292 research outputs found

    Radio-frequency magnetometry using a single electron spin

    Full text link
    We experimentally demonstrate a simple and robust protocol for the detection of weak radio-frequency magnetic fields using a single electron spin in diamond. Our method relies on spin locking, where the Rabi frequency of the spin is adjusted to match the MHz signal frequency. In a proof-of-principle experiment we detect a 7.5 MHz magnetic probe field of 40 nT amplitude with <10 kHz spectral resolution over a T_1-limited noise floor of 0.3 nT/rtHz. Rotating-frame magnetometry may provide a direct and sensitive route to high-resolution spectroscopy of nanoscale nuclear spin signals

    Spurious harmonic response of multipulse quantum sensing sequences

    Full text link
    Multipulse sequences based on Carr-Purcell decoupling are frequently used for narrow-band signal detection in single spin magnetometry. We have analyzed the behavior of multipulse sensing sequences under real-world conditions, including finite pulse durations and the presence of detunings. We find that these non-idealities introduce harmonics to the filter function, allowing additional frequencies to pass the filter. In particular, we find that the XY family of sequences can generate signals at the 2fac, 4fac and 8fac harmonics and their odd subharmonics, where fac is the ac signal frequency. Consideration of the harmonic response is especially important for diamond-based nuclear spin sensing where the NMR frequency is used to identify the nuclear spin species, as it leads to ambiguities when several isotopes are present.Comment: 6 pages, 7 figure

    Henrietta : Valse De Salon

    Get PDF
    https://digitalcommons.library.umaine.edu/mmb-ps/1557/thumbnail.jp

    Investigation of Surface Magnetic Noise by Shallow Spins in Diamond

    Get PDF
    We present measurements of spin relaxation times (T1, T1ρ, T2) on very shallow (≲5  nm) nitrogen-vacancy centers in high-purity diamond single crystals. We find a reduction of spin relaxation times up to 30 times compared to bulk values, indicating the presence of ubiquitous magnetic impurities associated with the surface. Our measurements yield a density of 0.01–0.1μB/nm2 and a characteristic correlation time of 0.28(3) ns of surface states, with little variation between samples and chemical surface terminations. A low temperature measurement further confirms that fluctuations are thermally activated. The data support the atomistic picture where impurities are associated with the top carbon layers, and not with terminating surface atoms or adsorbate molecules. The low spin density implies that the presence of A single surface impurity is sufficient to cause spin relaxation of a shallow nitrogen-vacancy center

    Modelling the bronchial barrier in pulmonary drug delivery: A human bronchial epithelial cell line supplemented with human tracheal mucus.

    Get PDF
    The airway epithelium together with the mucus layer coating it forms a protective system that efficiently filters and removes potentially harmful particles contained in inhaled air. The same mechanism, however, serves to entrap particulate drug carriers, precluding their interaction with their target. The mucus barrier is often neglected in in vitro testing setups employed for the assessment of pulmonary drug delivery strategies. Therefore, our aim was to more accurately model the bronchial barrier, by developing an in vitro system comprising a tight epithelial cell layer which may be optionally supplemented with a layer of human tracheal mucus. To form the epithelium in vitro, we used the cystic fibrosis cell line CFBE41o-, which can be grown as monolayers on Transwell® supports, expressing tight junctions as well as relevant transport proteins. In contrast to the cell line Calu-3, however, CFBE41o- does not produce mucus. Therefore, native human mucus, obtained from tracheal tubes of patients undergoing elective surgery, was used as a supplement. The compatibility of CFBE41o- cells with the human mucus was addressed with the MTT assay, and confirmed by fluorescein diacetate/propidium iodide live/dead staining. Moreover, the CFBE41o- cells retained their epithelial barrier properties after being supplemented with mucus, as evidenced by the high trans-epithelial electrical resistance values (∼1000Ωcm(2)) together with a continued low level of paracellular transport of sodium fluorescein. Fluorescently-labeled chitosan-coated PLGA nanoparticles (NP, ∼168nm) were used as a model drug delivery system to evaluate the suitability of this in vitro model for studying mucus permeation and cell uptake. Comparing CFBE41o- cell monolayers with and without mucus, resp., showed that the NP uptake was dramatically reduced in the presence of mucus. This model may therefore be used as a tool to study potential mucus interactions of aerosolized drugs, and more specifically NP-based drug delivery systems designed to exert their effect in the bronchial region

    Nanoscale nuclear magnetic resonance with a 1.9-nm-deep nitrogen-vacancy sensor

    Get PDF
    We present nanoscale nuclear magnetic resonance (NMR) measurements performed with nitrogen-vacancy (NV) centers located down to about 2 nm from the diamond surface. NV centers were created by shallow ion implantation followed by a slow, nanometer-by-nanometer removal of diamond material using oxidative etching in air. The close proximity of NV centers to the surface yielded large 1H NMR signals of up to 3.4 lT-rms, corresponding to ~330 statistically polarized or ~10 fully polarized proton spins in a (1.8 nm)3 detection volume

    Bioinspired Liposomes for Oral Delivery of Colistin to Combat Intracellular Infections by Salmonella enterica.

    Get PDF
    Bacterial invasion into eukaryotic cells and the establishment of intracellular infection has proven to be an effective means of resisting antibiotic action, as anti-infective agents commonly exhibit a poor permeability across the host cell membrane. Encapsulation of anti-infectives into nanoscaled delivery systems, such as liposomes, is shown to result in an enhancement of intracellular delivery. The aim of the current work is, therefore, to formulate colistin, a poorly permeable anti-infective, into liposomes suitable for oral delivery, and to functionalize these carriers with a bacteria-derived invasive moiety to enhance their intracellular delivery. Different combinations of phospholipids and cholesterol are explored to optimize liposomal drug encapsulation and stability in biorelevant media. These liposomes are then surface-functionalized with extracellular adherence protein (Eap), derived from Staphylococcus aureus. Treatment of HEp-2 and Caco-2 cells infected with Salmonella enterica using colistin-containing, Eap-functionalized liposomes resulted in a significant reduction of intracellular bacteria, in comparison to treatment with nonfunctionalized liposomes as well as colistin alone. This indicates that such bio-invasive carriers are able to facilitate intracellular delivery of colistin, as necessary for intracellular anti-infective activity. The developed Eap-functionalized liposomes, therefore, present a promising strategy for improving the therapy of intracellular infections

    The management of diabetic foot: A clinical practice guideline by the Society for Vascular Surgery in collaboration with the American Podiatric Medical Association and the Society for Vascular Medicine

    Get PDF
    BACKGROUND: Diabetes mellitus continues to grow in global prevalence and to consume an increasing amount of health care resources. One of the key areas of morbidity associated with diabetes is the diabetic foot. To improve the care of patients with diabetic foot and to provide an evidence-based multidisciplinary management approach, the Society for Vascular Surgery in collaboration with the American Podiatric Medical Association and the Society for Vascular Medicine developed this clinical practice guideline. METHODS: The committee made specific practice recommendations using the Grades of Recommendation Assessment, Development, and Evaluation system. This was based on five systematic reviews of the literature. Specific areas of focus included (1) prevention of diabetic foot ulceration, (2) off-loading, (3) diagnosis of osteomyelitis, (4) wound care, and (5) peripheral arterial disease. RESULTS: Although we identified only limited high-quality evidence for many of the critical questions, we used the best available evidence and considered the patients' values and preferences and the clinical context to develop these guidelines. We include preventive recommendations such as those for adequate glycemic control, periodic foot inspection, and patient and family education. We recommend using custom therapeutic footwear in high-risk diabetic patients, including those with significant neuropathy, foot deformities, or previous amputation. In patients with plantar diabetic foot ulcer (DFU), we recommend off-loading with a total contact cast or irremovable fixed ankle walking boot. In patients with a new DFU, we recommend probe to bone test and plain films to be followed by magnetic resonance imaging if a soft tissue abscess or osteomyelitis is suspected. We provide recommendations on comprehensive wound care and various débridement methods. For DFUs that fail to improve (>50% wound area reduction) after a minimum of 4 weeks of standard wound therapy, we recommend adjunctive wound therapy options. In patients with DFU who have peripheral arterial disease, we recommend revascularization by either surgical bypass or endovascular therapy. CONCLUSIONS: Whereas these guidelines have addressed five key areas in the care of DFUs, they do not cover all the aspects of this complex condition. Going forward as future evidence accumulates, we plan to update our recommendations accordingly
    corecore