16 research outputs found

    Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report

    Get PDF
    This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability

    Test-Retest Variability and Discriminatory Power of Measurements From Microperimetry and Dark Adaptation Assessment in People With Intermediate Age-Related Macular Degeneration – A MACUSTAR Study Report

    Get PDF
    Purpose: The purpose of this study was to assess test-retest variability and discriminatory power of measures from macular integrity assessment (S-MAIA) and AdaptDx. // Methods: This is a cross-sectional study of 167 people with intermediate age-related macular degeneration (iAMD), no AMD (controls; n = 54), early AMD (n = 28), and late AMD (n = 41), recruited across 18 European ophthalmology centers. Repeat measures of mesopic and scotopic S-MAIA average (mean) threshold (MMAT decibels [dB] and SMAT [dB]) and rod intercept time (RIT [mins]) at 2 visits 14 (±7) days apart were recorded. Repeat measures were assessed by Bland-Altman analysis, intra-class correlation coefficients (ICCs) and variability ratios. Secondary analysis assessed the area under the receiver operating characteristic curves (AUC) to determine the ability to distinguish people as having no AMD, early AMD, or iAMD. // Results: Data were available for 128, 131, and 103 iAMD participants for the mesopic and scotopic S-MAIA and AdaptDx, respectively. MMAT and SMAT demonstrate similar test-retest variability in iAMD (95% confidence interval [CI] ICC of 0.79–0.89 and 0.78–0.89, respectively). ICCs were worse in RIT (95% CI ICC = 0.55–0.77). All tests had equivalent AUCs (approximately 70%) distinguishing between subjects with iAMD and controls, whereas early AMD was indistinguishable from iAMD on all measures (AUC = <55%). A learning effect was not seen in these assessments under the operating procedures used. // Conclusions: MMAT, SMAT, and RIT have adequate test-retest variability and are all moderately good at separating people with iAMD from controls. // Translational Relevance: Expected levels of test-retest variability and discriminatory power of the AdaptDx and MAIA devices in a clinical study setting must be considered when designing future trials for people with AMD

    Disease-specific assessment of Vision Impairment in Low Luminance (VILL) in age-related macular degeneration – a MACUSTAR study report

    Get PDF
    Background/Aims: To further validate the Vision Impairment in Low Luminance (VILL) questionnaire, which captures visual functioning and vision-related quality of life under low luminance, low contrast conditions relevant to age-related macular degeneration (AMD). Methods: The VILL was translated from German into English (UK), Danish, Dutch, French, Italian and Portuguese. Rasch analysis was used to assess psychometric characteristics of 716 participants (65% female, mean age 72±7 years, 82% intermediate AMD) from the baseline visit of the MACUSTAR study. In a sub-set of participants (n=301), test-retest reliability (intra-class correlation coefficient, ICC; coefficient of repeatability, CoR) and construct validity were assessed. Results: Four items were removed from the VILL-37 due to misfit. The resulting VILL-33 has three subscales with no disordered thresholds and no misfitting items. No differential item functioning and no multidimensionality were observed. Person reliability and person separation index were 0.91 and 3.27 for the reading subscale (VILL-R), 0.87 and 2.58 for the mobility subscale (VILL-M) and 0.78 and 1.90 for the emotional subscale (VILL-E). ICC and CoR were 0.92 and 1.9 for VILL-R, 0.93 and 1.8 for VILL-M and 0.82 and 5.0 for VILL-E. Reported visionrelated quality of life decreased with advanced AMD stage (p<0.0001) and was lower in the intermediate AMD group than in the no AMD group (p≤0.0053). Conclusion: The VILL is a psychometrically sound patient-reported outcome instrument and the results further support its reliability and validity across all AMD stages. We recommend the shortened version of the questionnaire with three subscales (VILL-33) for future use. Trial registration number NCT03349801

    Challenges, facilitators and barriers to screening study participants in early disease stages-experience from the MACUSTAR study

    Get PDF
    BACKGROUND: Recruiting asymptomatic participants with early disease stages into studies is challenging and only little is known about facilitators and barriers to screening and recruitment of study participants. Thus we assessed factors associated with screening rates in the MACUSTAR study, a multi-centre, low-interventional cohort study of early stages of age-related macular degeneration (AMD). METHODS: Screening rates per clinical site and per week were compiled and applicable recruitment factors were assigned to respective time periods. A generalized linear mixed-effects model including the most relevant recruitment factors identified via in-depth interviews with study personnel was fitted to the screening data. Only participants with intermediate AMD were considered. RESULTS: A total of 766 individual screenings within 87 weeks were available for analysis. The mean screening rate was 0.6 ± 0.9 screenings per week among all sites. The participation at investigator teleconferences (relative risk increase 1.466, 95% CI [1.018-2.112]), public holidays (relative risk decrease 0.466, 95% CI [0.367-0.591]) and reaching 80% of the site's recruitment target (relative risk decrease 0.699, 95% CI [0.367-0.591]) were associated with the number of screenings at an individual site level. CONCLUSIONS: Careful planning of screening activities is necessary when recruiting early disease stages in multi-centre observational or low-interventional studies. Conducting teleconferences with local investigators can increase screening rates. When planning recruitment, seasonal and saturation effects at clinical site level need to be taken into account. TRIAL REGISTRATION: ClinicalTrials.gov NCT03349801 . Registered on 22 November 2017

    Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report

    No full text
    Abstract This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability
    corecore