    Elimination of Herpes Simplex Virus-2 and Epstein-Barr Virus With Seraph 100 Microbind Affinity Blood Filter and Therapeutic Plasma Exchange: An Explorative Study in a Patient With Acute Liver Failure

    Full text link
    OBJECTIVES Herpes simplex virus (HSV)-2 is a rare cause of hepatitis that can lead to acute liver failure (ALF) and often death. The earlier the initiation of acyclovir treatment the better the survival. With regard to ALF, controlled randomized data support the use of therapeutic plasma exchange (TPE) both as bridge to recovery or transplantation-possibly by modulating the systemic inflammatory response and by replacing coagulation factors. Seraph 100 Microbind Affinity Blood Filter (Seraph; Ex Thera Medical, Martinez, CA), a novel extracorporeal adsorption device, removes living pathogens by binding to a heparin-coated surface was shown to efficiently clear HSV-2 particles in vitro. Here, we tested the combination of Seraph with TPE to reduce a massive HSV-2 viral load to reach a situation in that liver transplantation would be feasible. DESIGN Explorative study. SETTING Academic tertiary care transplant center. PATIENT Single patient with HSV-2-induced ALF. INTERVENTIONS TPE + Seraph 100 Microbind Affinity Blood Filter. MEASUREMENTS AND MAIN RESULTS We report Seraph clearance data of HSV-2 and of Epstein-Barr virus (EBV) in vivo as well as total viral elimination by TPE. Genome copies/mL of HSV-2 and EBV in EDTA plasma were measured by polymerase chain reaction every 60 minutes over 6 hours after starting Seraph both systemically and post adsorber. Also, HSV-2 and EBV were quantified before and after TPE and in the removed apheresis plasma. We found a total elimination of 1.81 × e11^{11} HSV-2 copies and 2.11 × e6^{6} EBV copies with a single TPE (exchange volume of 5L; 1.5× calculated plasma volume). Whole blood clearance of HSV-2 in the first 6 hours of treatment was 6.64 mL/min (4.98-12.92 mL/min). Despite much lower baseline viremia, clearance of EBV was higher 36.62 mL/min (22.67-53.48 mL/min). CONCLUSIONS TPE was able to remove circulating HSV-2 copies by 25% and EBV copies by 40% from the blood. On the other hand, clearance of HSV-2 by Seraph was clinically irrelevant, but Seraph seemed to be far more effective of removing EBV, implicating a possible use in EBV-associated pathologies, but this requires further study

    Outcomes of patients with acute respiratory failure on veno-venous extracorporeal membrane oxygenation requiring additional circulatory support by veno-venoarterial extracorporeal membrane oxygenation

    Full text link
    ObjectiveVeno-venous (V-V) extracorporeal membrane oxygenation (ECMO) is increasingly used to support patients with severe acute respiratory distress syndrome (ARDS). In case of additional cardio-circulatory failure, some experienced centers upgrade the V-V ECMO with an additional arterial return cannula (termed V-VA ECMO). Here we analyzed short- and long-term outcome together with potential predictors of mortality.DesignMulticenter, retrospective analysis between January 2008 and September 2021.SettingThree tertiary care ECMO centers in Germany (Hannover, Bonn) and Switzerland (Zurich).PatientsSeventy-three V-V ECMO patients with ARDS and additional acute cardio-circulatory deterioration required an upgrade to V-VA ECMO were included in this study.Measurements and main resultsFifty-three patients required an upgrade from V-V to V-VA and 20 patients were directly triple cannulated. Median (Interquartile Range) age was 49 (28–57) years and SOFA score was 14 (12–17) at V-VA ECMO upgrade. Vasoactive-inotropic score decreased from 53 (12–123) at V-VA ECMO upgrade to 9 (3–37) after 24 h of V-VA ECMO support. Weaning from V-VA and V-V ECMO was successful in 47 (64%) and 40 (55%) patients, respectively. Duration of ECMO support was 12 (6–22) days and ICU length of stay was 32 (16–46) days. Overall ICU mortality was 48% and hospital mortality 51%. Two additional patients died after hospital discharge while the remaining patients survived up to two years (with six patients being lost to follow-up). The vast majority of patients was free from higher degree persistent organ dysfunction at follow-up. A SOFA score > 14 and higher lactate concentrations at the day of V-VA upgrade were independent predictors of mortality in the multivariate regression analysis.ConclusionIn this analysis, the use of V-VA ECMO in patients with ARDS and concomitant cardiocirculatory failure was associated with a hospital survival of about 50%, and most of these patients survived up to 2 years. A SOFA score > 14 and elevated lactate levels at the day of V-VA upgrade predict unfavorable outcome

    Carboxyhemoglobin predicts oxygenator performance and imminent oxygenator change in extracorporeal membrane oxygenation

    Get PDF
    Background The continuous exposure of blood to a non-biological surface during extracorporeal membrane oxygenation (ECMO) may lead to progressive thrombus formation in the oxygenator, hemolysis and consequently impaired gas exchange. In most centers oxygenator performance is monitored only on a once daily basis. Carboxyhemoglobin (COHb) is generated upon red cell lysis and is routinely measured with any co-oximetry performed to surveille gas exchange and acid–base homeostasis every couple of hours. This retrospective cohort study aims to evaluate COHb in the arterial blood gas as a novel marker of oxygenator dysfunction and its predictive value for imminent oxygenator change. Results Out of the 484 screened patients on ECMO 89, cumulatively requiring 116 oxygenator changes within 1833 patient days, including 19,692 arterial COHb measurements were analyzed. Higher COHb levels were associated with lower post-oxygenator pO2_{2} (estimate for log(COHb): − 2.176 [95% CI − 2.927, − 1.427], p < 0.0001) and with a shorter time to oxygenator change (estimate for log(COHb): − 67.895 [95% CI − 74.209, − 61.542] hours, p < 0.0001). COHb was predictive of oxygenator change within 6 h (estimate for log(COHb): 5.027 [95% CI 1.670, 15.126], p = 0.004). Conclusion COHb correlates with oxygenator performance and can be predictive of imminent oxygenator change. Therefore, longitudinal measurements of COHb in clinical routine might be a cheap and more granular candidate for ECMO surveillance that should be further analyzed in a controlled prospective trial design

    Standardized Assessment of Automatic Segmentation of White Matter Hyperintensities and Results of the WMH Segmentation Challenge

    Get PDF
    Quantification of cerebral white matter hyperintensities (WMH) of presumed vascular origin is of key importance in many neurological research studies. Currently, measurements are often still obtained from manual segmentations on brain MR images, which is a laborious procedure. The automatic WMH segmentation methods exist, but a standardized comparison of the performance of such methods is lacking. We organized a scientific challenge, in which developers could evaluate their methods on a standardized multi-center/-scanner image dataset, giving an objective comparison: the WMH Segmentation Challenge. Sixty T1 + FLAIR images from three MR scanners were released with the manual WMH segmentations for training. A test set of 110 images from five MR scanners was used for evaluation. The segmentation methods had to be containerized and submitted to the challenge organizers. Five evaluation metrics were used to rank the methods: 1) Dice similarity coefficient; 2) modified Hausdorff distance (95th percentile); 3) absolute log-transformed volume difference; 4) sensitivity for detecting individual lesions; and 5) F1-score for individual lesions. In addition, the methods were ranked on their inter-scanner robustness; 20 participants submitted their methods for evaluation. This paper provides a detailed analysis of the results. In brief, there is a cluster of four methods that rank significantly better than the other methods, with one clear winner. The inter-scanner robustness ranking shows that not all the methods generalize to unseen scanners. The challenge remains open for future submissions and provides a public platform for method evaluation

    Standardized Assessment of Automatic Segmentation of White Matter Hyperintensities; Results of the WMH Segmentation Challenge

    Get PDF
    Quantification of cerebral white matter hyperintensities (WMH) of presumed vascular origin is of key importance in many neurological research studies. Currently, measurements are often still obtained from manual segmentations on brain MR images, which is a laborious procedure. Automatic WMH segmentation methods exist, but a standardized comparison of the performance of such methods is lacking. We organized a scientific challenge, in which developers could evaluate their method on a standardized multi-center/-scanner image dataset, giving an objective comparison: the WMH Segmentation Challenge (https://wmh.isi.uu.nl/). Sixty T1+FLAIR images from three MR scanners were released with manual WMH segmentations for training. A test set of 110 images from five MR scanners was used for evaluation. Segmentation methods had to be containerized and submitted to the challenge organizers. Five evaluation metrics were used to rank the methods: (1) Dice similarity coefficient, (2) modified Hausdorff distance (95th percentile), (3) absolute log-transformed volume difference, (4) sensitivity for detecting individual lesions, and (5) F1-score for individual lesions. Additionally, methods were ranked on their inter-scanner robustness. Twenty participants submitted their method for evaluation. This paper provides a detailed analysis of the results. In brief, there is a cluster of four methods that rank significantly better than the other methods, with one clear winner. The inter-scanner robustness ranking shows that not all methods generalize to unseen scanners. The challenge remains open for future submissions and provides a public platform for method evaluation

    Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep

    Full text link
    BACKGROUND: Locking plates are widely used in fracture fixation, mainly for meta-diaphyseal fractures, comminuted fractures, fractures with a critical-size bone defect, periprosthetic fractures, osteotomies, and fractures in osteoporotic bone. The aim of this animal study was to evaluate the effect on bone-healing of dynamization of locking plate constructs by means of new 5.0-mm dynamic locking screws (in the DLS group), which allow near-cortex micromotion, compared with a more rigid construct utilizing standard bicortical locking-head screws (in the LS group). Use of dynamic locking screws allows modulation of the stiffness of existing locking compression plate systems via parallel interfragmentary micromotion. METHODS: A standardized diaphyseal tibial osteotomy (90°, 3-mm fracture gap) was performed and stabilized with a six-hole large-fragment locking compression plate in twelve female sheep (six in each group). Radiographs were made postoperatively and then weekly from week three until sacrifice at nine weeks. Macroscopic, biomechanical, histologic, and radiographic assessments and microcomputed tomography were performed. RESULTS: The callus in the tested specimens in the DLS group had better biomechanical stability, with a significantly greater maximum failure moment (mean and standard deviation [SD] as a percentage of intact, 55.15 ± 20.65 compared with 26.80 ± 14.96 in the LS group; p = 0.021). The DLS group also had greater periosteal callus volume at the near cortex (mean volume and SD as a percentage of the tibial shaft volume, 36.21% ± 10.08% compared with 18.98% ± 8.61% in the LS group; p = 0.026) and in the intercortical region (mean volume and SD as a percentage of the bone volume of the tibial shaft, 3.56% ± 0.52% compared with 2.64% ± 0.98% in the LS group; p = 0.045), as shown by microcomputed tomography. The DLS group also had significantly greater torsional stiffness (mean and SD as a percentage of intact, 84.88 ± 13.51 compared with 58.89 ± 20.61 in the LS group; p = 0.027). CONCLUSIONS: Controlled micromotion and nearly homogeneous interfragmentary strain at the fracture site, together with the stable bicortical fixation achieved by the new dynamic locking screw, led to more uniform callus formation, significantly more callus formation at the near cortex, and biomechanically more competent bone-healing compared with use of rigid locking plate constructs with locking-head screws

    Metabolic disturbances potentially attributable to clogging during continuous renal replacement therapy

    Get PDF
    Background Clogging is characterized by a progressive impairment of transmembrane patency in renal replacement devices and occurs due to obstruction of pores by unknown molecules. If citrate-based anti-coagulation is used, clogging can manifest as a metabolic alkalosis accompanied by hypernatremia and hypercalcemia, primarily a consequence of Na3_{3}Citrate infusion. An increased incidence of clogging has been observed during the COVID-19 pandemic. However, precise factors contributing to the formation remain uncertain. This investigation aimed to analyze its incidence and assessed time-varying trajectories of associated factors in critically ill patients on continuous renal replacement therapy (CRRT). Methods In this retrospective, single-center data analysis, we evaluated COVID-19 patients undergoing CRRT and admitted to critical care between March 2020 and December 2021. We assessed the proportional incidence of clogging surrogates in the overall population and subgroups based on the specific CRRT devices employed at our institution, including multiFiltrate (Fresenius Medical Care) and Prismaflex System (Baxter). Moderate and severe clogging were defined as Na > 145 or ≥ 150 mmol/l and HCO3_{3}^{−} > 28.0 or ≥ 30 mmol/l, respectively, with a total albumin-corrected calcium > 2.54 mmol/l. A mixed effect model was introduced to investigate factors associated with development of clogging. Results Fifty-three patients with 240 CRRT runs were analyzed. Moderate and severe clogging occurred in 15% (8/53) and 19% (10/53) of patients, respectively. Twenty-seven percent (37/136) of CRRTs conducted with a multiFiltrate device met the criteria for clogging, whereas no clogging could be observed in patients dialyzed with the Prismaflex System. Occurrence of clogging was associated with elevated triglyceride plasma levels at filter start (p = 0.013), amount of enteral nutrition (p = 0.002) and an increasing white blood cell count over time (p = 0.002). Conclusions Clogging seems to be a frequently observed phenomenon in critically ill COVID-19 patients. The presence of hypertriglyceridemia, combined with systemic inflammation, may facilitate the development of an impermeable secondary membrane within filters, thereby contributing to compromised membrane patency