6,212 research outputs found

    The Ring Imaging Cherenkov detector (RICH) of the AMS experiment

    Full text link
    The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and velocity of the charged cosmic particles. A RICH prototype consisting of 96 photomultiplier units, including a piece of the conical reflector, was built and its performance evaluated with ion beam data. Preliminary results of the in-beam tests performed with ion fragments resulting from collisions of a 158 GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported. The collected data included tests to the final front-end electronics and to different aerogel radiators. Cherenkov rings for a large range of charged nuclei and with reflected photons were observed. The data analysis confirms the design goals. Charge separation up to Fe and velocity resolution of the order of 0.1% for singly charged particles are obtained.Comment: 29th International Conference on Cosmic Rays (Pune, India

    Minimax Current Density Coil Design

    Full text link
    'Coil design' is an inverse problem in which arrangements of wire are designed to generate a prescribed magnetic field when energized with electric current. The design of gradient and shim coils for magnetic resonance imaging (MRI) are important examples of coil design. The magnetic fields that these coils generate are usually required to be both strong and accurate. Other electromagnetic properties of the coils, such as inductance, may be considered in the design process, which becomes an optimization problem. The maximum current density is additionally optimized in this work and the resultant coils are investigated for performance and practicality. Coils with minimax current density were found to exhibit maximally spread wires and may help disperse localized regions of Joule heating. They also produce the highest possible magnetic field strength per unit current for any given surface and wire size. Three different flavours of boundary element method that employ different basis functions (triangular elements with uniform current, cylindrical elements with sinusoidal current and conic section elements with sinusoidal-uniform current) were used with this approach to illustrate its generality.Comment: 24 pages, 6 figures, 2 tables. To appear in Journal of Physics D: Applied Physic

    The AMS-RICH velocity and charge reconstruction

    Full text link
    The AMS detector, to be installed on the International Space Station, includes a Ring Imaging Cerenkov detector with two different radiators, silica aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to provide very precise measurements of velocity and electric charge in a wide range of cosmic nuclei energies and atomic numbers. The detector geometry, in particular the presence of a reflector for acceptance purposes, leads to complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The results of different reconstruction methods applied to test beam data as well as to simulated samples are presented. To ensure nominal performances throughout the flight, several detector parameters have to be carefully monitored. The algorithms developed to fulfill these requirements are presented. The velocity and charge measurements provided by the RICH detector endow the AMS spectrometer with precise particle identification capabilities in a wide energy range. The expected performances on light isotope separation are discussed.Comment: Contribution to the ICRC07, Merida, Mexico (2007); Presenter: F. Bara

    The r'-band luminosity function of Abell1367: a comparison with Coma

    Get PDF
    We made a large (approximately 1degr x 1degr) r'-band imaging survey of the central regions of the two nearby clusters of galaxies, Abell1367 and Coma. The data, presented as a catalog, are used to construct the r'-band luminosity function (LF) of galaxies in these two clusters, by subtracting the Yasuda et al. (2001) galaxy counts from our cluster counts. Our Coma luminosity function is consistent with previous determinations, i.e. providing a faint end slope alpha = -1.47_-0.09^+0.08, significantly steeper than the one we find for Abell1367 (alpha = -1.07_-0.16^+0.20). The counts in Abell1367 show a relative minimum at r' ~ 19, followed by a steep increase faintward. The difference between the two clusters appears significant, given the consistency of the experimental conditions in the two clusters. Whereas for Coma we find a significant increase of the slope of the LF outwards, no such effect is found for Abell1367.Comment: 12 pages, 8 figures, accepted for publication in A&

    The RICH detector of the AMS-02 experiment: status and physics prospects

    Full text link
    The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and with high energy photon detection capability up to a few hundred GeV. It is equipped with several subsystems, one of which is a proximity focusing RICH detector with a dual radiator (aerogel+NaF) that provides reliable measurements for particle velocity and charge. The assembly and testing of the AMS RICH is currently being finished and the full AMS detector is expected to be ready by the end of 2008. The RICH detector of AMS-02 is presented. Physics prospects are briefly discussed.Comment: 5 pages. Contribution to the 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications (Como 2007). Presenter: Rui Pereir

    Addressing the high cervical cancer rates along the Texas-Mexico border through community outreach, patient navigation, and provider training/telementoring

    Get PDF
    Objective: Cervical cancer incidence and mortality rates are 68% and 57% higher, respectively, along the Texas-Mexico border compared with the rest of the United States. This is likely due to a combination of low health literacy, limited access to affordable screening, and a lack of trained personnel to perform colposcopy, loop electrosurgical excision procedures (LEEP), and appropriate management of women with pre-invasive disease. The objective of our study was to increase cervical cancer screening, diagnosis, and treatment rates in the Rio Grande Valley (RGV). Method: We initiated a comprehensive program at two health centers and one mobile clinic in the RGV consisting of (1) a public education program designed for community health workers to teach women about cervical cancer screening and HPV vaccination coupled with patient navigation to participating clinics; (2) colposcopy and LEEP training for physicians and advanced-practice providers through locally held hands-on courses and mentoring program; and (3) implementation of Project ECHO (Extension for Community Health Outcomes), a well-established telementoring program using video conferencing to connect academic specialists with community providers for case-based learning. We compared screening, diagnosis, and treatment rates pre- and post-program implementation. Results: From November 2014 to June 2018, local providers screened 19,028 women with Pap ± HPV testing (baseline 12,460, 53% increase); performed colposcopy on 2,644 women with abnormal screening results (baseline 945, 180% increase); and performed 483 LEEP procedures for treatment of cervical dysplasia (baseline 0). Ten women were diagnosed with invasive cancer and navigated to one of the participating gynecologic oncologists for treatment (baseline N/A). Five additional providers in the RGV completed the mentoring program to be certified to perform colposcopy (100% increase from baseline of 5) and two additional providers to perform LEEP (baseline 0). ECHO telementoring video conferences have been held every two weeks for a total 94 sessions (average of 22 participants/session) with 182 patient cases presented and discussed. Conclusion: Our comprehensive approach has led to an increase in the number of women undergoing cervical cancer screening and diagnosis/treatment of dysplasia. If sustained, we anticipate these efforts will decrease cervical cancer rates in the RGV. The program is currently being expanded to additional medically underserved regions of Texas

    Sex differences in mortality in patients with COPD

    Get PDF
    Little is known about survival and clinical prognostic factors in females with chronic obstructive pulmonary disease (COPD). The aim of the present study was to determine the survival difference between males and females with COPD and to compare the value of the different prognostic factors for the disease. In total, 265 females and 272 males with COPD matched at baseline by BODE (body mass index, airflow obstruction, dyspnoea, exercise capacity) and American Thoracic Society/European Respiratory Society/Global Initiative of Chronic Obstructive Lung Disease criteria were prospectively followed. Demographics, lung function, St George’s Respiratory Questionnaire, BODE index, the components of the BODE index and comorbidity were determined. Survival was documented and sex differences were determined using Kaplan–Meier analysis. The strength of the association of the studied variables with mortality was determined using multivariate and receiver operating curves analysis. All-cause (40 versus 18%) and respiratory mortality (24 versus 10%) were higher in males than females. Multivariate analysis identified the BODE index in females and the BODE index and Charlson comorbidity score in males as the best predictors of mortality. The area under the curve of the BODE index was a better predictor of mortality than the forced expiratory volume in one second for both sexes. At similar chronic obstructive pulmonary disease severity by BODE index and forced expiratory volume in one second, females have significantly better survival than males. For both sexes the BODE index is a better predictor of survival than the forced expiratory volume in one second

    Determination of ππ\pi\pi scattering lengths from measurement of π+π−\pi^+\pi^- atom lifetime

    Get PDF
    The DIRAC experiment at CERN has achieved a sizeable production of π+π−\pi^+\pi^- atoms and has significantly improved the precision on its lifetime determination. From a sample of 21227 atomic pairs, a 4% measurement of the S-wave ππ\pi\pi scattering length difference ∣a0−a2∣=(.0.2533−0.0078+0.0080∣stat.−0.0073+0.0078∣syst)Mπ+−1|a_0-a_2| = (.0.2533^{+0.0080}_{-0.0078}|_\mathrm{stat}.{}^{+0.0078}_{-0.0073}|_\mathrm{syst})M_{\pi^+}^{-1} has been attained, providing an important test of Chiral Perturbation Theory.Comment: 6 pages, 6 figure
    • …
    corecore