642 research outputs found

    First narrow-band search for continuous gravitational waves from known pulsars in advanced detector data

    Get PDF
    Spinning neutron stars asymmetric with respect to their rotation axis are potential sources of continuous gravitational waves for ground-based interferometric detectors. In the case of known pulsars a fully coherent search, based on matched filtering, which uses the position and rotational parameters obtained from electromagnetic observations, can be carried out. Matched filtering maximizes the signalto- noise (SNR) ratio, but a large sensitivity loss is expected in case of even a very small mismatch between the assumed and the true signal parameters. For this reason, narrow-band analysis methods have been developed, allowing a fully coherent search for gravitational waves from known pulsars over a fraction of a hertz and several spin-down values. In this paper we describe a narrow-band search of 11 pulsars using data from Advanced LIGO’s first observing run. Although we have found several initial outliers, further studies show no significant evidence for the presence of a gravitational wave signal. Finally, we have placed upper limits on the signal strain amplitude lower than the spin-down limit for 5 of the 11 targets over the bands searched; in the case of J1813-1749 the spin-down limit has been beaten for the first time. For an additional 3 targets, the median upper limit across the search bands is below the spin-down limit. This is the most sensitive narrow-band search for continuous gravitational waves carried out so far

    Identification and mitigation of narrow spectral artifacts that degrade searches for persistent gravitational waves in the first two observing runs of Advanced LIGO

    Get PDF
    Searches are under way in Advanced LIGO and Virgo data for persistent gravitational waves from continuous sources, e.g. rapidly rotating galactic neutron stars, and stochastic sources, e.g. relic gravitational waves from the Big Bang or superposition of distant astrophysical events such as mergers of black holes or neutron stars. These searches can be degraded by the presence of narrow spectral artifacts (lines) due to instrumental or environmental disturbances. We describe a variety of methods used for finding, identifying and mitigating these artifacts, illustrated with particular examples. Results are provided in the form of lists of line artifacts that can safely be treated as non-astrophysical. Such lists are used to improve the efficiencies and sensitivities of continuous and stochastic gravitational wave searches by allowing vetoes of false outliers and permitting data cleaning

    Ethnic dissimilarity predicts belonging motive frustration and reduced organizational attachment

    Get PDF
    Some empirical studies show negative consequences of being demographically different from one’s group, but the underlying psychological mechanisms are not well understood. To address this gap, we investigated the role of the belonging and distinctiveness motives in individuals’ experiences of being ethnically dissimilar from their group. We propose that ethnic dissimilarity satisfies group members’ need for distinctiveness whereas it frustrates members’ need for belonging, and this frustration reduces their organizational attachment. An experimental study showed that ethnic dissimilarity led to heightened arousal of the belonging motive, indicating that this motive was frustrated. In a naturalistic study of real-life student groups, ethnic dissimilarity was associated with frustrated belonging, which in turn was associated with reduced organizational attachment. This paper contributes to the literature on demographic dissimilarity in groups by closely examining the effect of demographic dissimilarity on group members’ fundamental motives and reactions to group membership

    Rest and Dobutamine stress echocardiography in the evaluation of mid-term results of mitral valve repair in Barlow's disease

    Get PDF
    BACKGROUND: Surgical "anatomical" repair is the most frequent technique used to correct mitral regurgitation due to severe myxomatous valve disease. Debate, however, persists on the efficacy of this technique, as well as on the durability of the repaired valve, and on its functioning and hemodynamics under stress conditions. Thus, a basal and Dobutamine echocardiographic (DSE) study was carried out to evaluate these parameters at mid-term follow-up. METHODS AND RESULTS: Twenty patients selected for the study (12 men and 8 women, mean age 60 ± 9 years) underwent pre- and post-operative transthoracic echocardiography (TTE) and intra-operative transesophageal echocardiography (TEE). At mid-term follow-up (20 ± 5 months) all patients underwent rest TTE and DSE (3 min. dose increments up to 40 microg/Kg/min protocol). Pre-discharge and one-month TTE showed absence of MR in 11 pts., trivial or mild MR in 9 pts. and normal mitral valve area and gradients. Mid-term TTE showed decrease in left atrial and ventricular dimension, in pulmonary artery pressure (sPAP) and grade of MR. During DSE a significant increase in mitral valve area, maximum and mean gradients, sPAP, heart rate and cardiac output and a decrease in systolic annular diameter and left ventricular volume were found; in 6 pts. a transient left ventricular outflow tract obstruction was observed. CONCLUSION: Basal and Dobutamine stress echocardiography proved to be valuable tools for evaluation of mid-term results of mitral valve repair. In our study population, the surgical technique employed had a favourable impact on several cardiac parameters, evaluated by these methods

    Somatic mutations of KIT in familial testicular germ cell tumours

    Get PDF
    Somatic mutations of the KIT gene have been reported in mast cell diseases and gastrointestinal stromal tumours. Recently, they have also been found in mediastinal and testicular germ cell tumours (TGCTs), particularly in cases with bilateral disease. We screened the KIT coding sequence (except exon 1) for germline mutations in 240 pedigrees with two or more cases of TGCT. No germline mutations were found. Exons 10, 11 and 17 of KIT were examined for somatic mutations in 123 TGCT from 93 multiple-case testicular cancer families. Five somatic mutations were identified; four were missense amino acid substitutions in exon 17 and one was a 12bp in-frame deletion in exon 11. Two of seven TGCT from cases with bilateral disease carried KIT mutations compared with 3 out 116 unilateral cases (p = 0.026). The results indicate that somatic KIT mutations are implicated in the development of a minority of familial as well as sporadic TGCT. They also lend support to the hypothesis that KIT mutations primarily take place during embryogenesis such that primordial germ cells with KIT mutations are distributed to both testes

    Relationship between mitral leaflets angles, left ventricular geometry and mitral deformation indices in patients with ischemic mitral regurgitation: imaging by echocardiography and cardiac magnetic resonance

    Get PDF
    Chronic ischemic mitral regurgitation (IMR) is associated with a markedly worse prognosis after myocardial infarction (MI).The study aimed to evaluate the relationship between anterior and posterior mitral leaflet angle (MLA) values, left ventricle remodeling and severity of ischaemic mitral regurgitation (IMR). Methods: Forty-two patients (age 63.5 ± 9.7 years, 36 men) with chronic IMR (regurgitant volume, RV > 20 ml; >6 months after MI) underwent transthoracic echocardiography (TTE) and cardiovascular magnetic resonance (CMR) imaging. Anterior and posterior MLA, determined by echocardiography, were correlated with indices of LV remodeling, mitral apparatus deformation and IMR severity by CMR. The anterior and posterior MLA was 25.41 ± 4.28 and 38.37 ± 8.89° (mean ± SD). In 5 patients (11.9%) the posterior MLA was ≥45°. There was a significant correlation between anterior MLA and RV (r = 0.74, P = 0.01). For patients with RV > 30 ml this correlation was stronger (r = 0.97, P = 0.005) and, in addition, there was a correlation between the RV and posterior MLA (r = 0.90, P = 0.037), between tenting area and posterior MLA (r = 0.90, P = 0.04), and between tenting area and anterior MLA (r = 0.82, P = 0.08). With regard to LV remodeling parameters, there was weaker but significant correlation between posterior MLA and LV end-diastolic volume index (r = 0.35, P = 0.031), LV end-systolic volume index (r = 0.37, P = 0.021), stroke volume (r = 0.35, P = 0.03), sphericity index (r = 0.33, P = 0.041). Anterior MLA correlated with wall motion score index (r = 0.41, P = 0.019). Besides, there was a correlation between posterior MLA and left atrial volume (r = 0.41, P = 0.012). Measurement of anterior and posterior MLA may play an important role in evaluating patients with IMR

    A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials.</p> <p>Methods/Design</p> <p>The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1), single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express<sup>2 </sup>paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to <2.75 mm that compares TAXUS Element with a matched historical bare metal Express stent control.</p> <p>Discussion</p> <p>The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at <url>http://www.clinicaltrials.gov</url>, identification numbers NCT00484315 and NCT00489541.</p
    corecore