363 research outputs found

    Diagnostic Ultrasound Induced Inertial Cavitation To Non-Invasively Restore Coronary And Microvascular Flow In Acute Myocardial Infarction

    Get PDF
    Ultrasound induced cavitation has been explored as a method of dissolving intravascular and microvascular thrombi in acute myocardial infarction. The purpose of this study was to determine the type of cavitation required for success, and whether longer pulse duration therapeutic impulses (sustaining the duration of cavitation) could restore both microvascular and epicardial flow with this technique. Accordingly, in 36 hyperlipidemic atherosclerotic pigs, thrombotic occlusions were induced in the mid-left anterior descending artery. Pigs were then randomized to either a) 1/2 dose tissue plasminogen activator (0.5 mg/kg) alone; or same dose plasminogen activator and an intravenous microbubble infusion with either b) guided high mechanical index short pulse (2.0 MI; 5 usec) therapeutic ultrasound impulses; or c) guided 1.0 mechanical index long pulse (20 usec) impulses. Passive cavitation detectors indicated the high mechanical index impulses (both long and short pulse duration) induced inertial cavitation within the microvasculature. Epicardial recanalization rates following randomized treatments were highest in pigs treated with the long pulse duration therapeutic impulses (83% versus 59% for short pulse, and 49% for tissue plasminogen activator alone; p \u3c 0.05). Even without epicardial recanalization, however, early microvascular recovery occurred with both short and long pulse therapeutic impulses (p \u3c 0.005 compared to tissue plasminogen activator alone), and wall thickening improved within the risk area only in pigs treated with ultrasound and microbubbles. We conclude that although short pulse duration guided therapeutic impulses from a diagnostic transducer transiently improve microvascular flow, long pulse duration therapeutic impulses produce sustained epicardial and microvascular re-flow in acute myocardial infarction

    Three-dimensional electronic instabilities in polymerized solid A1C60

    Full text link
    The low-temperature structure of A1C60 (A=K, Rb) is an ordered array of polymerized C60 chains, with magnetic properties that suggest a non-metallic ground state. We study the paramagnetic state of this phase using first-principles electronic-structure methods, and examine the magnetic fluctuations around this state using a model Hamiltonian. The electronic and magnetic properties of even this polymerized phase remain strongly three dimensional, and the magnetic fluctuations favor an unusual three-dimensional antiferromagnetically ordered structure with a semi-metallic electronic spectrum.Comment: REVTeX 3.0, 10 pages, 4 figures available on request from [email protected]

    Effects Of Attenuation And Thrombus Age On The Success Of Ultrasound And Microbubble-Mediated Thrombus Dissolution

    Get PDF
    The purpose of this study was to examine the effects of applied mechanical index, incident angle, attenuation and thrombus age on the ability of 2-D vs. 3-D diagnostic ultrasound and microbubbles to dissolve thrombi. A total of 180 occlusive porcine arterial thrombi of varying age (3 or 6 h) were examined in a flow system. A tissue-mimicking phantom of varying thickness (5 to 10 cm) was placed over the thrombosed vessel and the 2-D or 3-D diagnostic transducer aligned with the thrombosed vessel using a positioning system. Diluted lipid-encapsulated microbubbles were infused during ultrasound application. Percent thrombus dissolution (%TD) was calculated by comparison of clot mass before and after treatment. Both 2-D and 3-D-guided ultrasound increased %TD compared with microbubbles alone, but %TD achieved with 6-h-old thrombi was significantly less than 3-h-old thrombi. Thrombus dissolution was achieved at 10 cm tissue-mimicking depths, even without inertial cavitation. In conclusion, diagnostic 2-D or 3-D ultrasound can dissolve thrombi with intravenous nontargeted microbubbles, even at tissue attenuation distances of up to 10 cm. This treatment modality is less effective, however, for older aged thrombi. (E-mail: [email protected]) (C) 2011 World Federation for Ultrasound in Medicine & Biology

    Electronic Structure of Superconducting Ba6c60

    Full text link
    We report the results of first-principles electronic-structure calculations for superconducting Ba6C60. Unlike the A3C60 superconductors, this new compound shows strong Ba-C hybridization in the valence and conduction regions, mixed covalent/ionic bonding character, partial charge transfer, and insulating zero-gap band structure.Comment: 11 pages + 4 figures (1 appended, others on request), LaTeX with REVTE

    Dietary fat intake and gestational weight gain in relation to estradiol and progesterone plasma levels during pregnancy: a longitudinal study in Swedish women

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Elevated pregnancy hormone levels, such as oestrogen and progesterone, may increase the risk of developing breast cancer both in mothers and offspring. However, the reasons for large inter-individual variations in estrogen and progesterone levels during pregnancy remain unknown. The objectives of this study were to investigate whether a) intakes of total dietary fat, types of fat (monounsaturated: MUFA, polyunsaturated: n-3 and n-6 PUFA, and saturated) and b) gestational weight gain are associated with estradiol and progesterone levels in plasma during pregnancy.</p> <p>Methods</p> <p>We measured body weight as well as estradiol and progesterone in plasma among 226 healthy pregnant Swedish women on gestation weeks 12, 25 and 33. At the same time points, dietary intake of total fat and types of fat (MUFA, PUFA, SFA, n-3 and n-6 PUFA) were estimated using 3-day food diaries.</p> <p>Results</p> <p>A large variation in estradiol and progesterone levels was evident.</p> <p>Nulliparous women had 37%, 12% and 30% higher mean estradiol levels on gestation weeks 12, 25 and 33 compared to parous women (P = 0.008). No associations were found between dietary intake of total fat or fat subtypes (including n-3 PUFA and n-6 PUFA) and plasma estradiol or progesterone levels. Gestational weight gain was associated with progesterone levels (P = 0.03) but the effect was very small (20% increase in progesterone levels between gestational weeks 12 and 33 per kg body weight/week).</p> <p>Conclusion</p> <p>No associations among gestational weight gain, maternal dietary fat intake (total or subtypes including n-3 PUFA and n-6 PUFA) and plasma estradiol levels were found. However, pregnancy progesterone levels correlated with weight gain during pregnancy. Identification of other possible determinants of pregnancy estradiol and progesterone levels, important for the development of breast cancer in both mothers and offspring, are needed.</p

    Inter-site Coulomb interaction and Heisenberg exchange

    Full text link
    Based on exact diagonalization results for small clusters we discuss the effect of inter-site Coulomb repulsion in Mott-Hubbard or charge transfer insulators. Whereas the exchange constant J for direct exchange is substantially enhanced by inter-site Coulomb interaction, that for superexchange is suppressed. The enhancement of J in the single-band models holds up to the critical value for the charge density wave (CDW) instability, thus opening the way for large values of J. Single-band Hubbard models with sufficiently strong inter-site repulsion to be near a CDW instability thus may provide `physical' realizations of t-J like models with the `unphysical' parameter ratio J/t=1.Comment: Revtex file, 4 PRB pages, with 5 embedded ps-files. To appear in PRB, rapid communications. Hardcopies of figures or the entire manuscript may also be obtained by e-mail request to: [email protected]

    Frenkel and charge transfer excitons in C60

    Full text link
    We have studied the low energy electronic excitations of C60 using momentum dependent electron energy-loss spectroscopy in transmission. The momentum dependent intensity of the gap excitation allows the first direct experimental determination of the energy of the 1Hg excitation and thus also of the total width of the multiplet resulting from the gap transition. In addition, we could elucidate the nature of the following excitations - as either Frenkel or charge transfer excitons.Comment: RevTEX, 3 Figures, to appear in Phys. Rev.

    Diagnostic Ultrasound High Mechanical Index Impulses Restore Microvascular Flow In Peripheral Arterial Thromboembolism

    Get PDF
    We sought to explore mechanistically how intermittent high-mechanical-index (MI) diagnostic ultrasound impulses restore microvascular flow. Thrombotic microvascular obstruction was created in the rat hindlimb muscle of 36 rats. A diagnostic transducer confirmed occlusion with low-MI imaging during an intravenous microbubble infusion. This same transducer was used to intermittently apply ultrasound with an MI that produced stable or inertial cavitation (IC) for 10 min through a tissue-mimicking phantom. A nitric oxide inhibitor, L-Nω-nitroarginine methyl ester (L-NAME), was pre-administered to six rats. Plateau microvascular contrast intensity quantified skeletal microvascular blood volume, and postmortem staining was used to detect perivascular hemorrhage. Intermittent IC impulses produced the greatest recovery of microvascular blood volume (p \u3c 0.0001, analysis of variance). Nitric oxide inhibition did not affect the skeletal microvascular blood volume improvement, but did result in more perivascular hemorrhage. IC inducing pulses from a diagnostic transducer can reverse microvascular obstruction after acute arterial thromboembolism. Nitric oxide may prevent unwanted bio-effects of these IC pulses
    • …
    corecore