48 research outputs found

    Lateral entorhinal cortex lesions impair odor-context associative memory in male rats

    Get PDF
    This work was supported by the Biotechnology and Biological Sciences Research Council (BBSRC) [grant number BB/M010996/1].Lateral entorhinal cortex (LEC) has been hypothesized to process nonspatial, item information that is combined with spatial information from medial entorhinal cortex to form episodic memories within the hippocampus. Recent studies, however, have demonstrated that LEC has a role in integrating features of episodic memory prior to the hippocampus. While the precise role of LEC is still unclear, anatomical studies show that LEC is ideally placed to be a hub integrating multisensory information. The current study tests whether the role of LEC in integrating information extends to long-term multimodal item-context associations. In Experiment 1, male rats were trained on a context-dependent odor discrimination task, where two different contexts served as the cue to the correct odor. Rats were pretrained on the task and then received either bilateral excitotoxic LEC or sham lesions. Following surgery, rats were tested on the previously learned odor-context associations. Control rats showed good memory for the previously learned association but rats with LEC lesions showed significantly impaired performance relative to both their own presurgery performance and to control rats. Experiment 2 went on to test whether impairments in Experiment 1 were the result of LEC lesions impairing either odor or context memory retention alone. Male rats were trained on simple odor and context discrimination tasks that did not require integration of features to solve. Following surgery, both LEC and control rats showed good memory for previously learned odors and contexts. These data show that LEC is critical for long-term odor-context associative memory.Publisher PDFPeer reviewe

    Whole genome sequence of the Treponema Fribourg- Blanc: Unspecified simian isolate is highly similar to the yaws subspecies

    Get PDF
    BACKGROUND:Unclassified simian strain Treponema Fribourg-Blanc was isolated in 1966 from baboons (Papio cynocephalus) in West Africa. This strain was morphologically indistinguishable from T. pallidum ssp. pallidum or ssp. pertenue strains, and it was shown to cause human infections. METHODOLOGY/PRINCIPAL FINDINGS:To precisely define genetic differences between Treponema Fribourg-Blanc (unclassified simian isolate, FB) and T. pallidum ssp. pertenue strains (TPE), a high quality sequence of the whole Fribourg-Blanc genome was determined with 454-pyrosequencing and Illumina sequencing platforms. Combined average coverage of both methods was greater than 500×. Restriction target sites (n = 1,773), identified in silico, of selected restriction enzymes within the Fribourg-Blanc genome were verified experimentally and no discrepancies were found. When compared to the other three sequenced TPE genomes (Samoa D, CDC-2, Gauthier), no major genome rearrangements were found. The Fribourg-Blanc genome clustered with other TPE strains (especially with the TPE CDC-2 strain), while T. pallidum ssp. pallidum strains clustered separately as well as the genome of T. paraluiscuniculi strain Cuniculi A. Within coding regions, 6 deletions, 5 insertions and 117 substitutions differentiated Fribourg-Blanc from other TPE genomes. CONCLUSIONS/SIGNIFICANCE:The Fribourg-Blanc genome showed similar genetic characteristics as other TPE strains. Therefore, we propose to rename the unclassified simian isolate to Treponema pallidum ssp. pertenue strain Fribourg-Blanc. Since the Fribourg-Blanc strain was shown to cause experimental infection in human hosts, non-human primates could serve as possible reservoirs of TPE strains. This could considerably complicate recent efforts to eradicate yaws. Genetic differences specific for Fribourg-Blanc could then contribute for identification of cases of animal-derived yaws infections

    Comparison of Cosmic Radiation Detectors in the Radiation Field at Aviation Altitudes

    Get PDF
    An assessment of the exposure of aircrew and passengers to the complex radiation field at aviation altitudes has been a challenging task and a legal obligation in the European Union for many years. The response of several radiation measuring instruments to this radiation field was investigated by different European research groups within the framework of the CONCORD campaign (COmparisoN of COsmic Radiation Detectors) in the Radiation Field at Aviation Altitudes. We measured dose rates at four positions in the atmosphere in European airspace, two altitudes at two locations respectively, under quiet space weather conditions during joint measuring flights with the twin-jet research aircraft Dassault Falcon 20E operated by the DLR flight facility Oberpfaffenhofen. The results show a very good agreement between the readings of the instruments of the different research groups as well as for the comparison of the corresponding average values with PANDOCA model calculations

    CONCORD: comparison of cosmic radiation detectors in the radiation field at aviation altitudes

    Get PDF
    Space weather can strongly affect the complex radiation field at aviation altitudes. The assessment of the corresponding radiation exposure of aircrew and passengers has been a challenging task as well as a legal obligation in the European Union for many years. The response of several radiation measuring instruments operated by different European research groups during joint measuring flights was investigated in the framework of the CONCORD (COmparisoN of COsmic Radiation Detectors) campaign in the radiation field at aviation altitudes. This cooperation offered the opportunity to measure under the same space weather conditions and contributed to an independent quality control among the participating groups. The CONCORD flight campaign was performed with the twin-jet research aircraft Dassault Falcon 20E operated by the flight facility Oberpfaffenhofen of the German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt, DLR). Dose rates were measured at four positions in the atmosphere in European airspace for about one hour at each position in order to obtain acceptable counting statistics. The analysis of the space weather situation during the measuring flights demonstrates that short-term solar activity did not affect the results which show a very good agreement between the readings of the instruments of the different institutes

    Microdosimetry for a carbon ion beam using track-etched detectors

    No full text
    Track-etched detectors (TED) have been used as linear energy transfer (LET) spectrometers in heavy ion beams for many years. LET spectra and depth-dose distribution of a carbon ion beam were measured behind polymethylmethacrylate degraders at Heavy Ion Medical Accelerator in Chiba, Japan. The measurements were performed along monoenergetic beam with energy 290 MeV u-1 in different positions: (1) at beam extraction area, (2) at beginning, (3) maximum and (4) behind the Bragg peak region (0, 117, 147 and 151 mm of water-equivalent depth, respectively). The LET spectra inside and outside of the primary ion beam have been evaluated. TED record only heavy charged particles with LET above 8-10 keV μm-1, while electrons and ions with lower LET are not detected. The Geant4 simulation toolkit version 4.9.6.P01 has been used to estimate the contribution of non-detected particles to absorbed dose. Presented results demonstrate the applicability of TED for microdosimetry measurements in therapeutic carbon ion beams

    Dose Distribution Outside the Target Volume for 170-Mev Proton Beam

    No full text
    Dose delivered outside the proton field during radiotherapy can potentially lead to secondary cancer development. Measurements with a 170-MeV proton beam were performed with passive detectors (track etched detectors and thermoluminescence dose-meters) in three different depths along the Bragg curve. The measurement showed an uneven decrease of the dose outside of the beam field with local enhancements. The major contribution to the delivered dose is due to high-energy protons with linear energy transfer (LET) up to 10 keV mu m(-1). However, both measurement and preliminary Monte Carlo calculation also confirmed the presence of particles with higher LET

    Liulin silicon semiconductor spectrometers as cosmic ray monitors at the high mountain observatories Jungfraujoch and Lomnický stit

    No full text
    Currently, most cosmic ray data are obtained by detectors on satellites, aircraft, high-altitude balloons and ground (neutron monitors). In our work, we examined whether Liulin semiconductor spectrometers (simple silicon planar diode detectors with spectrometric properties) located at high mountain observatories could contribute new information to the monitoring of cosmic rays by analyzing data from selected solar events between 2005 and 2013. The decision thresholds and detection limits of these detectors placed at Jungfraujoch (Switzerland; 3475 m a.s.l.; vertical cut-off rigidity 4.5 GV) and Lomnicky stıt (Slovakia; 2633 m a.s.l.; vertical cut-off rigidity 3.84 GV) highmountain observatories were determined. The data showed that only the strongest variations of the cosmic ray flux in this period were detectable. The main limitation in the performance of these detectors is their small sensitive volume and low sensitivity of the PIN photodiode to neutrons

    Radiation Environment at Aviation Altitudes and in Space

    No full text
    On the Earth, protection from cosmic radiation is provided by the magnetosphere and the atmosphere, but the radiation exposure increases with increasing altitude. Aircrew and especially space crew members are therefore exposed to an increased level of ionising radiation. Dosimetry onboard aircraft and spacecraft is however complicated by the presence of neutrons and high linear energy transfer particles. Film and thermoluminescent dosimeters, routinely used for ground-based personnel, do not reliably cover the range of particle types and energies found in cosmic radiation. Further, the radiation field onboard aircraft and spacecraft is not constant; its intensity and composition change mainly with altitude, geomagnetic position and solar activity (marginally also with the aircraft/spacecraft type, number of people aboard, amount of fuel etc.). The European Union Council directive 96/29/Euroatom of 1996 specifies that aircrews that could receive dose of >1 mSv y(-1) must be evaluated. The dose evaluation is routinely performed by computer programs, e.g. CARI-6, EPCARD, SIEVERT, PCAire, JISCARD and AVIDOS. Such calculations should however be carefully verified and validated. Measurements of the radiation field in aircraft are thus of a great importance. A promising option is the long-term deployment of active detectors, e.g. silicon spectrometer Liulin, TEPC Hawk and pixel detector Timepix. Outside the Earth\u27s protective atmosphere and magnetosphere, the environment is much harsher than at aviation altitudes. In addition to the exposure to high energetic ionising cosmic radiation, there are microgravity, lack of atmosphere, psychological and psychosocial components etc. The milieu is therefore very unfriendly for any living organism. In case of solar flares, exposures of spacecraft crews may even be lethal. In this paper, long-term measurements of the radiation environment onboard Czech aircraft performed with the Liulin since 2001, as well as measurements and simulations of dose rates on and outside the International Space Station were presented. The measured and simulated results are discussed in the context of health impact
    corecore