61 research outputs found

    Consensus-Based Technical Recommendations for Clinical Translation of Renal Phase Contrast MRI

    Get PDF
    BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4–10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60–74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE:

    Interference of partial visual analysis of root filling quality and apical status on retreatment decisions

    Get PDF
    OBJECTIVE: The presence of periapical radiolucency has been used as a criterion for endodontic treatment failure. However, in addition to the inherent limitations of radiographic examinations, radiographic interpretations are extremely subjective. Thus, this study investigated the effect of partial analysis of root filling quality and periapical status on retreatment decisions by general dentists. MATERIAL AND METHODS: Twelve digitalized periapical radiographs were analyzed by 10 observers. The study was conducted at three time points at 1-week intervals. Radiographs edited with the Adobe Photoshop CS4 software were analyzed at three time points: first, only root filling quality was analyzed; second, only the periapical areas of the teeth under study were visualized; finally, observers analyzed the unedited radiographic image. Spearman's coefficient was used to analyze the correlations between the scores assigned when the periapical area was not visible and when the unedited radiograph was analyzed, as well as between the scores assigned when root fillings where not visible and when the unedited radiograph was analyzed. Sensitivity, specificity, positive and negative predictive values between partial images and unedited radiographs were also used to analyze retreatment decisions. The level of significance was set at 5%. RESULTS: The visualization of the root filling on the unedited radiograph affected the interpretation of the periapical status and the technical quality of the fillings has a greater influence on the general dentist's decision to prescribe endodontic retreatment than the periapical condition. CONCLUSION: In order to make endodontic diagnosis, radiographic interpretation process should not only emphasize technical aspects, but also consider biological factors

    Ethnic differences in dissatisfaction with sexual life in patients with type 2 diabetes in a Swedish town

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The first aim of this study was to analyze whether self-reported satisfaction with one's sexual life was associated with ethnicity (Swedish and Assyrian/Syrian) in patients with type 2 diabetes. The second was to study whether the association between satisfaction with one's sexual life and ethnicity remained after controlling for possible confounders such as marital status, HbA1c, medication, and presence of other diseases.</p> <p>Methods</p> <p>This cross-sectional, questionnaire-based study was conducted at four primary health care centers in the Swedish town of Södertälje. A total of 354 persons (173 ethnic Assyrians/Syrians and 181 ethnic Swedes) participated.</p> <p>Results</p> <p>The total prevalence of self-reported dissatisfaction with one's sexual life in both groups was 49%. No significant ethnic differences were found in the outcome. In the final model, regardless of ethnicity, the odds ratio (OR) for self-reported dissatisfaction with one's sexual life in those ≥ 70 years old was 2.52 (95% CI 1.33-4.80). Among those living alone or with children, the OR was more than three times higher than for married or cohabiting individuals (OR = 3.10, 95% CI 1.60-6.00). Those with other diseases had an OR 1.89 times (95% CI 1.10-3.40) higher than those without other diseases.</p> <p>Conclusions</p> <p>The findings demonstrate that almost half of participants were dissatisfied with their sexual life and highlight the importance of sexual life to people with type 2 diabetes. This factor should not be ignored in clinical evaluations. Moreover, the findings demonstrate that it is possible to include questions on sexual life in investigations of patients with type 2 diabetes and even in other health-related, questionnaire studies, despite the sensitivity of the issue of sexuality.</p

    A survey of failed post-retained restorations

    Get PDF
    Survival of endodontically treated, post-restored teeth depends on a multitude of factors, all of which are practically impossible to include in a randomized, controlled clinical study. The purpose of this survey was to characterize and analyze reported failures of post-retained restorations to identify factors critical to failure and to type of failure. A questionnaire was mailed to private practitioners in Denmark with a request to complete the questionnaire whenever a patient presented with a failed post-retained restoration. Information was gathered on factors related to the patient, the tooth, the restorative materials, and the techniques. Two-hundred and sixty questionnaires were collected from 171 practitioners over a 3-year period. Functioning time until failure varied between 3 months and 38 years. Mean survival time until failure was 11 years. Of the failed restorations, 61% had functioned for 10 years or less. Fracture of the tooth was the most common type of failure reported, followed by loosening of the post and fracture of the post. Tapered posts implied an increased risk of tooth fracture compared to loosening or fracture of the post, and the relative risk of tooth fracture increased with the functioning time until failure. Fracture of the post was more common among male than female patients. On the basis of this survey of failed post-retained restorations, it was concluded that tapered posts were associated with a higher risk of tooth fracture than were parallel-sided posts

    Consensus‐based technical recommendations for clinical translation of renal phase contrast MRI

    Get PDF
    Background Phase‐contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC‐MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC‐MRI as a clinically useful tool. Purpose To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC‐MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. Study Type Systematic consensus process using a modified Delphi method. Population Not applicable. Sequence Field/Strength Renal fast gradient echo‐based 2D PC‐MRI. Assessment An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4–10) years of experience in 2D PC‐MRI formulated consensus statements on renal 2D PC‐MRI in two rounds of surveys. Starting from a recently published systematic review article, literature‐based and data‐driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. Statistical Tests Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60–74% agreement among the experts. Results Among 60 statements, 57 (95%) achieved consensus after the second‐round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC‐MRI data acquisition, processing, and reporting. Data Conclusion These recommendations might promote a widespread adoption of renal PC‐MRI, and may help foster the set‐up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC‐MRI. Level of Evidence 1 Technical Efficacy Stage

    Consensus-based technical recommendations for clinical translation of renal phase contrast MRI

    Get PDF
    Background Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool.Purpose To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies.Study Type Systematic consensus process using a modified Delphi method.Population Not applicable.Sequence Field/Strength Renal fast gradient echo-based 2D PC-MRI.Assessment An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated.Statistical Tests Consensus was defined as >= 75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts.Results Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting.Data Conclusion These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI.Level of Evidence 1Technical Efficacy Stage 1Cardiovascular Aspects of Radiolog
    corecore