664 research outputs found

    Measuring diet in primary school children aged 8-11 years: validation of the Child and Diet Evaluation Tool (CADET) with an emphasis on fruit and vegetable intake.

    Get PDF
    Background/Objectives:The Child And Diet Evaluation Tool (CADET) is a 24-h food diary that measures the nutrition intake of children aged 3-7 years, with a focus on fruit and vegetable consumption. Until now CADET has not been used to measure nutrient intake of children aged 8-11 years. To ensure that newly assigned portion sizes for this older age group were valid, participants were asked to complete the CADET diary (the school and home food diary) concurrently with a 1-day weighed record. Subjects/Methods:A total of 67 children with a mean age of 9.3 years (s.d.: ± 1.4, 51% girls) participated in the study. Total fruit and vegetable intake in grams and other nutrients were extracted to compare the mean intakes from the CADET diary and Weighed record using t-tests and Pearson's r correlations. Bland-Altman analysis was also conducted to assess the agreement between the two methods. Results: Correlations comparing the CADET diary to the weighed record were high for fruit, vegetables and combined fruit and vegetables (r=0.7). The results from the Bland-Altman plots revealed a mean difference of 54 g (95% confidence interval: -88, 152) for combined fruit and vegetables intake. CADET is the only tool recommended by the National Obesity Observatory that has been validated in a UK population and provides nutrient level data on children's diets. Conclusions:The results from this study conclude that CADET can provide high-quality nutrient data suitable for evaluating intervention studies now for children aged 3-11 years with a focus on fruit and vegetable intake

    Exploring multilocus associations of inflammation genes and colorectal cancer risk using hapConstructor

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In candidate-gene association studies of single nucleotide polymorphisms (SNPs), multilocus analyses are frequently of high dimensionality when considering haplotypes or haplotype pairs (diplotypes) and differing modes of expression. Often, while candidate genes are selected based on their biological involvement in a given pathway, little is known about the functionality of SNPs to guide association studies. Investigators face the challenge of exploring multiple SNP models to elucidate which variants, independently or in combination, might be associated with a disease of interest. A data mining module, hapConstructor (freely-available in Genie software) performs systematic construction and association testing of multilocus genotype data in a Monte Carlo framework. Our objective was to assess its utility to guide statistical analyses of haplotypes within a candidate region (or combined genotypes across candidate genes) beyond that offered by a standard logistic regression approach.</p> <p>Methods</p> <p>We applied the hapConstructor method to a multilocus investigation of candidate genes involved in pro-inflammatory cytokine IL6 production, <it>IKBKB</it>, <it>IL6</it>, and <it>NFKB1 </it>(16 SNPs total) hypothesized to operate together to alter colorectal cancer risk. Data come from two U.S. multicenter studies, one of colon cancer (1,556 cases and 1,956 matched controls) and one of rectal cancer (754 cases and 959 matched controls).</p> <p>Results</p> <p>HapConstrcutor enabled us to identify important associations that were further analyzed in logistic regression models to simultaneously adjust for confounders. The most significant finding (nominal <it>P </it>= 0.0004; false discovery rate <it>q </it>= 0.037) was a combined genotype association across <it>IKBKB </it>SNP rs5029748 (1 or 2 variant alleles), <it>IL6 </it>rs1800797 (1 or 2 variant alleles), and <it>NFKB1 </it>rs4648110 (2 variant alleles) which conferred an ~80% decreased risk of colon cancer.</p> <p>Conclusions</p> <p>Strengths of hapConstructor were: systematic identification of multiple loci within and across genes important in CRC risk; false discovery rate assessment; and efficient guidance of subsequent logistic regression analyses.</p

    Wavelength-scale stationary-wave integrated Fourier-transform spectrometry

    Get PDF
    Spectrometry is a general physical-analysis approach for investigating light-matter interactions. However, the complex designs of existing spectrometers render them resistant to simplification and miniaturization, both of which are vital for applications in micro- and nanotechnology and which are now undergoing intensive research. Stationary-wave integrated Fourier-transform spectrometry (SWIFTS)-an approach based on direct intensity detection of a standing wave resulting from either reflection (as in the principle of colour photography by Gabriel Lippmann) or counterpropagative interference phenomenon-is expected to be able to overcome this drawback. Here, we present a SWIFTS-based spectrometer relying on an original optical near-field detection method in which optical nanoprobes are used to sample directly the evanescent standing wave in the waveguide. Combined with integrated optics, we report a way of reducing the volume of the spectrometer to a few hundreds of cubic wavelengths. This is the first attempt, using SWIFTS, to produce a very small integrated one-dimensional spectrometer suitable for applications where microspectrometers are essential

    Cell-free (RNA) and cell-associated (DNA) HIV-1 and postnatal transmission through breastfeeding

    Get PDF
    &lt;p&gt;Introduction - Transmission through breastfeeding remains important for mother-to-child transmission (MTCT) in resource-limited settings. We quantify the relationship between cell-free (RNA) and cell-associated (DNA) shedding of HIV-1 virus in breastmilk and the risk of postnatal HIV-1 transmission in the first 6 months postpartum.&lt;/p&gt; &lt;p&gt;Materials and Methods - Thirty-six HIV-positive mothers who transmitted HIV-1 by breastfeeding were matched to 36 non-transmitting HIV-1 infected mothers in a case-control study nested in a cohort of HIV-infected women. RNA and DNA were quantified in the same breastmilk sample taken at 6 weeks and 6 months. Cox regression analysis assessed the association between cell-free and cell-associated virus levels and risk of postnatal HIV-1 transmission.&lt;/p&gt; &lt;p&gt;Results - There were higher median levels of cell-free than cell-associated HIV-1 virus (per ml) in breastmilk at 6 weeks and 6 months. Multivariably, adjusting for antenatal CD4 count and maternal plasma viral load, at 6 weeks, each 10-fold increase in cell-free or cell-associated levels (per ml) was significantly associated with HIV-1 transmission but stronger for cell-associated than cell-free levels [2.47 (95% CI 1.33–4.59) vs. aHR 1.52 (95% CI, 1.17–1.96), respectively]. At 6 months, cell-free and cell-associated levels (per ml) in breastmilk remained significantly associated with HIV-1 transmission but was stronger for cell-free than cell-associated levels [aHR 2.53 (95% CI 1.64–3.92) vs. 1.73 (95% CI 0.94–3.19), respectively].&lt;/p&gt; &lt;p&gt;Conclusions - The findings suggest that cell-associated virus level (per ml) is more important for early postpartum HIV-1 transmission (at 6 weeks) than cell-free virus. As cell-associated virus levels have been consistently detected in breastmilk despite antiretroviral therapy, this highlights a potential challenge for resource-limited settings to achieve the UNAIDS goal for 2015 of eliminating vertical transmission. More studies would further knowledge on mechanisms of HIV-1 transmission and help develop more effective drugs during lactation.&lt;/p&gt

    A re-appraisal of the reliability of the 20 m multi-stage shuttle run test

    Get PDF
    This is the author's PDF version of an article published in European journal of applied physiology in 2007. The original publication is available at www.springerlink.co

    Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Piezoresistive pressure measurement technique (PRM) has previously been applied for direct IAP measurement in a porcine model using two different devices. Aim of this clinical study was to assess both devices regarding complications, reliability and agreement with IVP in patients undergoing elective abdominal surgery.</p> <p>Methods</p> <p>A prospective cohort study was performed in 20 patients randomly scheduled to receive PRM either by a Coach<sup>®</sup>-probe or an Accurate++<sup>®</sup>-probe (both MIPM, Mammendorf, Germany). Probes were placed on the greater omentum and passed through the abdominal wall paralleling routine drainages. PRM was compared with IVP measurement by t-testing and by calculating mean difference as well as limits of agreement (LA).</p> <p>Results</p> <p>There were no probe related complications. Due to technical limitations, data could be collected in 3/10 patients with Coach<sup>® </sup>and in 7/10 patients with Accurate++<sup>®</sup>. Analysis was carried out only for Accurate++<sup>®</sup>. Mean values did not differ to mean IVP values. Mean difference to IVP was 0.1 ± 2.8 mmHg (LA: -5.5 to 5.6 mmHg).</p> <p>Conclusion</p> <p>Direct IAP measurement was clinically uneventful. Although results of Accurate++<sup>® </sup>were comparable to IVP, the device might be too fragile for IAP measurements in the clinical setting. Local ethical committee trial registration: EK2024</p

    The effect of oxygen saturation targeting on retinal blood vessel growth using retinal image data from the BOOST-II UK Trial

    Get PDF
    Purpose: Retinopathy of prematurity (ROP) is a disorder of developing retinal blood vessels in preterm infants. The purpose of this nested study was to investigate the effects of higher (91-95%) and lower (85-89%) oxygen saturation (SpO2) targeting on retinal blood vessel growth in preterm infants. Methods: Retinal blood vessel growth in the higher (91-95%) and lower (85-89%) oxygen saturation (SpO2) targeting groups was compared. Suitable RetCam (Clarity, Pleasanton, CA, USA) images collected in the BOOST-II UK trial were used. The distances between the centre of the optic disc and the ROP ridge in the temporal and nasal retina were measured in pixel units. Results: Images from 38 infants were studied, 20 from the higher SpO2 target group and 18 from the lower SpO2 target group. On average, temporal blood vessels extended further from the optic disc than nasal blood vessels, mean (standard deviation (SD)) 463.39 (55.05) pixels compared with 360.13 (44.47) pixels, respectively, P&lt;0.0001. Temporal blood vessels extended less far from the optic disc in the higher SpO2 target group than in the lower SpO2 target group: mean (SD) 449.83 (56.16) pixels compared with 480.02 (49.94), respectively, P=0.055. Nasal retinal blood vessel measurements were broadly similar in the higher and lower SpO2 target groups; mean (SD) 353.96 (41.95) compared with 370.00 (48.82) pixels, respectively, P=0.38. Conclusions: Relatively high oxygen saturation targeting (91-95%) was associated with a trend (P=0.055) towards reduced retinal blood vessel growth in this study of preterm infants

    Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Visual estimation (VE) is an essential tool for evaluation of range of motion. Few papers discussed its validity in children orthopedics' practice. The purpose of our study was to assess validity and reliability of VE for passive range of motions (PROMs) of children's lower limbs.</p> <p>Methods</p> <p>Fifty typically developing children (100 lower limbs) were examined. Visual estimations for PROMs of hip (flexion, adduction, abduction, internal and external rotations), knee (flexion and popliteal angle) and ankle (dorsiflexion and plantarflexion) were made by a pediatric orthopaedic surgeon (POS) and a 5<sup>th </sup>year resident in orthopaedics. A last year medical student did goniometric measurements. Three weeks later, same measurements were performed to assess reliability of visual estimation for each examiner.</p> <p>Results</p> <p>Visual estimations of the POS were highly reliable for hip flexion, hip rotations and popliteal angle (ρ<sub>c </sub>≥ 0.8). Reliability was good for hip abduction, knee flexion, ankle dorsiflexion and plantarflexion (ρ<sub>c </sub>≥ 0.7) but poor for hip adduction (ρ<sub>c </sub>= 0.5). Reproducibility for all PROMs was verified. Resident's VE showed high reliability (ρ<sub>c </sub>≥ 0.8) for hip flexion and popliteal angle. Good correlation was found for hip rotations and knee flexion (ρ<sub>c </sub>≥ 0.7). Poor results were obtained for ankle PROMs (ρ<sub>c </sub>< 0.6) as well as hip adduction and abduction, the results of which not being reproducible. Influence of experience was clearly demonstrated for PROMs of hip rotations, adduction and abduction as well as ankle plantarflexion.</p> <p>Conclusion</p> <p>Accuracy of VE of passive hip flexion and knee PROMs is high regardless of the examiner's experience. Same accuracy can be found for hip rotations and abduction whenever VE is performed by an experienced examiner. Goniometric evaluation is recommended for passive hip adduction and for ankle PROMs.</p

    Long-term in-vitro precision of direct digital X-ray radiogrammetry

    Get PDF
    Digital X-ray radiogrammetry (DXR) calculates peripheral bone mineral density (BMD) from hand radiographs. The short-term precision for direct DXR has been reported to be highly satisfactory. However, long-term precision for this method has not been examined. Thus, the aim of this study was to examine the long-term in-vitro precision for the new direct digital version of DXR. The in-vitro precision for direct DXR was tested with cadaver phantoms on four different X-ray systems at baseline, 3 months, 6 months, and in one machine also at 12 months. At each time point, 31 measurements were performed. The in-vitro longitudinal precision for the four radiographic systems ranged from 0.22 to 0.43% expressed as coefficient of variation (CV%). The smallest detectable difference (SDD) ranged from 0.0034 to 0.0054 g/cm(2). The in vitro long-term precision for direct DXR was comparable to the previous reported short-term in-vitro precision for all tested X-ray systems. These data show that DXR is a stable method for detecting small changes in bone density during 6-12 months of follow-up
    corecore