703 research outputs found

    Simulation of High Power Factor Single Phase Inverter For PV Solar Array

    Full text link
    Photovoltaic (PV) systems are solar energy supplySystems which either supply power directly to an electrical equipment or feed energy into the public electricity grid. It focuses on the latest development of modelling and control of grid connected photovoltaic energy conversion system. In the photovoltaic system, power electronic conversion is necessary to improve the efficiency of PV panels and system stability. In these systems, the backstage power circuit consists of a high step-up DC to DC converter and a full-bridge inverter to convert DC to AC, as the grid voltage is AC in nature. Modelling of photovoltaic systems include modelling of SPV array, power electronics inverter/converter based on MATLAB/SIMULINK. This present control algorithm of a three-phase and single phase grid-connected photovoltaic (PV) system including the PV array and the electronic power conditioning (PCS) system, based on the MATLAB/Simulink software. It also discusses advances in MPP tracking technologies, the synchronization of the inverter and the connection to the grid

    International standards for early fetal size and pregnancy dating based on ultrasound measurement of crown-rump length in the first trimester of pregnancy.

    Get PDF
    OBJECTIVES: There are no international standards for relating fetal crown-rump length (CRL) to gestational age (GA), and most existing charts have considerable methodological limitations. The INTERGROWTH-21(st) Project aimed to produce the first international standards for early fetal size and ultrasound dating of pregnancy based on CRL measurement. METHODS: Urban areas in eight geographically diverse countries that met strict eligibility criteria were selected for the prospective, population-based recruitment, between 9 + 0 and 13 + 6 weeks' gestation, of healthy well-nourished women with singleton pregnancies at low risk of fetal growth impairment. GA was calculated on the basis of a certain last menstrual period, regular menstrual cycle and lack of hormonal medication or breastfeeding in the preceding 2 months. CRL was measured using strict protocols and quality-control measures. All women were followed up throughout pregnancy until delivery and hospital discharge. Cases of neonatal and fetal death, severe pregnancy complications and congenital abnormalities were excluded from the study. RESULTS: A total of 4607 women were enrolled in the Fetal Growth Longitudinal Study, one of the three main components of the INTERGROWTH-21(st) Project, of whom 4321 had a live singleton birth in the absence of severe maternal conditions or congenital abnormalities detected by ultrasound or at birth. The CRL was measured in 56 women at < 9 + 0 weeks' gestation; these were excluded, resulting in 4265 women who contributed data to the final analysis. The mean CRL and SD increased with GA almost linearly, and their relationship to GA is given by the following two equations (in which GA is in days and CRL in mm): mean CRL = -50.6562 + (0.815118 × GA) + (0.00535302 × GA(2) ); and SD of CRL = -2.21626 + (0.0984894 × GA). GA estimation is carried out according to the two equations: GA = 40.9041 + (3.21585 × CRL(0.5) ) + (0.348956 × CRL); and SD of GA = 2.39102 + (0.0193474 × CRL). CONCLUSIONS: We have produced international prescriptive standards for early fetal linear size and ultrasound dating of pregnancy in the first trimester that can be used throughout the world

    International standards for fetal brain structures based on serial ultrasound measurements from the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project.

    Get PDF
    OBJECTIVE: To create prescriptive growth standards for five fetal brain structures, measured by ultrasound, from healthy, well-nourished women, at low risk of impaired fetal growth and poor perinatal outcomes, taking part in the Fetal Growth Longitudinal Study (FGLS) of the INTERGROWTH-21st Project. METHODS: This was a complementary analysis of a large, population-based, multicentre, longitudinal study. We measured, in planes reconstructed from 3-dimensional (3D) ultrasound volumes of the fetal head at different time points in pregnancy, the size of the parieto-occipital fissure (POF), Sylvian fissure (SF), anterior horn of the lateral ventricle (AV), atrium of the posterior ventricle (PV) and cisterna magna (CM). The sample analysed was randomly selected from the overall FGLS population, ensuring an equal distribution amongst the eight diverse participating sites and of 3D ultrasound volumes across pregnancy (range: 15 - 36 weeks' gestation). Fractional polynomials were used to the construct standards. Growth and development of the infants were assessed at 1 and 2 years of age to confirm their adequacy for constructing international standards. RESULTS: From the entire FGLS cohort of 4321 women, 451 (10.4%) were randomly selected. After exclusions, 3D ultrasound volumes from 442 fetuses born without congenital malformations were used to create the charts. The fetal brain structures of interest were identified in 90% of cases. All structures showed increasing size with gestation and increasing variability for the POF, SF, PV and CM. The 3rd , 5th , 50th , 95th and 97th smoothed centile are presented. The 5th centile of POF and SF were 2.8 and 4.3 at 22 weeks and 4.2 and 9.4mm at 32 weeks respectively. The 95th centile of PV and CM were 8.5 and 7.4 at 22 weeks and 8.5 and 9.4mm at 32 weeks respectively. CONCLUSIONS: We have produced prescriptive size standards for fetal brain structures based on prospectively enrolled pregnancies at low risk of abnormal outcomes. We recommend these as international standards for the assessment of measurements obtained by ultrasound from fetal brain structures

    The objectives, design and implementation of the INTERGROWTH-21st Project

    Get PDF
    INTERGROWTH-21st is a multicentre, multiethnic, populationbased project, being conducted in eight geographical areas (Brazil, China, India, Italy, Kenya, Oman, UK and USA), with technical support from four global specialised units, to study growth, health and nutrition from early pregnancy to infancy. It aims to produce prescriptive growth standards, which conceptually extend the World Health Organization (WHO) Multicentre Growth Reference Study (MGRS) to cover fetal and newborn life. The new international standards will describe: (1) fetal growth assessed by clinical and ultrasound measures; (2) postnatal growth of term and preterm infants up to 2 years of age; and (3) the relationship between birthweight, length and head circumference, gestational age and perinatal outcomes. As the project has selected healthy cohorts with no obvious risk factors for intrauterine growth restriction, these standards will describe how all fetuses and newborns should grow, as opposed to traditional charts that describe how some have grown at a given place and time. These growth patterns will be related to morbidity and mortality to identify levels of perinatal risk. Additional aims include phenotypic characterisation of the preterm and impaired fetal growth syndromes and development of a prediction model, based on multiple ultrasound measurements, to estimate gestational age for use in pregnant women without access to early/frequent antenatal care

    International standards for fetal growth based on serial ultrasound measurements: the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project

    Get PDF
    Background: In 2006, WHO produced international growth standards for infants and children up to age 5 years on the basis of recommendations from a WHO expert committee. Using the same methods and conceptual approach, the Fetal Growth Longitudinal Study (FGLS), part of the INTERGROWTH-21st Project, aimed to develop international growth and size standards for fetuses. Methods: The multicentre, population-based FGLS assessed fetal growth in geographically defined urban populations in eight countries, in which most of the health and nutritional needs of mothers were met and adequate antenatal care was provided. We used ultrasound to take fetal anthropometric measurements prospectively from 14 weeks and 0 days of gestation until birth in a cohort of women with adequate health and nutritional status who were at low risk of intrauterine growth restriction. All women had a reliable estimate of gestational age confirmed by ultrasound measurement of fetal crown–rump length in the first trimester. The five primary ultrasound measures of fetal growth—head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length—were obtained every 5 weeks (within 1 week either side) from 14 weeks to 42 weeks of gestation. The best fitting curves for the five measures were selected using second-degree fractional polynomials and further modelled in a multilevel framework to account for the longitudinal design of the study. Findings: We screened 13 108 women commencing antenatal care at less than 14 weeks and 0 days of gestation, of whom 4607 (35%) were eligible. 4321 (94%) eligible women had pregnancies without major complications and delivered live singletons without congenital malformations (the analysis population). We documented very low maternal and perinatal mortality and morbidity, confirming that the participants were at low risk of adverse outcomes. For each of the five fetal growth measures, the mean differences between the observed and smoothed centiles for the 3rd, 50th, and 97th centiles, respectively, were small: 2·25 mm (SD 3·0), 0·02 mm (3·0), and −2·69 mm (3·2) for head circumference; 0·83 mm (0·9), −0·05 mm (0·8), and −0·84 mm (1·0) for biparietal diameter; 0·63 mm (1·2), 0·04 mm (1·1), and −1·05 mm (1·3) for occipitofrontal diameter; 2·99 mm (3·1), 0·25 mm (3·2), and −4·22 mm (3·7) for abdominal circumference; and 0·62 mm (0·8), 0·03 mm (0·8), and −0·65 mm (0·8) for femur length. We calculated the 3rd, 5th 10th, 50th, 90th, 95th and 97th centile curves according to gestational age for these ultrasound measures, representing the international standards for fetal growth. Interpretation: We recommend these international fetal growth standards for the clinical interpretation of routinely taken ultrasound measurements and for comparisons across populations. Funding: Bill & Melinda Gates Foundation

    Preparation and characterization of cotton fabrics with antimicrobial properties through the application of chitosan/silver-zeolite film

    Get PDF
    The development of antimicrobial cotton fabrics using chitosan/silver-zeolite film has been investigated in the present work. The film was applied to 100% cotton fabric using a common pad-dry-cure technique and citric acid was used as crosslinking agent. The resulting fabrics were characterized through infrared spectroscopy (FTIR), contact angle and scanning electron microscopy with X-ray microanalysis (SEM/EDS). The antimicrobial activity of the fabrics was assessed through the viable-cell counting method and the materials showed activity against S. aureus and T. rubrum. The textile performance of the fabrics was analysed regarding their characteristics of hydrophilicity and breathability. The finishing did not change the hydrophilic behaviour of the material. Although the permeability to air has reduced 20%, the permeability to water vapour remained practically unchanged. Therefore, the results suggested that the process approach of applying chitosan/silver-zeolite film is recommended to produce textiles with antibacterial properties.CNPq-Brazil (Conselho Nacional de Desenvolvimento Científico e Tecnológico – Brazil/National Council of Scientific and Technological Development – Brazil) for the doctoral scholarship (233550/2014-3). This work is also financed by FEDER funds through the Competitivity Factors Operational Programme – COMPETE and by national funds through FCT – Foundation for Science and Technology within the scope of the project POCI-01-0145-FEDER-007136. This research was partially supported by the Strategic Funding UID/Multi/04423/2013 through national funds provided by FCT - Foundation for Science and Technology and European Regional Development Fund (ERDF), in the framework of the program PT2020.info:eu-repo/semantics/publishedVersio

    International standards for symphysis-fundal height based on serial measurements from the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project: prospective cohort study in eight countries

    Get PDF
    Objective To create international symphysis-fundal height standards derived from pregnancies of healthy women with good maternal and perinatal outcomes. Design Prospective longitudinal observational study. Setting Eight geographically diverse urban regions in Brazil, China, India, Italy, Kenya, Oman, United Kingdom, and United States. Participants Healthy, well nourished pregnant women enrolled into the Fetal Growth Longitudinal Study component of the INTERGROWTH-21st Project at 9-14 weeks’ gestation, and followed up until birth. Main outcome measures Symphysis-fundal height was measured every five weeks from 14 weeks’ gestation until birth using standardised methods and dedicated research staff who were blinded to the symphysis-fundal height measurements by turning the tape measure so that numbers were not visible during examination. The best fitting curve was selected using second degree fractional polynomials and further modelled in a multilevel framework to account for the longitudinal design of the study. Results Of 13 108 women screened in the first trimester, 4607 (35.1%) met the study entry criteria. Of the eligible women, 4321 (93.8%) had pregnancies without major complications and delivered live singletons without congenital malformations. The median number of symphysis-fundal height measurements was 5.0 (range 1-7); 3976 (92.0%) women had four or more measurements. Symphysis-fundal height measurements increased almost linearly with gestational age; data were used to determine fitted 3rd, 50th, and 97th centile curves, which showed excellent agreement with observed values. Conclusions This study presents international standards to measure symphysis-fundal height as a first level screening tool for fetal growth disturbances

    Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review

    Get PDF
    Background: Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. Methods: We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. Results: The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Conclusion: Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation
    • …
    corecore