there is still an urgent need for further educational efforts that focus on the number of pRBC units to be transfused at this threshold
    corecore