112 research outputs found

    Occurrence of Aspartame in Foodstuffs in Cyprus and Relevant Risk Assessment

    Get PDF
    The basic aim of the control is to keep the levels of additives in foodstuffs and their dietary intake at safety levels and to cover: (i) Basic and frequently consumed foodstuffs in high quantities with emphasis to the food consumed by children, (ii) the toxicologically most important and most frequently used additives e.g. azodyes and synthetic sweeteners, (iii) previously known non complying samples and the information from RASFF system of EU. Aspartame is a very hot issue because there is a variety of reduced energy or sugar free foodstuffs that people can consume

    Discovery of AZD3199, an inhaled ultralong acting β2 receptor agonist with rapid onset of action

    Get PDF
    A series of dibasic des-hydroxy β2 receptor agonists has been prepared and evaluated for potential as inhaled ultra-long acting bronchodilators. Determination of activities at the human β-adrenoreceptors demonstrated a series of highly potent and selective β2 receptor agonists that were progressed to further study in a guinea pig histamine-induced bronchoconstriction model. Following further assessment by; onset studies in guinea pig tracheal rings and human bronchial rings contracted with methacholine (guinea pigs) or carbachol (humans), duration of action studies in guinea pigs after intratracheal (i. t.) administration and further selectivity and safety profiling AZD3199 was shown to have an excellent over all profile and was progressed into clinical evaluation as a new ultra-long acting inhaled β2 receptor agonist with rapid onset of action

    Accuracy assessment of minimum control points for UAV photography and georeferencing

    No full text
    In recent years, Autonomous Unmanned Aerial Vehicles (AUAV) became popular among researchers across disciplines because they combine many advantages. One major application is monitoring and mapping. Their ability to fly beyond eye sight autonomously, collecting data over large areas whenever, wherever, makes them excellent platform for monitoring hazardous areas or disasters. In both cases rapid mapping is needed while human access isn't always a given. Indeed, current automatic processing of aerial photos using photogrammetry and computer vision algorithms allows for rapid orthophomap production and Digital Surface Model (DSM) generation, as tools for monitoring and damage assessment. In such cases, control point measurement using GPS is either impossible, or time consuming or costly. This work investigates accuracies that can be attained using few or none control points over areas of one square kilometer, in two test sites; a typical block and a corridor survey. On board GPS data logged during AUAV's flight are being used for direct georeferencing, while ground check points are being used for evaluation. In addition various control point layouts are being tested using bundle adjustment for accuracy evaluation. Results indicate that it is possible to use on board single frequency GPS for direct georeferencing in cases of disaster management or areas without easy access, or even over featureless areas. Due to large numbers of tie points in the bundle adjustment, horizontal accuracy can be fulfilled with a rather small number of control points, but vertical accuracy may not

    Accuracy assessment of minimum control points for UAV photography and georeferencing

    No full text
    In recent years, Autonomous Unmanned Aerial Vehicles (AUAV) became popular among researchers across disciplines because they combine many advantages. One major application is monitoring and mapping. Their ability to fly beyond eye sight autonomously, collecting data over large areas whenever, wherever, makes them excellent platform for monitoring hazardous areas or disasters. In both cases rapid mapping is needed while human access isn't always a given. Indeed, current automatic processing of aerial photos using photogrammetry and computer vision algorithms allows for rapid orthophomap production and Digital Surface Model (DSM) generation, as tools for monitoring and damage assessment. In such cases, control point measurement using GPS is either impossible, or time consuming or costly. This work investigates accuracies that can be attained using few or none control points over areas of one square kilometer, in two test sites; a typical block and a corridor survey. On board GPS data logged during AUAV's flight are being used for direct georeferencing, while ground check points are being used for evaluation. In addition various control point layouts are being tested using bundle adjustment for accuracy evaluation. Results indicate that it is possible to use on board single frequency GPS for direct georeferencing in cases of disaster management or areas without easy access, or even over featureless areas. Due to large numbers of tie points in the bundle adjustment, horizontal accuracy can be fulfilled with a rather small number of control points, but vertical accuracy may not

    Lead identification of benzimidazolone and azabenzimidazolone arylsulfonamides as CC-chemokine receptor 4 (CCR4) antagonists

    Get PDF
    A knowledge-based library of 2,3-dichlorophenylsulfonyl derivatives of commercially available aryl amines was synthesised and screened as human CCR4 antagonists, in order to identify a suitable hit for the start of a lead-optimisation programme. Hits were required to be more potent than an existing indazole series, have better physicochemical properties (c log P 116 μg/mL), and be stable to acid and light. The benzimidazol-2-one core was identified as a hit suitable for further investigation. Substitution at N1 with small alkyl groups was tolerated; however, these analogues were inactive in the whole blood assay (pA2 <5). Azabenzimidazolone analogues were all found to be active, with compound 38 exhibiting whole blood activity of 6.1, low molecular weight (389) and chrom log D7.4 (2.4), high LE (0.43), and solubility (152 μg/mL). In addition, 38 had human serum albumin binding of around 93% and met all the criteria for progression to lead optimisation

    Evaluation of an enzyme immunoassay for plasma-free metanephrines in the diagnosis of catecholamine-secreting tumors (vol 161, pg 131, 2009)

    No full text
    OBJECTIVE: To define the test characteristics of an enzyme immunoassay (EIA) for plasma-free metanephrines (metanephrine and normetanephrine) in the diagnosis of pheochromocytoma and paraganglioma. DESIGN: Prospective observational design from a single University Hospital. Twenty-four hour urine for catecholamines and plasma for free metanephrines were collected from patients with a clinical suspicion of pheochromocytoma or paraganglioma. Patient records were reviewed for clinical data, follow-up, imaging and laboratory results to establish or exclude the diagnosis of pheochromocytoma. PATIENTS AND METHODS: Out of 178 consecutive patients, 10 had a paraganglioma and 12 had a pheochromocytoma: 156 were finally judged not to harbour active tumors and were therefore considered as controls. The main outcome measure was the diagnosis or exclusion of paraganglioma or pheochromocytoma and test characteristics of plasma-free metanephrines measured by EIA. RESULTS: Urinary epinephrine had a sensitivity of 45.5% and norepinephrine a sensitivity of 75% (98.8% specificity) for the diagnosis of pheochromocytoma. Plasma-free metanephrine and normetanephrine both had a sensitivity of 66.7% and a specificity of 100%, but when combined (either positive) they demonstrated a 91.7% sensitivity with a preserved specificity of 100%. For the diagnosis of paraganglioma, urinary norepinephrine gave slightly better results than plasma-free metanephrines, but combined testing was of no additional value. CONCLUSIONS: Plasma-free metanephrines measured by EIA have better diagnostic test characteristics than urinary catecholamines in the diagnosis of pheochromocytoma. The EIA offers a simple and effective measurement of plasma-free metanephrines
    corecore