280 research outputs found

    Water Ice and Dust in the Innermost Coma of Comet 103P/Hartley 2

    Full text link
    On November 4th, 2010, the Deep Impact eXtended Investigation (DIXI) successfully encountered comet 103P/Hartley 2, when it was at a heliocentric distance of 1.06 AU. Spatially resolved near-IR spectra of comet Hartley 2 were acquired in the 1.05-4.83 micron wavelength range using the HRI-IR spectrometer. We present spectral maps of the inner ~10 kilometers of the coma collected 7 minutes and 23 minutes after closest approach. The extracted reflectance spectra include well-defined absorption bands near 1.5, 2.0, and 3.0 micron consistent in position, bandwidth, and shape with the presence of water ice grains. Using Hapke's radiative transfer model, we characterize the type of mixing (areal vs. intimate), relative abundance, grain size, and spatial distribution of water ice and refractories. Our modeling suggests that the dust, which dominates the innermost coma of Hartley 2 and is at a temperature of 300K, is thermally and physically decoupled from the fine-grained water ice particles, which are on the order of 1 micron in size. The strong correlation between the water ice, dust, and CO2 spatial distribution supports the concept that CO2 gas drags the water ice and dust grains from the nucleus. Once in the coma, the water ice begins subliming while the dust is in a constant outflow. The derived water ice scale-length is compatible with the lifetimes expected for 1-micron pure water ice grains at 1 AU, if velocities are near 0.5 m/s. Such velocities, about three order of magnitudes lower than the expansion velocities expected for isolated 1-micron water ice particles [Hanner, 1981; Whipple, 1951], suggest that the observed water ice grains are likely aggregates.Comment: 51 pages, 12 figures, accepted for publication in Icaru

    Patient-reported outcome (PRO) questionnaires for men who have radical surgery for prostate cancer: a conceptual review of existing instruments.

    Get PDF
    To critically review conceptual frameworks for available patient-reported outcome (PRO) questionnaires in men having radical prostatectomy (RP), psychometrically evaluate each questionnaire, and identify whether each is appropriate for use at the level of the individual patient. We searched PubMed, the Reports and Publications database of the University of Oxford Patient-Reported Outcomes Measurement Group and the website of the International Consortium for Health Outcomes Measurement (ICHOM) for psychometric reviews of prostate cancer-specific PRO questionnaires. From these we identified relevant questionnaires and critically appraised the conceptual content, guided by the Wilson and Cleary framework and psychometric properties, using well established criteria. The searches found four reviews and one recommendation paper. We identified seven prostate cancer-specific PROs: the Expanded Prostate Cancer Index Composite-26 (EPIC-26), Expanded Prostate Cancer Index Composite-50 (EPIC-50), University of California-Los Angeles Prostate Cancer Index (UCLA-PCI), Functional Assessment of Cancer Therapy - Prostate Cancer Subscale (FACT-P PCS), European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire - prostate specific 25-item (EORTC QLQ-PR25), Prostate Cancer - Quality of Life (PC-QoL), and Symptom Tracking and Reporting (STAR). Six out of seven measures purported to measure health-related quality of life (HRQL), but items focused strongly on urinary and sexual symptoms/functioning. The remaining questionnaire (STAR) claimed to assess functional recovery after RP. The psychometric evidence for these questionnaires was incomplete and variable in quality; none had evidence that they were appropriate for use with individual patients. Several questionnaires provide the basis of measures of urinary and/or sexual symptoms/functioning. Further work should explore other aspects of HRQL that are important for men having RP. Further psychometric work is also needed to determine whether they can be used at the individual level

    Planetary Spectrum Generator: an accurate online radiative transfer suite for atmospheres, comets, small bodies and exoplanets

    Full text link
    We have developed an online radiative-transfer suite (https://psg.gsfc.nasa.gov) applicable to a broad range of planetary objects (e.g., planets, moons, comets, asteroids, TNOs, KBOs, exoplanets). The Planetary Spectrum Generator (PSG) can synthesize planetary spectra (atmospheres and surfaces) for a broad range of wavelengths (UV/Vis/near-IR/IR/far-IR/THz/sub-mm/Radio) from any observatory (e.g., JWST, ALMA, Keck, SOFIA), any orbiter (e.g., ExoMars, Juno), or any lander (e.g., MSL). This is achieved by combining several state-of-the-art radiative transfer models, spectroscopic databases and planetary databases (i.e., climatological and orbital). PSG has a 3D (three-dimensional) orbital calculator for most bodies in the solar system, and all confirmed exoplanets, while the radiative-transfer models can ingest billions of spectral signatures for hundreds of species from several spectroscopic repositories. It integrates the latest radiative-transfer and scattering methods in order to compute high resolution spectra via line-by-line calculations, and utilizes the efficient correlated-k method at moderate resolutions, while for computing cometary spectra, PSG handles non-LTE and LTE excitation processes. PSG includes a realistic noise calculator that integrates several telescope / instrument configurations (e.g., interferometry, coronagraphs) and detector technologies (e.g., CCD, heterodyne detectors, bolometers). Such an integration of advanced spectroscopic methods into an online tool can greatly serve the planetary community, ultimately enabling the retrieval of planetary parameters from remote sensing data, efficient mission planning strategies, interpretation of current and future planetary data, calibration of spectroscopic data, and development of new instrument/spacecraft concepts.Comment: Journal of Quantitative Spectroscopy and Radiative Transfer, submitte

    "TNOs are Cool": A survey of the trans-Neptunian region VI. Herschel/PACS observations and thermal modeling of 19 classical Kuiper belt objects

    Full text link
    Trans-Neptunian objects (TNO) represent the leftovers of the formation of the Solar System. Their physical properties provide constraints to the models of formation and evolution of the various dynamical classes of objects in the outer Solar System. Based on a sample of 19 classical TNOs we determine radiometric sizes, geometric albedos and beaming parameters. Our sample is composed of both dynamically hot and cold classicals. We study the correlations of diameter and albedo of these two subsamples with each other and with orbital parameters, spectral slopes and colors. We have done three-band photometric observations with Herschel/PACS and we use a consistent method for data reduction and aperture photometry of this sample to obtain monochromatic flux densities at 70.0, 100.0 and 160.0 \mu m. Additionally, we use Spitzer/MIPS flux densities at 23.68 and 71.42 \mu m when available, and we present new Spitzer flux densities of eight targets. We derive diameters and albedos with the near-Earth asteroid thermal model (NEATM). As auxiliary data we use reexamined absolute visual magnitudes from the literature and data bases, part of which have been obtained by ground based programs in support of our Herschel key program. We have determined for the first time radiometric sizes and albedos of eight classical TNOs, and refined previous size and albedo estimates or limits of 11 other classicals. The new size estimates of 2002 MS4 and 120347 Salacia indicate that they are among the 10 largest TNOs known. Our new results confirm the recent findings that there are very diverse albedos among the classical TNOs and that cold classicals possess a high average albedo (0.17 +/- 0.04). Diameters of classical TNOs strongly correlate with orbital inclination in our sample. We also determine the bulk densities of six binary TNOs.Comment: 21 pages, 9 figures, accepted for publication in Astronomy and Astrophysic

    Uncorrelated Volatile Behavior during the 2011 Apparition of Comet C/2009 P1 Garradd

    Get PDF
    The High Resolution Instrument Infrared Spectrometer (HRI-IR) on board the Deep Impact Flyby spacecraft detected H2O, CO2, and CO in the coma of the dynamically young Oort Cloud comet C/2009 P1 (Garradd) post-perihelion at a heliocentric distance of 2 AU. Production rates were derived for the parent volatiles, Q_(H2O) = 4.6 ± 0.8 × 10^(28), Q_(CO2) = 3.9 ± 0.7 × 10^(27), and Q_(CO) = 2.9 ± 0.8 × 10^(28) molecules s^(–1), and are consistent with the trends seen by other observers and within the error bars of measurements acquired during a similar time period. When compiled with other observations of Garradd's dominant volatiles, unexpected behavior was seen in the release of CO. Garradd's H_2O outgassing, increasing and peaking pre-perihelion and then steadily decreasing, is more typical than that of CO, which monotonically increased throughout the entire apparition. Due to the temporal asymmetry in volatile release, Garradd exhibited the highest CO to H_2O abundance ratio ever observed for any comet inside the water snow line at ~60% during the HRI-IR observations. Also, the HRI-IR made the only direct measurement of CO_2, giving a typical cometary abundance ratio of CO_2 to H_2O of 8% but, with only one measurement, no sense of how it varied with orbital position

    Strain gauge properties of Pd+-ion-implanted polymer:

    Get PDF
    Pd+ ions (90 keV) were implanted at normal incidence and at room temperature in different highly insulating (>200 GΩ) thermoplastic polymers (poly(methyl methacrylate), polypropylene, polyethylene terephthalate glycol-modified, and polycarbonate). At high fluence and optimized process parameters, the ion implantation gives rise to the formation of a nanocomposite thin surface layer constituted by Pd nanoclusters and carbonaceous material (nanographite/amorphous carbon). The morphological, microstructural, and microanalytical properties of the nanocomposite layers were investigated by He-ion microscopy, glancing incidence X-ray diffraction, and Raman scattering, respectively. The electrical properties were characterized by resistance, van der Pauw, and Hall measurements. We performed accurate simultaneous deformation/bending experiments and electrical resistance measurements. We show that the electrical resistance varies linearly with the mechanical deformation (beam deflection) applied. The experimental results are interpreted by "hopping conductivity" model considering the nanostructure configuration of the nanocomposite layers. A gauge factor in the range between 4 and 8, depending on the ion-implanted polymer, was obtained for prototype strain gauge devices
    • …
    corecore