1,536 research outputs found

    Applying the Common Sense Model to predicting quality of life in alopecia areata: The role of illness perceptions and coping strategies

    Get PDF
    Item does not contain fulltextApplying the Common Sense Model, this cross-sectional study examines associations between illness perceptions and quality of life and the mediating role of coping in 243 adults with alopecia areata, a chronic dermatological condition. At least some QoL impairment was reported by 84 percent of participants, with 31 percent reporting very to extremely large impairment. Stronger perceptions of consequences, emotional representations, identity, and lower attribution to chance were related to more impairment, with avoidant coping acting as (partial) mediator. Illness perceptions and avoidant coping seem to play an important role in QoL and are relevant intervention targets in alopecia areata

    The Best of Both Worlds: Model-Driven Engineering Meets Model-Based Testing

    Get PDF
    We study the connection between stable-failures refinement and the ioco conformance relation. Both behavioural relations underlie methodologies that have gained traction in industry: stable-failures refinement is used in several commercial Model-Driven Engineering tool suites, whereas the ioco conformance relation is used in Model-Based Testing tools. Refinement-based Model-Driven Engineering approaches promise to generate executable code from high-level models, thus guaranteeing that the code upholds specified behavioural contracts. Manual testing, however, is still required to gain confidence that the model-to-code transformation and the execution platform do not lead to unexpected contract violations. We identify conditions under which also this last step in the design methodology can be automated using the ioco conformance relation and the associated tools

    Economics and Business Handbook 2009

    Get PDF
    In recent years a rising amount of randomized controlled trials, reviews, and meta-analyses relating to the efficacy of electroencephalographic-neurofeedback (EEG-NF) in children with attention-deficit/hyperactivity disorder (ADHD) have been published. Although clinical reports and open treatment studies suggest EEG-NF to be effective, double blind placebo-controlled studies as well as a rigorous meta-analysis failed to find support for the efficacy of EEG-NF. Since absence of evidence does not equate with evidence of absence, we will outline how future research might overcome the present methodological limitations. To provide conclusive evidence for the presence or absence of the efficacy of EEG-NF in the treatment of ADHD, there is a need to set up a well-designed study that ensures optimal implementation and embedding of the training, and possibly incorporates different forms of neurofeedback

    Intra-assessor reliability and measurement error of ultrasound measures for foot muscle morphology in older adults using a tablet-based ultrasound machine

    Get PDF
    BACKGROUND: To gain insight into the role of plantar intrinsic foot muscles in fall-related gait parameters in older adults, it is fundamental to assess foot muscles separately. Ultrasonography is considered a promising instrument to quantify the strength capacity of individual muscles by assessing their morphology. The main goal of this study was to investigate the intra-assessor reliability and measurement error for ultrasound measures for the morphology of selected foot muscles and the plantar fascia in older adults using a tablet-based device. The secondary aim was to compare the measurement error between older and younger adults and between two different ultrasound machines. METHODS: Ultrasound images of selected foot muscles and the plantar fascia were collected in younger and older adults by a single operator, intensively trained in scanning the foot muscles, on two occasions, 1–8 days apart, using a tablet-based and a mainframe system. The intra-assessor reliability and standard error of measurement for the cross-sectional area and/or thickness were assessed by analysis of variance. The error variance was statistically compared across age groups and machines. RESULTS: Eighteen physically active older adults (mean age 73.8 (SD: 4.9) years) and ten younger adults (mean age 21.9 (SD: 1.8) years) participated in the study. In older adults, the standard error of measurement ranged from 2.8 to 11.9%. The ICC ranged from 0.57 to 0.97, but was excellent in most cases. The error variance for six morphology measures was statistically smaller in younger adults, but was small in older adults as well. When different error variances were observed across machines, overall, the tablet-based device showed superior repeatability. CONCLUSIONS: This intra-assessor reliability study showed that a tablet-based ultrasound machine can be reliably used to assess the morphology of selected foot muscles in older adults, with the exception of plantar fascia thickness. Although the measurement errors were sometimes smaller in younger adults, they seem adequate in older adults to detect group mean hypertrophy as a response to training. A tablet-based ultrasound device seems to be a reliable alternative to a mainframe system. This advocates its use when foot muscle morphology in older adults is of interest. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13047-022-00510-1

    The effect of interventions anticipated to improve plantar intrinsic foot muscle strength on fall-related dynamic function in adults:A systematic review

    Get PDF
    BACKGROUND: The plantar intrinsic foot muscles (PIFMs) have a role in dynamic functions, such as balance and propulsion, which are vital to walking. These muscles atrophy in older adults and therefore this population, which is at high risk to falling, may benefit from strengthening these muscles in order to improve or retain their gait performance. Therefore, the aim was to provide insight in the evidence for the effect of interventions anticipated to improve PIFM strength on dynamic balance control and foot function during gait in adults. METHODS: A systematic literature search was performed in five electronic databases. The eligibility of peer-reviewed papers, published between January 1, 2010 and July 8, 2020, reporting controlled trials and pre-post interventional studies was assessed by two reviewers independently. Results from moderate- and high-quality studies were extracted for data synthesis by summarizing the standardized mean differences (SMD). The GRADE approach was used to assess the certainty of evidence. RESULTS: Screening of 9199 records resulted in the inclusion of 11 articles of which five were included for data synthesis. Included studies were mainly performed in younger populations. Low-certainty evidence revealed the beneficial effect of PIFM strengthening exercises on vertical ground reaction force (SMD: − 0.31-0.37). Very low-certainty evidence showed that PIFM strength training improved the performance on dynamic balance testing (SMD: 0.41–1.43). There was no evidence for the effect of PIFM strengthening exercises on medial longitudinal foot arch kinematics. CONCLUSIONS: This review revealed at best low-certainty evidence that PIFM strengthening exercises improve foot function during gait and very low-certainty evidence for its favorable effect on dynamic balance control. There is a need for high-quality studies that aim to investigate the effect of functional PIFM strengthening exercises in large samples of older adults. The outcome measures should be related to both fall risk and the role of the PIFMs such as propulsive forces and balance during locomotion in addition to PIFM strength measures. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13047-021-00509-0

    Advances in guava propagation.

    Get PDF
    Made available in DSpace on 2017-12-08T23:23:40Z (GMT). No. of bitstreams: 1 AlexMayerRBFGUAVAPropagation2017Incluido.pdf: 1009537 bytes, checksum: 1c2de381bab63888d67dea6baf90f3d4 (MD5) Previous issue date: 2017-12-08bitstream/item/168504/1/Alex-Mayer-RBF-GUAVA-Propagation-2017-Incluido.pd

    Metallo-Graphene Nanocomposite Electrocatalytic Platform for the Determination of Toxic Metal Ions

    Get PDF
    A Nafion-Graphene (Nafion-G) nanocomposite solution in combination with an in situ plated mercury film electrode was used as a highly sensitive electrochemical platform for the determination of Zn2+, Cd2+, Pb2+ and Cu2+ in 0.1 M acetate buffer (pH 4.6) by square-wave anodic stripping voltammetry (SWASV). Various operational parameters such as deposition potential, deposition time and electrode rotation speed were optimized. The Nafion-G nanocomposite sensing platform exhibited improved sensitivity for metal ion detection, in addition to well defined, reproducible and sharp stripping signals. The linear calibration curves ranged from 1 μg L−1 to 7 μg L−1 for individual analysis. The detection limits (3σ blank/slope) obtained were 0.07 μg L−1 for Pb2+, Zn2+ and Cu2+ and 0.08 μg L−1 for Cd2+ at a deposition time of 120 s. For practical applications recovery studies was done by spiking test samples with known concentrations and comparing the results with inductively coupled plasma mass spectrometry (ICP-MS) analyses. This was followed by real sample analysis
    • …
    corecore