    Image Derived Input Functions: Effects of Motion on Tracer Kinetic Analyses

    Get PDF
    Purpose: To quantify the effects of motion affected image-derived input functions (IDIF) on the outcome of tracer kinetic analyses. Procedures: Two simulation studies, one based on high and the other on low cortical uptake, were performed. Different degrees of rotational and axial translational motion were added to the final frames of simulated dynamic positron emission tomography scans. Extracted IDIFs from motion affected simulated scans were compared to original IDIFs and to outcome of tracer kinetic analysis (volume of distribution, V T). Results: Differences in IDIF values of up to 239 % were found for the last frames. Patient motion of more than 6 ° or 5 mm resulted in at least 10 % higher or lower VT values for the high cortical tracer. Conclusion: The degrees of motion studied are commonly observed in clinical studies and hamper the extraction of accurate IDIFs. Therefore, it is essential to ensure that patient motion is minimal and corrected for

    Bone Metabolism after Total Hip Revision Surgery with Impacted Grafting: Evaluation using H215O and [18F]fluoride PET; A Pilot Study

    Get PDF
    Purpose: To evaluate bone blood flow and bone formation in patients after total hip revision surgery with impacted bone grafting using H2 15O and [18F]fluoride positron emission tomography (PET). Procedures: To asses bone blood flow and bone metabolism in bone allograft after impaction grafting, four patients treated with total hip revision surgery were enrolled prospectively in this study. Six patients scheduled for primary hip arthroplasties were included as a control group. The study protocol consisted of three H2 15O and [18F]fluoride PET scans in each patient. Results: Bone blood flow increased significantly compared to the preoperative state in patients treated for primary hip arthroplasty. In patients undergoing revision surgery, bone blood flow was twofold to threefold higher compared to the preoperative state, but did not reach significance. Bone metabolism in patients undergoing revision was threefold higher 2 weeks postoperatively compared to the primary hip group. We found a significant correlation between Ki and bone blood flow. Conclusions: Allogeneic bone grafts induce a higher rate of local periprosthetic bone formation compared to periprosthetic bone formation after a primary total hip placement. In vivo coupling between bone blood flow and bone metabolism suggests that bone metabolism in allogeneic bone grafts may partly rely on bone blood flow adaptations

    Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner

    Get PDF
    PURPOSE: Parametric imaging of absolute myocardial blood flow (MBF) using [(15)O]H(2)O enables determination of MBF with high spatial resolution. The aim of this study was to develop a method for generating reproducible, high-quality and quantitative parametric MBF images with minimal user intervention. METHODS: Nineteen patients referred for evaluation of MBF underwent rest and adenosine stress [(15)O]H(2)O positron emission tomography (PET) scans. Ascending aorta and right ventricular (RV) cavity volumes of interest (VOIs) were used as input functions. Implementation of a basis function method (BFM) of the single-tissue model with an additional correction for RV spillover was used to generate parametric images. The average segmental MBF derived from parametric images was compared with MBF obtained using nonlinear least-squares regression (NLR) of VOI data. Four segmentation algorithms were evaluated for automatic extraction of input functions. Segmental MBF obtained using these input functions was compared with MBF obtained using manually defined input functions. RESULTS: The average parametric MBF showed a high agreement with NLR-derived MBF [intraclass correlation coefficient (ICC) = 0.984]. For each segmentation algorithm there was at least one implementation that yielded high agreement (ICC > 0.9) with manually obtained input functions, although MBF calculated using each algorithm was at least 10% higher. Cluster analysis with six clusters yielded the highest agreement (ICC = 0.977), together with good segmentation reproducibility (coefficient of variation of MBF <5%). CONCLUSION: Parametric MBF images of diagnostic quality can be generated automatically using cluster analysis and a implementation of a BFM of the single-tissue model with additional RV spillover correction. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00259-011-1730-3) contains supplementary material, which is available to authorized users

    Lessons on Tumour Response: Imaging during Therapy with 177Lu-DOTA-octreotate. A Case Report on a Patient with a Large Volume of Poorly Differentiated Neuroendocrine Carcinoma

    Get PDF
    Favourable outcomes of peptide receptor radiotherapy (PRRT) of neuroendocrine tumours have been reported during the last years. Still, there are uncertainties on the radionuclides to be used, the treatment planning, and the indication in patients with a high proliferation rate

    Image-derived input functions from dynamic O-15-water PET scans using penalised reconstruction

    Get PDF
    BACKGROUND: Quantitative positron emission tomography (PET) scans of the brain typically require arterial blood sampling but this is complicated and logistically challenging. One solution to remove the need for arterial blood sampling is the use of image-derived input functions (IDIFs). Obtaining accurate IDIFs, however, has proved to be challenging, mainly due to the limited resolution of PET. Here, we employ penalised reconstruction alongside iterative thresholding methods and simple partial volume correction methods to produce IDIFs from a single PET scan, and subsequently, compare these to blood-sampled input curves (BSIFs) as ground truth. Retrospectively we used data from sixteen subjects with two dynamic 15O-labelled water PET scans and continuous arterial blood sampling: one baseline scan and another post-administration of acetazolamide. RESULTS: IDIFs and BSIFs agreed well in terms of the area under the curve of input curves when comparing peaks, tails and peak-to-tail ratios with R2 values of 0.95, 0.70 and 0.76, respectively. Grey matter cerebral blood flow (CBF) values showed good agreement with an average difference between the BSIF and IDIF CBF values of 2% ± and a coefficient of variation (CoV) of 7.3%. CONCLUSION: Our results show promising results that a robust IDIF can be produced for dynamic 15O–water PET scans using only the dynamic PET scan images with no need for a corresponding MRI or complex analytical techniques and thereby making routine clinical use of quantitative CBF measurements with 15O–water feasible

    Partial volume correction of brain PET studies using iterative deconvolution in combination with HYPR denoising

    Get PDF
    Background: Accurate quantification of PET studies depends on the spatial resolution of the PET data. The commonly limited PET resolution results in partial volume effects (PVE). Iterative deconvolution methods (IDM) have been proposed as a means to correct for PVE. IDM improves spatial resolution of PET studies without the need for structural information (e.g. MR scans). On the other hand, deconvolution also increases noise, which results in lower signal-to-noise ratios (SNR). The aim of this study was to implement IDM in combination with HighlY constrained back-PRojection (HYPR) denoising to mitigate poor SNR properties of conventional IDM.Methods: An anthropomorphic Hoffman brain phantom was filled with an [F-18]FDG solution of similar to 25 kBq mL(-1) and scanned for 30 min on a Philips Ingenuity TF PET/CT scanner (Philips, Cleveland, USA) using a dynamic brain protocol with various frame durations ranging from 10 to 300 s. Van Cittert IDM was used for PVC of the scans. In addition, HYPR was used to improve SNR of the dynamic PET images, applying it both before and/or after IDM. The Hoffman phantom dataset was used to optimise IDM parameters (number of iterations, type of algorithm, with/without HYPR) and the order of HYPR implementation based on the best average agreement of measured and actual activity concentrations in the regions. Next, dynamic [C-11]flumazenil (five healthy subjects) and [C-11]PIB (four healthy subjects and four patients with Alzheimer's disease) scans were used to assess the impact of IDM with and without HYPR on plasma input-derived distribution volumes (V-T) across various regions of the brain.Results: In the case of [C-11]flumazenil scans, Hypr-IDM-Hypr showed an increase of 5 to 20% in the regional V-T whereas a 0 to 10% increase or decrease was seen in the case of [C-11]PIB depending on the volume of interest or type of subject (healthy or patient). References for these comparisons were the V(T)s from the PVE-uncorrected scans.Conclusions: IDM improved quantitative accuracy of measured activity concentrations. Moreover, the use of IDM in combination with HYPR (Hypr-IDM-Hypr) was able to correct for PVE without increasing noise.</p

    Quantitative imaging of 124I and 86Y with PET

    Get PDF
    The quantitative accuracy and image quality of positron emission tomography (PET) measurements with 124I and 86Y is affected by the prompt emission of gamma radiation and positrons in their decays, as well as the higher energy of the emitted positrons compared to those emitted by 18F. PET scanners cannot distinguish between true coincidences, involving two 511-keV annihilation photons, and coincidences involving one annihilation photon and a prompt gamma, if the energy of this prompt gamma is within the energy window of the scanner. The current review deals with a number of aspects of the challenge this poses for quantitative PET imaging. First, the effect of prompt gamma coincidences on quantitative accuracy of PET images is discussed and a number of suggested corrections are described. Then, the effect of prompt gamma coincidences and the increased singles count rates due to gamma radiation on the count rate performance of PET is addressed, as well as possible improvements based on modification of the scanner’s energy windows. Finally, the effect of positron energy on spatial resolution and recovery is assessed. The methods presented in this overview aim to overcome the challenges associated with the decay characteristics of 124I and 86Y. Careful application of the presented correction methods can allow for quantitatively accurate images with improved image contrast