149 research outputs found
Acute Strenuous Exercise Induces an Imbalance on Histone H4 Acetylation/Histone Deacetylase 2 and Increases the Proinflammatory Profile of PBMC of Obese Individuals
This study evaluated the response of global histone H4 acetylation (H4ac), histone deacetylase 2 (HDAC2) activity, as well as the production of proinflammatory cytokines and monocyte phenotypes of lean and obese males after exercise. Ten lean and ten obese sedentary men were submitted to one session of strenuous exercise, and peripheral blood mononuclear cells (PBMC) were stimulated in vitro with lipopolysaccharide (LPS). Global H4ac levels, HDAC2 activity in PBMC, and IL-6, IL-8, and TNF-α production were analyzed. Monocyte phenotype was determined in accordance with the expression of CD14 and CD16. At rest, obese individuals presented higher frequency of proinflammatory CD14+CD16+ monocytes. LPS induced a significant augment in global H4ac and in the production of IL-6, IL-8, and TNF-α mainly in obese individuals. After exercise, the increased production of IL-8 and TNF-α and peripheral frequency of CD14+CD16+ were observed in both groups. In addition, exercise also induced a significant hyperacetylation of histone H4 and decreased HDAC2 activity in both nonstimulated and LPS-stimulated PBMC of obese individuals. Our data indicate that the obesity impacts on H4ac levels and that strenuous exercise leads to an enhanced chronic low-grade inflammation profile in obesity via an imbalance on H4ac/HDAC2
The BLue Amazon Brain (BLAB): A Modular Architecture of Services about the Brazilian Maritime Territory
We describe the first steps in the development of an artificial agent focused
on the Brazilian maritime territory, a large region within the South Atlantic
also known as the Blue Amazon. The "BLue Amazon Brain" (BLAB) integrates a
number of services aimed at disseminating information about this region and its
importance, functioning as a tool for environmental awareness. The main service
provided by BLAB is a conversational facility that deals with complex questions
about the Blue Amazon, called BLAB-Chat; its central component is a controller
that manages several task-oriented natural language processing modules (e.g.,
question answering and summarizer systems). These modules have access to an
internal data lake as well as to third-party databases. A news reporter
(BLAB-Reporter) and a purposely-developed wiki (BLAB-Wiki) are also part of the
BLAB service architecture. In this paper, we describe our current version of
BLAB's architecture (interface, backend, web services, NLP modules, and
resources) and comment on the challenges we have faced so far, such as the lack
of training data and the scattered state of domain information. Solving these
issues presents a considerable challenge in the development of artificial
intelligence for technical domains
Oxidative Stress Correlates with Headache Symptoms in Fibromyalgia: Coenzyme Q10 Effect on Clinical Improvement
This is an open-access article distributed under the terms of the Creative Commons Attribution License.[Background]: Fibromyalgia (FM) is a chronic pain syndrome with unknown etiology and a wide spectrum of symptoms such as allodynia, debilitating fatigue, joint stiffness and migraine. Recent studies have shown some evidences demonstrating that oxidative stress is associated to clinical symptoms in FM of fibromyalgia. We examined oxidative stress and bioenergetic status in blood mononuclear cells (BMCs) and its association to headache symptoms in FM patients. The effects of oral coenzyme Q 10 (CoQ 10) supplementation on biochemical markers and clinical improvement were also evaluated. [Methods]: We studied 20 FM patients and 15 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ), visual analogues scales (VAS), and the Headache Impact Test (HIT-6). Oxidative stress was determined by measuring CoQ 10, catalase and lipid peroxidation (LPO) levels in BMCs. Bioenergetic status was assessed by measuring ATP levels in BMCs. [Results]: We found decreased CoQ 10, catalase and ATP levels in BMCs from FM patients as compared to normal control (P<0.05 and P<0.001, respectively) We also found increased level of LPO in BMCs from FM patients as compared to normal control (P<0.001). Significant negative correlations between CoQ 10 or catalase levels in BMCs and headache parameters were observed (r = -0.59, P<0.05; r = -0.68, P<0.05, respectively). Furthermore, LPO levels showed a significant positive correlation with HIT-6 (r = 0.33, P<.05). Oral CoQ 10 supplementation restored biochemical parameters and induced a significant improvement in clinical and headache symptoms (P<0.001). [Discussion]: The results of this study suggest a role for mitochondrial dysfunction and oxidative stress in the headache symptoms associated with FM. CoQ10 supplementation should be examined in a larger placebo controlled trial as a possible treatment in FM.This work has been supported by IV Plan Propio de Investigación (University of Seville, ref. 2010/00000453), FIS PI10/00543 grant, FIS EC08/00076 grant, Ministerio de Sanidad, Spain and Fondo Europeo de Desarrollo Regional (FEDER-Unión Europea), SAS 111242 grant, Servicio Andaluz de Salud-Junta de Andalucía, Proyecto de Investigación de Excelencia de la Junta de Andalucía CTS-5725 and Federación Andaluza de Fibromialgia y Fatiga Crónica (ALBA Andalucía).Peer Reviewe
Genomics and epidemiology for gastric adenocarcinomas (GE4GAC): a Brazilian initiative to study gastric cancer
Abstract Gastric cancer (GC) is the fifth most common type of cancer worldwide with high incidences in Asia, Central, and South American countries. This patchy distribution means that GC studies are neglected by large research centers from developed countries. The need for further understanding of this complex disease, including the local importance of epidemiological factors and the rich ancestral admixture found in Brazil, stimulated the implementation of the GE4GAC project. GE4GAC aims to embrace epidemiological, clinical, molecular and microbiological data from Brazilian controls and patients with malignant and pre-malignant gastric disease. In this letter, we summarize the main goals of the project, including subject and sample accrual and current findings
Low-energy Calibration of XENON1T with an Internal Ar Source
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenontime projection chamber, with an internal Ar source was performed. Thiscalibration source features a 35-day half-life and provides two mono-energeticlines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keVare measured to be (32.30.3) photons/keV and (40.60.5) electrons/keV,respectively, in agreement with other measurements and with NEST predictions.The electron yield at 0.27 keV is also measured and it is(68.0) electrons/keV. The Ar calibration confirms thatthe detector is well-understood in the energy region close to the detectionthreshold, with the 2.82 keV line reconstructed at (2.830.02) keV, whichfurther validates the model used to interpret the low-energy electronic recoilexcess previously reported by XENON1T. The ability to efficiently remove argonwith cryogenic distillation after the calibration proves that Ar can beconsidered as a regular calibration source for multi-tonne xenon detectors.<br
Solar neutrino detection sensitivity in DARWIN via electron scattering
We detail the sensitivity of the proposed liquid xenon DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: pp, 7Be, 13N, 15O and pep. The precision of the 13N, 15O and pep components is hindered by the double-beta decay of 136Xe and, thus, would benefit from a depleted target. A high-statistics observation of pp neutrinos would allow us to infer the values of the electroweak mixing angle, sin 2θw, and the electron-type neutrino survival probability, Pee, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, with 10 live years of data and a 30 tonne fiducial volume. An observation of pp and 7Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high- (GS98) and low-metallicity (AGS09) solar models with 2.1–2.5σ significance, independent of external measurements from other experiments or a measurement of 8B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of 131Xe
Low-energy calibration of XENON1T with an internal Ar source
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal 37Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3±0.3) photons/keV and (40.6±0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0+6.3−3.7) electrons/keV. The 37Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83±0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that 37Ar can be considered as a regular calibration source for multi-tonne xenon detectors
The Triggerless Data Acquisition System of the XENONnT Experiment
The XENONnT detector uses the latest and largest liquid xenon-based timeprojection chamber (TPC) operated by the XENON Collaboration, aimed atdetecting Weakly Interacting Massive Particles and conducting other rare eventsearches. The XENONnT data acquisition (DAQ) system constitutes an upgraded andexpanded version of the XENON1T DAQ system. For its operation, it reliespredominantly on commercially available hardware accompanied by open-source andcustom-developed software. The three constituent subsystems of the XENONnTdetector, the TPC (main detector), muon veto, and the newly introduced neutronveto, are integrated into a single DAQ, and can be operated both independentlyand as a unified system. In total, the DAQ digitizes the signals of 698photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPCare digitized twice, at and gain. The DAQ for the mostpart is a triggerless system, reading out and storing every signal that exceedsthe digitization thresholds. Custom-developed software is used to process theacquired data, making it available within for live data quality monitoring and online analyses. The entire system withall the three subsystems was successfully commissioned and has been operatingcontinuously, comfortably withstanding readout rates that exceed MB/sduring calibration. Livetime during normal operation exceeds and is during most high-rate calibrations. The combined DAQ system hascollected more than 2 PB of both calibration and science data during thecommissioning of XENONnT and the first science run.<br
Low-energy Calibration of XENON1T with an Internal Ar Source
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon
time projection chamber, with an internal Ar source was performed. This
calibration source features a 35-day half-life and provides two mono-energetic
lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV
are measured to be (32.30.3) photons/keV and (40.60.5) electrons/keV,
respectively, in agreement with other measurements and with NEST predictions.
The electron yield at 0.27 keV is also measured and it is
(68.0) electrons/keV. The Ar calibration confirms that
the detector is well-understood in the energy region close to the detection
threshold, with the 2.82 keV line reconstructed at (2.830.02) keV, which
further validates the model used to interpret the low-energy electronic recoil
excess previously reported by XENON1T. The ability to efficiently remove argon
with cryogenic distillation after the calibration proves that Ar can be
considered as a regular calibration source for multi-tonne xenon detectors
- …