415 research outputs found

    Comparative analysis of selected exhaled breath biomarkers obtained with two different temperature-controlled devices

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The collection of exhaled breath condensate (EBC) is a suitable and non-invasive method for evaluation of airway inflammation. Several studies indicate that the composition of the condensate and the recovery of biomarkers are affected by physical characteristics of the condensing device and collecting circumstances. Additionally, there is an apparent influence of the condensing temperature, and often the level of detection of the assay is a limiting factor. The ECoScreen2 device is a new, partly single-use disposable system designed for studying different lung compartments.</p> <p>Methods</p> <p>EBC samples were collected from 16 healthy non-smokers by using the two commercially available devices ECoScreen2 and ECoScreen at a controlled temperature of -20°C. EBC volume, pH, NOx, LTB<sub>4</sub>, PGE<sub>2</sub>, 8-isoprostane and cys-LTs were determined.</p> <p>Results</p> <p>EBC collected with ECoScreen2 was less acidic compared to ECoScreen. ECoScreen2 was superior concerning condensate volume and detection of biomarkers, as more samples were above the detection limit (LTB<sub>4 </sub>and PGE<sub>2</sub>) or showed higher concentrations (8-isoprostane). However, NOx was detected only in EBC sampled by ECoScreen.</p> <p>Conclusion</p> <p>ECoScreen2 in combination with mediator specific enzyme immunoassays may be suitable for measurement of different biomarkers. Using this equipment, patterns of markers can be assessed that are likely to reflect the complex pathophysiological processes in inflammatory respiratory disease.</p

    Sputum and nasal lavage lung-specific biomarkers before and after smoking cessation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Little is known about the effect of smoking cessation on airway inflammation. Secretory Leukocyte Protease Inhibitor (SLPI), Clara Cell protein 16 (CC16), elafin and human defensin beta-2 (HBD-2) protect human airways against inflammation and oxidative stress. In this longitudinal study we aimed to investigate changes in sputum and nasal lavage SLPI, CC16, elafin and HBD-2 levels in healthy smokers after 6 and 12 months of smoking cessation.</p> <p>Methods</p> <p>Induced sputum and nasal lavage was obtained from healthy current smokers (n = 76) before smoking cessation, after 6 months of smoking cessation (n = 29), after 1 year of smoking cessation (n = 22) and from 10 healthy never smokers. SLPI, CC16, elafin and HBD-2 levels were measured in sputum and nasal lavage supernatants by commercially available ELISA kits.</p> <p>Results</p> <p>Sputum SLPI and CC-16 levels were increased in healthy smokers before smoking cessation versus never-smokers (p = 0.005 and p = 0.08 respectively). SLPI and CC16 levels did not differ before and 6 months after smoking cessation (p = 0.118 and p = 0.543 respectively), neither before and 1 year after smoking cessation (p = 0.363 and p = 0.470 respectively). Nasal lavage SLPI was decreased 12 months after smoking cessation (p = 0.033). Nasal lavage elafin levels were increased in healthy smokers before smoking cessation versus never-smokers (p = 0.007), but there were no changes 6 months and 1 year after smoking cessation.</p> <p>Conclusions</p> <p>Only nasal lavage SLPI decrease after 1 year after smoking cessation. We may speculate that there is an ongoing inflammatory process stimulating the production of counter-regulating proteins in the airways of healthy ex-smokers.</p

    An easily integrable industrial system for gamma spectroscopic analysis and traceability of stones and building materials

    Get PDF
    In the building material and stones market, lots of restrictions are coming in different world zones. In Europe, a recent regulatory set up the maximum level of radiological emissions for materials intended for use in public and private building structures. For this reason, companies need to have a very efficient radiological measurements system in their production chain, in order to respect all the rules and to be competitive in the world market. This article describes CORSAIR, a Cloud-Oriented Measurement System for Radiological Investigation and Traceability of Stones. Our cyber-physical system consists of sensing nodes network connected to a data collection gateway through LoRaWAN protocol, and interfaces with a centralized cloud application. CORSAIR introduces a fast, repeatable, real-time and non-destructive method to measure radiological emissions and other parameters of each single building material item, uniquely identified by an applied RFID tag. The validity of this system is confirmed by in-situ measurement campaign compared with high-precision laboratory analysis. The results demonstrate the accuracy of the CORSAIR sensor and the possibility to easily integrate it in the company production chain without any change

    Discrimination between oral corticosteroid-treated and oral corticosteroid-non-treated severe asthma patients by an electronic nose platform

    Get PDF
    Rationale: Some severe asthma patients require oral corticosteroids (OCS) likely due to greater disease severity. Exhaled molecular markers can provide phenotypic information in asthma. Objectives: Determine whether patients on OCS (OCS+) have a different breathprint compared with those who were not on OCS (OCS-); determine the classification accuracy of eNose as compared to FEV1 % pred, % sputum eosinophils, and exhaled nitric oxide (FENO). Methods: This was a cross-sectional analysis of the U-BIOPRED cohort. Severe asthma was defined by IMI-criteria [Bel Thorax 2011]. OCS+ patients had daily OCS. OCS- patients had never had OCS and were on maintenance inhaled fluticasone equivalent >1000 μg/day. Exhaled volatile organic compounds trapped on adsorption tubes were analysed by centralized eNose platform (Owlstone Lonestar, Cyranose 320, Comon Invent, Tor Vergata TEN) including a total of 190 sensors. t test was used for comparing groups and support vector machine with leave-one-out cross-validation as a classifier. Results: 33 OCS+ (age 55±11yr, mean±SD, 52% female, 27% smokers, pre-bronchodilator FEV1 64.1±24% pred) and 40 OCS- severe asthma patients (age 54±15yr, mean±SD, 55% female, 35% smokers, pre-bronchodilator FEV1 61.8±24% pred) were studied. Sensor by sensor analysis showed that 56 sensors provided different mean values (change in sensor resistance or frequency) between groups (P<0.05). Accuracy of classification was as follows: eNose 71% (n=73), FENO 71% (n=70), FEV1 62% (n=73) and sputum eosinophils 59% (n=37). Conclusions: Preliminary results suggest OCS+ and OCS- severe asthma patients can be distinguished by an eNose platform

    Breathomics can discriminate between anti IgE-treated and non-treated severe asthma adults

    Get PDF
    Rationale: Omalizumab, an anti-IgE monoclonal antibody, is indicated in adults with severe persistent allergic asthma. Exhaled molecular markers can provide phenotypic information in asthma. Objectives: Determine whether adults with severe asthma on omalizumab (anti-IgE+) have a different breathprint compared with those who were not on anti-IgE therapy (anti-IgE-) as assessed by eNoses and gas chromatography/mass spectrometry (GC/MS) (breathomics). Methods: This was a cross-sectional analysis of the U- BIOPRED adult cohort. Severe asthma was defined by IMI-criteria [Bel, Thorax 2011]. Anti-IgE+ patients were on a regular treatment with s.c. omalizumab (150-375 mg) every 2-4 weeks. Exhaled volatile compounds trapped on adsorption tubes were analysed by a centralized eNose platform (Owlstone Lonestar, two Cyranose 320, Comon Invent, Tor Vergata TEN), including a total of 190 sensors, and GC/MS. Recursive feature elimination (http://topepo.github.io/caret/rfe.html) was used for feature selection and random forests, more robust to overfitting, for classification. Results: 9 anti- IgE+ (females/males 2/7, age 52.6±16.3 years, mean±SD, 1/2/6 current/ex/nonsmokers, pre-bronchodilator FEV1 70.6±21.1% predicted value) and 30 anti-IgE- patients (18/12 females/males, age 53.2±14.2 years, 0/16/14 current/ex/nonsmokers, pre-bronchodilator FEV1 59.6±30.7% predicted value) were studied. Conclusions: Preliminary results suggest that breathomics can distinguish between anti-IgE+ and anti-IgE- severe asthma patients

    The Main Results of the Borexino Experiment

    Full text link
    The main physical results on the registration of solar neutrinos and the search for rare processes obtained by the Borexino collaboration to date are presented.Comment: 8 pages, 8 figgures, To be published as Proceedings of the Third Annual Large Hadron Collider Physics Conference, St. Petersburg, Russia, 201

    Haemophilus influenzae and Moraxella catarrhalis in sputum of severe asthma with inflammasome and neutrophil activation

    Get PDF
    BACKGROUND: Because of altered airway microbiome in asthma, we analysed the bacterial species in sputum of patients with severe asthma. METHODS: Whole genome sequencing was performed on induced sputum from non-smoking (SAn) and current or ex-smoker (SAs/ex) severe asthma patients, mild/moderate asthma (MMA) and healthy controls (HC). Data were analysed by asthma severity, inflammatory status and transcriptome-associated clusters (TACs). RESULTS: α-diversity at the species level was lower in SAn and SAs/ex, with an increase in Haemophilus influenzae and Moraxella catarrhalis, and Haemophilus influenzae and Tropheryma whipplei, respectively, compared to HC. In neutrophilic asthma, there was greater abundance of Haemophilus influenzae and Moraxella catarrhalis and in eosinophilic asthma, Tropheryma whipplei was increased. There was a reduction in α-diversity in TAC1 and TAC2 that expressed high levels of Haemophilus influenzae and Tropheryma whipplei, and Haemophilus influenzae and Moraxella catarrhalis, respectively, compared to HC. Sputum neutrophils correlated positively with Moraxella catarrhalis and negatively with Prevotella, Neisseria and Veillonella species and Haemophilus parainfluenzae. Sputum eosinophils correlated positively with Tropheryma whipplei which correlated with pack-years of smoking. α- and β-diversities were stable at one year. CONCLUSIONS: Haemophilus influenzae and Moraxella catarrhalis were more abundant in severe neutrophilic asthma and TAC2 linked to inflammasome and neutrophil activation, while Haemophilus influenzae and Tropheryma whipplei were highest in SAs/ex and in TAC1 associated with highest expression of IL-13 type 2 and ILC2 signatures with the abundance of Tropheryma whipplei correlating positively with sputum eosinophils. Whether these bacterial species drive the inflammatory response in asthma needs evaluation

    Final results of Borexino Phase-I on low energy solar neutrino spectroscopy

    Full text link
    Borexino has been running since May 2007 at the LNGS with the primary goal of detecting solar neutrinos. The detector, a large, unsegmented liquid scintillator calorimeter characterized by unprecedented low levels of intrinsic radioactivity, is optimized for the study of the lower energy part of the spectrum. During the Phase-I (2007-2010) Borexino first detected and then precisely measured the flux of the 7Be solar neutrinos, ruled out any significant day-night asymmetry of their interaction rate, made the first direct observation of the pep neutrinos, and set the tightest upper limit on the flux of CNO neutrinos. In this paper we discuss the signal signature and provide a comprehensive description of the backgrounds, quantify their event rates, describe the methods for their identification, selection or subtraction, and describe data analysis. Key features are an extensive in situ calibration program using radioactive sources, the detailed modeling of the detector response, the ability to define an innermost fiducial volume with extremely low background via software cuts, and the excellent pulse-shape discrimination capability of the scintillator that allows particle identification. We report a measurement of the annual modulation of the 7 Be neutrino interaction rate. The period, the amplitude, and the phase of the observed modulation are consistent with the solar origin of these events, and the absence of their annual modulation is rejected with higher than 99% C.L. The physics implications of phase-I results in the context of the neutrino oscillation physics and solar models are presented
    corecore