354 research outputs found

    Evaluation of methods of reducing community noise impact around San Jose municipal airport

    Get PDF
    A computer simulation of the airport noise impact on the surrounding communities was used to evaluate alternate operational procedures, improved technology, and land use conversion as methods of reducing community noise impact in the airport vicinity. In addition, a constant density population distribution was analyzed for possible application to other airport communities with fairly uniform population densities and similar aircraft operational patterns. The introduction of sound absorption material (SAM) was found to reduce community noise annoyance by over 25 percent, and the introduction of refan was found to reduce community annoyance by over 60 percent. Replacing the present aircraft was found to reduce the noise problem to very small proportions, and the introduction of an advanced technology twin was found to essentially eliminate the community noise problem

    Chromatic Information and Feature Detection in Fast Visual Analysis

    Get PDF
    The visual system is able to recognize a scene based on a sketch made of very simple features. This ability is likely crucial for survival, when fast image recognition is necessary, and it is believed that a primal sketch is extracted very early in the visual processing. Such highly simplified representations can be sufficient for accurate object discrimination, but an open question is the role played by color in this process. Rich color information is available in natural scenes, yet artist's sketches are usually monochromatic; and, black-and-white movies provide compelling representations of real world scenes. Also, the contrast sensitivity of color is low at fine spatial scales. We approach the question from the perspective of optimal information processing by a system endowed with limited computational resources. We show that when such limitations are taken into account, the intrinsic statistical properties of natural scenes imply that the most effective strategy is to ignore fine-scale color features and devote most of the bandwidth to gray-scale information. We find confirmation of these information-based predictions from psychophysics measurements of fast-viewing discrimination of natural scenes. We conclude that the lack of colored features in our visual representation, and our overall low sensitivity to high-frequency color components, are a consequence of an adaptation process, optimizing the size and power consumption of our brain for the visual world we live in

    Relating color discrimination to photopigment genes in deutan observers

    Get PDF
    AbstractDeutan observers are a heterogeneous group, varying nearly continuously from deuteranomalous trichromats with fine chromatic discrimination in the red/green range to deuteranopes who have none. We sought to relate chromatic discriminative ability among deutans measured psychophysically (phenotypes) to observers' separation between long-wave visual pigments inferred from visual pigment genes (genotypes). If middle-wave pigment genes are assumed not to be expressed in these deutan observers there is a clear relation between phenotype and genotype

    Pediatric Cerebral Palsy in Africa: Where Are We?

    Get PDF
    Cerebral palsy is the most common cause of physical disability in children worldwide. However, little is reported on this condition in the African context. Doctors from 22 countries in Africa, and representatives from a further 5 countries outside Africa, met to discuss the challenges in the evaluation and management of children with cerebral palsy in Africa and to propose service needs and further research. Basic care is limited by the poor availability of diagnostic facilities or medical personnel with experience and expertise in managing cerebral palsy, exacerbated by lack of available interventions such as medications, surgical procedures, or even regular therapy input. Relevant guidelines are lacking. In order to guide services for children with existing disabilities, to effectively target the main etiologies and to develop preventive strategies for the continent, research priorities must include multicenter collaborative studies looking at the prevalence, risk factors, and treatment of cerebral palsy

    Habitual wearers of colored lenses adapt more rapidly to the color changes the lenses produce

    Get PDF
    The visual system continuously adapts to the environment, allowing it to perform optimally in a changing visual world. One large change occurs every time one takes off or puts on a pair of spectacles. It would be advantageous for the visual system to learn to adapt particularly rapidly to such large, commonly occurring events, but whether it can do so remains unknown. Here, we tested whether people who routinely wear spectacles with colored lenses increase how rapidly they adapt to the color shifts their lenses produce. Adaptation to a global color shift causes the appearance of a test color to change. We measured changes in the color that appeared “unique yellow”, that is neither reddish nor greenish, as subjects donned and removed their spectacles. Nine habitual wearers and nine age-matched control subjects judged the color of a small monochromatic test light presented with a large, uniform, whitish surround every 5 s. Red lenses shifted unique yellow to more reddish colors (longer wavelengths), and greenish lenses shifted it to more greenish colors (shorter wavelengths), consistent with adaptation “normalizing” the appearance of the world. In controls, the time course of this adaptation contained a large, rapid component and a smaller gradual one, in agreement with prior results. Critically, in habitual wearers the rapid component was significantly larger, and the gradual component significantly smaller than in controls. The total amount of adaptation was also larger in habitual wearers than in controls. These data suggest strongly that the visual system adapts with increasing rapidity and strength as environments are encountered repeatedly over time. An additional unexpected finding was that baseline unique yellow shifted in a direction opposite to that produced by the habitually worn lenses. Overall, our results represent one of the first formal reports that adjusting to putting on or taking off spectacles becomes easier over time, and may have important implications for clinical management

    Practice Parameter: Diagnostic assessment of the child with cerebral palsy: Report of the Quality Standards Subcommittee of the American Academy of Neurology and the Practice Committee of the Child Neurology Society

    Get PDF
    OBJECTIVE: The Quality Standards Subcommittee of the American Academy of Neurology and the Practice Committee of the Child Neurology Society develop practice parameters as strategies for patient management based on analysis of evidence. For this parameter the authors reviewed available evidence on the assessment of a child suspected of having cerebral palsy (CP), a nonprogressive disorder of posture or movement due to a lesion of the developing brain. METHODS: Relevant literature was reviewed, abstracted, and classified. Recommendations were based on a four-tiered scheme of evidence classification. RESULTS: CP is a common problem, occurring in about 2 to 2.5 per 1,000 live births. In order to establish that a brain abnormality exists in children with CP that may, in turn, suggest an etiology and prognosis, neuroimaging is recommended with MRI preferred to CT (Level A). Metabolic and genetic studies should not be routinely obtained in the evaluation of the child with CP (Level B). If the clinical history or findings on neuroimaging do not determine a specific structural abnormality or if there are additional and atypical features in the history or clinical examination, metabolic and genetic testing should be considered (Level C). Detection of a brain malformation in a child with CP warrants consideration of an underlying genetic or metabolic etiology. Because the incidence of cerebral infarction is high in children with hemiplegic CP, diagnostic testing for coagulation disorders should be considered (Level B). However, there is insufficient evidence at present to be precise as to what studies should be ordered. An EEG is not recommended unless there are features suggestive of epilepsy or a specific epileptic syndrome (Level A). Because children with CP may have associated deficits of mental retardation, ophthalmologic and hearing impairments, speech and language disorders, and oral-motor dysfunction, screening for these conditions should be part of the initial assessment (Level A). CONCLUSIONS: Neuroimaging results in children with CP are commonly abnormal and may help determine the etiology. Screening for associated conditions is warranted as part of the initial evaluation

    Determining a healthy reference range and factors potentially influencing PRO-C3 – A biomarker of liver fibrosis

    Get PDF
    Background & AimsProgressive fibrosis has been identified as the major predictor of mortality in patients with non-alcoholic fatty liver disease (NAFLD). Several biomarkers are currently being evaluated for their ability to substitute the liver biopsy as the reference standard. Recent clinical studies in NAFLD/NASH patients support the utility of PRO-C3, a marker of type III collagen formation, as a marker for the degree of fibrosis, disease activity, and effect of treatment. Here we establish the healthy reference range, optimal sample handling conditions for both short- and long-term serum storage, and robustness for the PRO-C3 assay.MethodsPRO-C3 was measured in 269 healthy volunteers and in 222 NAFLD patients. Robustness of the PRO-C3 assay was measured according to Clinical and Laboratory Standards Institute standards and included validation of interference, precision, and reagent stability, whilst sample stability was defined for storage at different temperatures and for 3 freeze-thaw cycles. Fibrosis scoring was based on histological assessments and used as a reference for the diagnostic ability of PRO-C3 to discriminate between patients with different levels of fibrosis.ResultsRobustness of the PRO-C3 analysis validated by interference, precision, and reagent stability was found to be within the predefined acceptance criteria. The healthy reference range was determined to be 6.1–14.7 ng/ml. Levels of PRO-C3 were not affected by sex, age, BMI, or ethnicity. Levels of PRO-C3 were able to identify patients with clinically significant fibrosis and advanced fibrosis (AUC = 0.83 (95% CI [0.77–0.88], p <0.0001), and AUC = 0.79 (95% CI [0.73–0.85], p <0.0001), respectively).ConclusionsThe assay proved to be robust and sample stability was found to comply with hospital sample handling requirements. PRO-C3 measured in samples from patients with NAFLD/NASH was diagnostic for significant and advanced liver fibrosis
    corecore