24 research outputs found

    PB.23: Effect of detector type on cancer detection in digital mammography

    Get PDF
    This work measured the effect that image quality associated with different detectors has on cancer detection in mammography using a novel method for changing the appearance of images.\ud \ud A set of 270 mammography cases (one view, both breasts) was acquired using five Hologic Selenias and two Hologic Dimensions X-ray units: 80 normal, 80 with simulated inserted subtle calcification clusters, 80 with subtle real noncalcification malignant lesions and 30 with benign lesions (biopsy proven). These 270 cases (Arm 1) were converted to appear as if they had been acquired on two other imaging systems: needle image plate computed radiography (CR) (Arm 2) and powder phosphor CR (Arm 3). Three experienced mammography readers marked the location of suspected cancers in the images and classified whether each lesion would require further investigation and the confidence in that decision. Performance was calculated as the area under curve (AUC) of the alternative free-response receiver operating characteristic curv

    Global Kidney Exchange: Analysis and Background Papers from the Perspective of the Right to Health

    Get PDF
    Global Kidney Exchange (GKE) is a program aimed at facilitating trans-national kidney donation. Although its proponents aim at reducing the unmet demand of kidneys in the United States through the trans-nationalization of kidney exchange programs, the World Health Organization (WHO) and The Transplantation Society (TTS) have expressed concerns about its potential effect on black markets of organs and transnational organ trafficking, as well as on low- or middle-income countries health systems. For GKE to be implemented, it would need to be permitted to operate in at least some low- or middle-income countries. What are the right to health implications of GKE’s implementation? With the aim of answering this question, the eighteen University of Denver students in the First Year Seminar course I taught in autumn 2017 with the title “The Right to Health in Theory and Practice”, identified and researched the different aspects that would affect this issue, and produced the analysis we present in this report. Based on our analysis, the potential right to health implications of GKE are: First, the program may improve timely access to organ donation primarily to patients with health insurance in the United States. Second, a large-scale implementation of the program may have a positive impact on health costs savings, which potentially could benefit the United States health system. Third, on a global health level, the program relies on existing health inequalities among countries in terms of funding, human resources, and health system strengthening, and it is likely to exacerbate those inequalities. Fourth, the program has the potential of negatively affecting the efforts that low- and middle-income countries are already doing to address end-stage renal failure, including the improvement of their own organ donation systems. Finally, given what we have learned about the current situation of organ trafficking, it is easy to think that GKE would unintentionally end up being linked to chains of organ trade. The only way how a program like GKE could have a positive impact from a right to health perspective is if it establishes local partnerships that have the effect of decreasing health inequalities. Additionally, we identified some issues of concern that are beyond the level of influence of local authorities: the unmet demand of kidneys in high-income countries is a reality that incentivizes organ trade and transplant tourism, and this is a problem in need of solutions; transnational organ trafficking as well as human trafficking with the purpose of organ donation are problems that need more visibility; for a global exchange of organs to be implemented, it would need to rely on supranational or transnational regulation and oversight; and the global epidemic of chronic kidney disease needs to be addressed through a public health perspective that emphasizes prevention

    Abundance of the Quorum-Sensing Factor Ax21 in Four Strains of Stenotrophomonas maltophilia Correlates with Mortality Rate in a New Zebrafish Model of Infection

    Get PDF
    Stenotrophomonas maltophilia is a Gram-negative pathogen with emerging nosocomial incidence. Little is known about its pathogenesis and the genomic diversity exhibited by clinical isolates complicates the study of pathogenicity and virulence factors. Here, we present a strategy to identify such factors in new clinical isolates of S. maltophilia, incorporating an adult-zebrafish model of S. maltophilia infection to evaluate relative virulence coupled to 2D difference gel electrophoresis to explore underlying differences in protein expression. In this study we report upon three recent clinical isolates and use the collection strain ATCC13637 as a reference. The adult-zebrafish model shows discrimination capacity, i.e. from very low to very high mortality rates, with clinical symptoms very similar to those observed in natural S. maltophilia infections in fish. Strain virulence correlates with resistance to human serum, in agreement with previous studies in mouse and rat and therefore supporting zebrafish as a replacement model. Despite its clinical origin, the collection strain ATCC13637 showed obvious signs of attenuation in zebrafish, with null mortality. Multilocus-sequence-typing analysis revealed that the most virulent strains, UV74 and M30, exhibit the strongest genetic similitude. Differential proteomic analysis led to the identification of 38 proteins with significantly different abundance in the three clinical strains relative to the reference strain. Orthologs of several of these proteins have been already reported to have a role in pathogenesis, virulence or resistance mechanisms thus supporting our strategy. Proof of concept is further provided by protein Ax21, whose abundance is shown here to be directly proportional to mortality in the zebrafish infection model. Indeed, recent studies have demonstrated that this protein is a quorum-sensing-related virulence factor

    The oncology medical image database (OMI-DB)

    No full text

    The effect of system geometry and dose on the threshold detectable calcification diameter in 2D-mammography and digital breast tomosynthesis

    No full text
    Digital breast tomosynthesis (DBT) is under consideration to replace or to be used in combination with 2D-mammography in breast screening. The aim of this study was the comparison of the detection of microcalcification clusters by human observers in simulated breast images using 2D-mammography, narrow angle (15°/15 projections) and wide angle (50°/25 projections) DBT. The effects of the cluster height in the breast and the dose to the breast on calcification detection were also tested. Simulated images of 6 cm thick compressed breasts were produced with and without microcalcification clusters inserted, using a set of image modelling tools for 2D-mammography and DBT. Image processing and reconstruction were performed using commercial software. A series of 4-alternative forced choice (4AFC) experiments was conducted for signal detection with the microcalcification clusters as targets. Threshold detectable calcification diameter was found for each imaging modality with standard dose: 2D-mammography: 2D-mammography (165 ± 9 µm), narrow angle DBT (211 ± 11 µm) and wide angle DBT (257 ± 14 µm). Statistically significant differences were found when using different doses, but different geometries had a greater effect. No differences were found between the threshold detectable calcification diameters at different heights in the breast. Calcification clusters may have a lower detectability using DBT than 2D imaging

    Detection of microcalcification clusters by 2D-mammography and narrow and wide angle digital breast tomosynthesis

    Get PDF
    The aim of this study was to compare the detection of microcalcification clusters by human observers in breast images using 2D-mammography and narrow (15°/15 projections) and wide (50°/25 projections) angle digital breast tomosynthesis (DBT). Simulated microcalcification clusters with a range of microcalcification diameters (125 μm-275 μm) were inserted into 6 cm thick simulated compressed breasts. Breast images were produced with and without inserted microcalcification clusters using a set of image modelling tools, which were developed to represent clinical imaging by mammography and tomosynthesis. Commercially available software was used for image processing and image reconstruction. The images were then used in a series of 4-alternative forced choice (4AFC) human observer experiments conducted for signal detection with the microcalcification clusters as targets. The minimum detectable calcification diameter was found for each imaging modality: (i) 2D-mammography: 164±5 μm (ii) narrow angle DBT: 210±5 μm, (iii) wide angle DBT: 255±4 μm. A statistically significant difference was found between the minimum detectable calcification diameters that can be detected by the three imaging modalities. Furthermore, it was found that there was not a statistically significant difference between the results of the five observers that participated in this study. In conclusion, this study presents a method that quantifies the threshold diameter required for microcalcification detection, using high resolution, realistic images with observers, for the comparison of DBT geometries with 2D-mammography. 2Dmammography can visualise smaller detail diameter than both DBT imaging modalities and narrow-angle DBT can visualise a smaller detail diameter than wide-angle DBT
    corecore