716 research outputs found
On signalling over through-silicon via (TSV) interconnects in 3-D integrated circuits.
This paper discusses signal integrity (SI) issues and signalling techniques for Through Silicon Via (TSV) interconnects in 3-D Integrated Circuits (ICs). Field-solver extracted parasitics of TSVs have been employed in Spice simulations to investigate the effect of each parasitic component on performance metrics such as delay and crosstalk and identify a reduced-order electrical model that captures all relevant effects. We show that in dense TSV structures voltage-mode (VM) signalling does not lend itself to achieving high data-rates, and that current-mode (CM) signalling is more effective for high throughput signalling as well as jitter reduction. Data rates, energy consumption and coupled noise for the different signalling modes are extracted
Seasonal variation in the diurnal periodicity of activity of the perch, Perca fluviatilis L. [Translation from: Kalamies 1973(3) 3.]
The most common catch of the amateur angler is the perch and it is the diurnal periodicity of activity (& catchability) which is examined in this study based on earlier articles and manuscripts by the authors. Of all environmental factors, variation in light and temperature are the chief reasons in establishing the times of activity periods. Winter, summer and autumn activity was studied. The spawning perch was found to be more active than the non-spawning perch. The time of day in which the fish may be active is dependant on its ability to sense changes in the external environment. Its adaptation to light is the reason for day-activity in the winter, and also accounts for the fact that hardly any activity occurs between sunset and sunrise when this period exceeds 6 hours
Modification of the 4âŻMeV electron beam from a linear accelerator for irradiation of small superficial skin tumors
Uniform dose distribution with steep lateral gradient within depth range of 0â0.5 cm is crucial to be able to treat small skin lesions. The standard nominal 4 MeV electron beam from Elekta Versa HD linear accelerator was modified with degrading filter to remove the lateral scatter from treatment head and minimize the penumbra. The energy degrading method was verified based on dosimetric properties and output factors (OFs)with comparison of four types of measurement methods. The properties of degraded 4 MeV electron beam and developed electron applicators seem optimal for treating small targets near the skin surface. © 2019 The AuthorsNon peer reviewe
Estimation of breast height diameter and trunk curvature with linear and single-photon LiDARs
International audienceContext: Precision forestry together with new sensor technologies implies Digital Forest Inventories for estimation of volume and quality of trees in a stand.Aims: This study compared commercial LiDAR, new prototype SPAD LiDAR, and manual methods for measuring tree quality attributes, i.e., diameter at breast height (DBH) and trunk curvature in the forest stand.Methods: We measured 7 Scots pine trees (Pinus sylvestris) with commercial LiDAR (Zeb Horizon by GeoSLAM), prototype SPAD LiDAR, and manual devices. We compared manual measurements to the DBH and curvature values estimated based on LiDAR data. We also scanned a densely branched Picea abies to compare penetrability of the LiDARs and detectability of the obstructed trunk.Results: The DBH values deviated 1â3Â cm correlating to the specified accuracies of the employed devices, showing close to acceptable results. The curvature values deviated 1â6Â cm implying distorted range measurements from the top part of the trunks and inaccurate manual measurement method, leaving space for improvement. The most important finding was that the SPAD LiDAR outperformed conventional LiDAR in detecting tree stem of the densely branched spruce.Conclusion: These results represent preliminary but clear evidence that LiDAR technologies are already close to acceptable level in DBH measurements, but not yet satisfactory for curvature measurements. In addition, terrestrial SPAD LiDAR has a great potential to outperform conventional LiDARs in forest measurements of densely branched trees
Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi-center randomized controlled trial
Introduction
Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome.
Methods
A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study.
Results
The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34).
Conclusions
Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted
- âŠ