924 research outputs found

    THE INFLUENCE OF PASSIVE HIP EXTENSION ON RUNNING BIOMECHANICS

    Get PDF
    J. Stoewer1, E. Foch2, M.B Pohl1 1University of Puget Sound, Tacoma, WA; 2Central Washington University, Ellensburg, WA Restricted passive range of motion (PROM) of hip extension has been anecdotally linked with low back pain. A potential mechanism for this may be that restrictions in passive hip extension prevents the hip from fully extending during running. As a consequence, the pelvis may undergo anterior tilt to allow the thigh to extend, thus, resulting in greater loading of the lumbar spine. However, it is currently unclear whether restricted passive hip extension has any bearing on hip and pelvis biomechanics during running. PURPOSE: To determine whether runners who differ in passive hip extension also demonstrate differences in hip extension and anterior pelvic tilt during running. METHODS: Participants included 9 healthy runners (3 males, 6 females) between the ages of 18-28. Passive hip extension was measured using the Thomas Test. Kinematic data during running was collected using a 3D motion capture system. Subjects were split into three groups (tight, normal, & flexible) using tertiles based on their Thomas Test score. Both hip extension and anterior pelvic tilt during running were then compared between groups using Cohenā€™s effect sizes (ES). RESULTS: The tight group exhibited the least amount of hip extension during running with a large effect size (ES=0.84) when compared to the flexible group (Table 1). The tight group exhibited the greatest amount of anterior pelvic tilt with large effect sizes when compared to both the normal (ES=0.80) and flexible (ES=2.34) groups. CONCLUSION: Limited passive hip extension was linked with alterations in running biomechanics including reduced hip extension and greater anterior pelvic tilt. These kinematic alterations could potentially place greater loading the lumbar spine

    Changes in joint coupling and variability during walking following tibialis posterior muscle fatigue

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The tibialis posterior muscle is believed to play a key role in controlling foot mechanics during the stance phase of gait. However, an experiment involving localised tibialis posterior muscle fatigue, and analysis of discrete rearfoot and forefoot kinematic variables, indicated that reduced force output of the tibialis posterior muscle did not alter rearfoot and forefoot motion during gait. Thus, to better understand how muscle fatigue affects foot kinematics and injury potential, the purpose of this study was to reanalyze the data and investigate shank, rearfoot and forefoot joint coupling and coupling variability during walking.</p> <p>Methods</p> <p>Twenty-nine participants underwent an exercise fatigue protocol aimed at reducing the force output of tibialis posterior. An eight camera motion analysis system was used to evaluate 3 D shank and foot joint coupling and coupling variability during treadmill walking both pre- and post-fatigue.</p> <p>Results</p> <p>The fatigue protocol was successful in reducing the maximal isometric force by over 30% and a concomitant increase in coupling motion of the shank in the transverse plane and forefoot in the sagittal and transverse planes relative to frontal plane motion of the rearfoot. In addition, an increase in joint coupling variability was measured between the shank and rearfoot and between the rearfoot and forefoot during the fatigue condition.</p> <p>Conclusions</p> <p>The reduced function of the tibialis posterior muscle following fatigue resulted in a disruption in typical shank and foot joint coupling patterns and an increased variability in joint coupling. These results could help explain tibialis posterior injury aetiology.</p

    Hybrid Algorithms Based on Integer Programming for the Search of Prioritized Test Data in Software Product Lines

    Get PDF
    In Software Product Lines (SPLs) it is not possible, in general, to test all products of the family. The number of products denoted by a SPL is very high due to the combinatorial explosion of features. For this reason, some coverage criteria have been proposed which try to test at least all feature interactions without the necessity to test all products, e.g., all pairs of features (pairwise coverage). In addition, it is desirable to first test products composed by a set of priority features. This problem is known as the Prioritized Pairwise Test Data Generation Problem. In this work we propose two hybrid algorithms using Integer Programming (IP) to generate a prioritized test suite. The first one is based on an integer linear formulation and the second one is based on a integer quadratic (nonlinear) formulation. We compare these techniques with two state-of-the-art algorithms, the Parallel Prioritized Genetic Solver (PPGS) and a greedy algorithm called prioritized-ICPL. Our study reveals that our hybrid nonlinear approach is clearly the best in both, solution quality and computation time. Moreover, the nonlinear variant (the fastest one) is 27 and 42 times faster than PPGS in the two groups of instances analyzed in this work.Universidad de MƔlaga. Campus de Excelencia Internacional Andalucƭa Tech. Partially funded by the Spanish Ministry of Economy and Competitiveness and FEDER under contract TIN2014-57341-R, the University of MƔlaga, Andalucƭa Tech and the Spanish Network TIN2015-71841-REDT (SEBASENet)

    The role of tibialis posterior fatigue on foot kinematics during walking

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study was to investigate the effect of localised tibialis posterior muscle fatigue on foot kinematics during walking. It was hypothesised that following fatigue, subjects would demonstrate greater forefoot and rearfoot motion during walking. It was also postulated that the magnitude of the change in rearfoot motion would be associated with standing anatomical rearfoot posture.</p> <p>Methods</p> <p>Twenty-nine subjects underwent an exercise fatigue protocol aimed at reducing the force output of tibialis posterior. An eight camera motion analysis system was used to evaluate 3D foot kinematics during treadmill walking both pre- and post-fatigue. The anatomical rearfoot angle was measured during standing prior to the fatigue protocol using a goniometer.</p> <p>Results</p> <p>Peak rearfoot eversion remained unchanged following the fatigue protocol. Although increases in rearfoot eversion excursion were observed following fatigue, these changes were of a magnitude of questionable clinical significance (<1.0Ā°). The magnitude of the change in rearfoot eversion due to fatigue was not associated with the anatomical measurement of standing rearfoot angle. No substantial changes in forefoot kinematics were observed following the fatigue protocol.</p> <p>Conclusions</p> <p>These data indicate that reduced force output of the tibialis posterior muscle did not alter rearfoot and forefoot motion during gait. The anatomical structure of the rearfoot was not associated with the dependence of muscular activity that an individual requires to maintain normal rearfoot kinematics during gait.</p

    Probe-Based Confocal Laser Endomicroscopy to Guide Real-Time Endoscopic Therapy in Barrett's Esophagus with Dysplasia

    Get PDF
    Probe-based confocal laser endomicroscopy (pCLE) is a novel imaging technique which utilizes a low-power laser light passed through a fiber-optic bundle, within a miniprobe that is advanced into the working channel, to obtain microscopic images of the mucosa. This allows the endoscopist to evaluate the microarchitecture of the gastrointestinal epithelium in real time. At this time pCLE cannot replace histopathology, but it can provide diagnostic information as well as guide therapeutic management in patients with Barrett's esophagus (BE) with high-grade dysplasia (HGD). We describe a retrospective case series in which four patients with BE and biopsy-proven HGD underwent endoscopy with pCLE to direct real-time endoscopic ablation therapy and/or endoscopic mucosal resection (EMR), which was performed in conjunction with pCLE. All four patients had pCLE showing features of HGD. After either EMR or radiofrequency ablation (RFA), pCLE was again used to evaluate the margins after therapy to assure accuracy. In one case, pCLE had features of dysplasia at the margin and further repeat EMR was immediately performed. Another case had a normal-appearing esophagus, but pCLE found features of BE in discrete areas and targeted biopsies were performed, which confirmed BE. This patient subsequently underwent RFA therapy of the residual areas of BE. In conclusion, in patients with BE and dysplasia, pCLE is an effective tool used to target biopsies, guide endoscopic therapy and assess the accuracy of EMR or RFA

    Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    Get PDF
    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results

    Cancer somatic mutations cluster in a subset of regulatory sites predicted from the ENCODE data

    Get PDF
    Background: Transcriptional regulation of gene expression is essential for cellular differentiation and function, and defects in the process are associated with cancer. The ENCODE project has mapped potential regulatory sites across the complete genome in many cell types, and these regions have been shown to harbour many of the somatic mutations that occur in cancer cells, suggesting that their effects may drive cancer initiation and development. The ENCODE data suggests a very large number of regulatory sites, and methods are needed to identify those that are most relevant and to connect them to the genes that they control. Methods: Predictive models of gene expression were developed by integrating the ENCODE data for regulation, including transcription factor binding and DNase1 hypersensitivity, with RNA-seq data for gene expression. A penalized regression method was used to identify the most predictive potential regulatory sites for each transcript. Known cancer somatic mutations from the COSMIC database were mapped to potential regulatory sites, and we examined differences in the mapping frequencies associated with sites chosen in regulatory models and other (rejected) sites. The effects of potential confounders, for example replication timing, were considered. Results: Cancer somatic mutations preferentially occupy those regulatory regions chosen in our models as most predictive of gene expression. Conclusion: Our methods have identified a significantly reduced set of regulatory sites that are enriched in cancer somatic mutations and are more predictive of gene expression. This has significance for the mechanistic interpretation of cancer mutations, and the understanding of genetic regulation

    Changes in multi-segment foot biomechanics with a heat-mouldable semi-custom foot orthotic device

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Semi-custom foot orthoses (SCO) are thought to be a cost-effective alternative to custom-made devices. However, previous biomechanical research involving either custom or SCO has only focused on rearfoot biomechanics. The purpose of this study was therefore to determine changes in multi-segment foot biomechanics during shod walking with and without an SCO. We chose to investigate an SCO device that incorporates a heat-moulding process, to further understand if the moulding process would significantly alter rearfoot, midfoot, or shank kinematics as compared to a no-orthotic condition. We hypothesized the SCO, whether moulded or non-moulded, would reduce peak rearfoot eversion, tibial internal rotation, arch deformation, and plantar fascia strain as compared to the no-orthoses condition.</p> <p>Methods</p> <p>Twenty participants had retroreflective markers placed on the right limb to represent forefoot, midfoot, rearfoot and shank segments. 3D kinematics were recorded using an 8-camera motion capture system while participants walked on a treadmill.</p> <p>Results</p> <p>Plantar fascia strain was reduced by 34% when participants walked in either the moulded or non-moulded SCO condition compared to no-orthoses. However, there were no significant differences in peak rearfoot eversion, tibial internal rotation, or medial longitudinal arch angles between any conditions.</p> <p>Conclusions</p> <p>A semi-custom moulded orthotic does not control rearfoot, shank, or arch deformation but does, however, reduce plantar fascia strain compared to walking without an orthoses. Heat-moulding the orthotic device does not have a measurable effect on any biomechanical variables compared to the non-moulded condition. These data may, in part, help explain the clinical efficacy of orthotic devices.</p

    Oxidants, antioxidants, and respiratory tract lining fluids.

    Get PDF
    Respiratory tract lining fluids (RTLFs) are a heterogeneous group of substances covering the respiratory tract epithelial cells (RTECs) from nasal mucosa to alveoli. Antioxidant contained in the RTLFs can be expected to provide an initial defense against inhaled environmental toxins. The major antioxidants in RTLF include mucin, uric acid, protein (largely albumin), ascorbic acid, and reduced glutathione (GSH). RTLF antioxidants can be augmented by such processes as transudation/exudation of plasma constituents; RTEC secretory processes, including glandular mucus secretion; and cellular antioxidants derived from lysis of RTECs and of inflammatory cells. The antioxidant composition of RTLFs and their role in modulating normal and pathophysiologic RTEC functions under conditions of oxidative stress are yet to be fully characterized
    • ā€¦
    corecore