107 research outputs found

    Temperature effects on the electrical performance of large area multicrystalline silicon solar cells using the current shunt measuring technique

    Get PDF
    The temperature effects on the electrical performance of a large area multicrystalline silicon solar cell with back-contact technology have been studied in a desert area under ambient conditions using the current shunt measuring technique. Therefore, most of the problems encountered with traditional measuring techniques are avoided. The temperature dependency of the current shunt from 5ºC up to 50ºC has been investigated. Its temperature coefficient proves to be negligible which means that the temperature dependency of the solar cell is completely independent of the current shunt. The solar module installed in a tilted position at the optimum angle of the location, has been tested in two different seasons (winter and summer). The obtained solar cell short circuit current, open circuit voltage and output power are correlated with the measured incident radiation in both seasons and all results are discussed

    An improved design of a fully automated multiple output micropotentiometer

    Get PDF
    This paper describes in details a new design of a fully automated multiple output micropotentiometer (?pot). A prototype has been built at the National Institute for Standards (NIS), Egypt to establish this highly improved AC voltage source in the millivolt range. The new device offers three different outputs covering a wide frequency range from only one outlet. This valuably supports the precise sourcing ranges of low AC voltage at NIS. The design and the operation theory of this prototype have been discussed in details. An automatic calibration technique has been introduced through specially designed software using the LabVIEW program to enhance the calibration technique and to reduce the uncertainty contributions. Relative small AC-DC differences of our prototype in the three output ranges are fairly verified. The expanded uncertainties of the calibration results for the three output ranges have been faithfully estimated. However, further work is needed to achieve the optimum performance of this new device

    Electrical performance study of a large area multicrystalline silicon solar cell using a current shunt and a micropotentiometer

    Get PDF
    In this paper, a new technique using a Current Shunt and a Micropotentiometer has been used to study the electrical performance of a large area multicrystalline silicon solar cell at outdoor conditions. The electrical performance is mainly described by measuring both cell short circuit current and open circuit voltage. The measurements of this cell by using multimeters suffer from some problems because the cell has high current intensity with low output voltage. So, the solar cell short circuit current values are obtained by measuring the voltage developed across a known resistance Current Shunt. Samples of the obtained current values are accurately calibrated by using a Micropotentiometer (μpot) thermal element (TE) to validate this new measuring technique. Moreover, the solar cell open circuit voltage has been measured. Besides, the cell output power has been calculated and can be correlated with the measured incident radiation

    Electrochemical Activation of Graphene at Low Temperature: The Synthesis of Three-Dimensional Nanoarchitectures for High Performance Supercapacitors and Capacitive Deionization

    Get PDF
    An electrochemical technique is developed to activate graphene oxide (GO) at relatively low temperature and assemble it into porous electrodes. The activation process is carried out in molten KOH by switching the polarity between 2 symmetrical GO electrodes. The electrochemically activated graphene (ECAG) showed a specific surface area as high as 2170 m<sup>2</sup> g<sup>–1</sup> and nanometer-sized pore created at a temperature as low as 450 °C. The ECAG electrode shows a significant enhancement in the electrochemical activity and thus improved electrochemical performance when being used as electrodes in supercapacitors and capacitive deionization (CDI) cells. A specific capacitance of 275 F g<sup>–1</sup> is obtained in 6 M KOH electrolyte, and 189 F g<sup>–1</sup> in 1 M NaCl electrolyte, which maintains 95% after 5000 cycles. The desalination capacity of the electrodes was evaluated by a batch mode electrosorption experiment. The ECAG electrode was able to remove 14.25 mg of salts per gram of the active materials and satisfy a high adsorption rate of 2.01 mg g<sup>–1</sup> min<sup>–1</sup>. The low energy consumption of the CDI system is demonstrated by its high charge efficiency, which is estimated to be 0.83

    Comparison of Microscopy and Alamar Blue Reduction in a Larval Based Assay for Schistosome Drug Screening

    Get PDF
    Only one drug, praziquantel, is widely available for treating schistosomiasis, a disease affecting an estimated 200 million people. Because of increasing usage there is concern about development of praziquantel drug resistance and a perceived need to develop new schistosomicides. Possible sources of these are large collections of compounds held by pharmaceutical companies and academic institutions. Anti-schistosome activity can be detected in vitro by visually assessing damage to cultured adult schistosome worms, but these are large and are recovered from mice which somewhat limits screening throughput. By contrast, schistosomula can be produced in vitro and used for screening in microwell plates, thus allowing medium throughput screening. High throughput screening (HTS) would require automated readout of schistosomulicidal action rather than manual microscopy. Here we report on the use of Alamar blue (AB), a fluorescent indicator of cell viability which can be measured rapidly and automatically. The AB assay was readily able to detect compounds causing death or severe damage to the larvae but was less reliable than microscopy for more subtle morphological changes including those induced by some known schistosome drugs. It is concluded that an automated HTS would benefit from integrated use of both AB and automatic image-based morphology assays

    Serum Islet Cell Autoantibodies During Interferon α Treatment in Patients With HCV-Genotype 4 Chronic Hepatitis

    Get PDF
    Chronic hepatitis C virus (HCV) infection is a leading cause of end-stage liver disease worldwide and HCV genotype 4 (HCV4) is predominant in African and Middle Eastern countries. It is well established that interferon-α (IFNa) treatment for HCV may trigger serum autoantibodies against pancreatic islet cells (ICA) in a subgroup of patients. Available data on the incidence of ICA during IFNa therapy for chronic HCV4 infection are not conclusive. We investigated the appearance of ICA in 40 naïve Egyptian patients (38 males, 32 ± 6 years) with histologically defined chronic HCV4 infection undergoing IFNa treatment at a dose of 9-million U/week for 24 weeks. Serum samples were collected at baseline and following IFNa therapy and ICA were detected using indirect immunofluorescence. Baseline evaluation indicated that 2/40 (5%) patients had detectable serum ICA. After the completion of the treatment scheme, 12/38 (32%) previously ICA negative patients became ICA positive; however, no patient developed impaired glucose tolerance (IGT) or diabetes during follow-up. In conclusion, we submit that IFNa treatment for chronic hepatitis C (CHC) may induce serum ICA in one-third of Egyptian patients with HCV4. These autoantibodies, however, do not lead to alterations in glucose metabolism
    • …
    corecore