91 research outputs found

    Multiscale correlative tomography: an investigation of creep cavitation in 316 stainless steel

    Get PDF
    Creep cavitation in an ex-service nuclear steam header Type 316 stainless steel sample is investigated through a multiscale tomography workflow spanning eight orders of magnitude, combining X-ray computed tomography (CT), plasma focused ion beam (FIB) scanning electron microscope (SEM) imaging and scanning transmission electron microscope (STEM) tomography. Guided by microscale X-ray CT, nanoscale X-ray CT is used to investigate the size and morphology of cavities at a triple point of grain boundaries. In order to understand the factors affecting the extent of cavitation, the orientation and crystallographic misorientation of each boundary is characterised using electron backscatter diffraction (EBSD). Additionally, in order to better understand boundary phase growth, the chemistry of a single boundary and its associated secondary phase precipitates is probed through STEM energy dispersive X-ray (EDX) tomography. The difference in cavitation of the three grain boundaries investigated suggests that the orientation of grain boundaries with respect to the direction of principal stress is important in the promotion of cavity formation

    Bronchogenic cyst associated with pericardial defect: Case report and review of the literature

    Get PDF
    Partial defect of the pericardium combined with bronchogenic cyst is a very rare congenital anomaly. We describe the case of a 32-year-old man with a partial defect of the left pericardium and a bronchogenic cyst arising from the border of the pericardial defect. The cyst was successfully resected with the harmonic scalpel by three-port videothoracoscopic approach

    Lack of robustness of textural measures obtained from 3D brain tumor MRIs impose a need for standardization

    Get PDF
    Purpose Textural measures have been widely explored as imaging biomarkers in cancer. However, their robustness under dynamic range and spatial resolution changes in brain 3D magnetic resonance images (MRI) has not been assessed. The aim of this work was to study potential variations of textural measures due to changes in MRI protocols. Materials and methods Twenty patients harboring glioblastoma with pretreatment 3D T1-weighted MRIs were included in the study. Four different spatial resolution combinations and three dynamic ranges were studied for each patient. Sixteen three-dimensional textural heterogeneity measures were computed for each patient and configuration including co-occurrence matrices (CM) features and run-length matrices (RLM) features. The coefficient of variation was used to assess the robustness of the measures in two series of experiments corresponding to (i) changing the dynamic range and (ii) changing the matrix size. Results No textural measures were robust under dynamic range changes. Entropy was the only textural feature robust under spatial resolution changes (coefficient of variation under 10% in all cases). Conclusion Textural measures of three-dimensional brain tumor images are not robust neither under dynamic range nor under matrix size changes. Standards should be harmonized to use textural features as imaging biomarkers in radiomic-based studies. The implications of this work go beyond the specific tumor type studied here and pose the need for standardization in textural feature calculation of oncological images

    Internal strains between grains during creep deformation of an austenitic stainless steel

    Get PDF
    Internal strains that develop between grains during creep of an austenitic stainless steel were measured using in situ neutron diffraction. The secondary creep pre-strained test specimens were considered. Measurements were undertaken before, during and post creep deformation at 550 °C. There was no measurable change of internal strains between grains during in situ creep for 4 h at 550 °C. In addition, the effect of increasing/reducing temperatures in a range from 470 to 550 °C on the internal strains was measured and interpreted with respect to contributions from thermal expansion/contraction. No further internal misfit strains between grains were created when specimen crept during the dwell time at 530, 510, 490 and 470 °C. Results are discussed with respect to (i) the general structure of self-consistent models and (ii) the optimised use of neutron sources for creep studies

    Disorders of intestinal rotation and fixation (“malrotation”)

    Full text link
    Malrotation with volvulus is one of the true surgical emergencies of childhood. Prompt radiological diagnosis is often paramount to achieving a good outcome. An understanding of the normal and anomalous development of the midgut provides a basis for understanding the pathophysiology and the clinical presentation of malrotation and malrotation complicated by volvulus. In this essay, the radiologic findings of malrotation and volvulus are reviewed and illustrated with particular attention to the child with equivocal imaging findings.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46708/1/247_2004_Article_1279.pd

    Shear Localization in Dynamic Deformation: Microstructural Evolution

    Full text link
    • …
    corecore