1,485 research outputs found

    Importance of characterising sleep breaks within the 24-h movement behaviour framework

    Get PDF
    Accelerometers measure the acceleration of the body part they are attached and allow to estimate time spent in activity levels (sedentary behaviour, light, and moderate-to-vigorous physical activity) and sleep over a 24-h period for several consecutive days. These advantages come with the challenges to analyse the large amount of data while integrating dimensions of both physical activity/sedentary behaviour and sleep domains. This commentary raises the questions of 1) how to classify sleep breaks (i.e. wake after sleep onset) during the night within the 24-h movement behaviour framework and 2) how to assess their impact on health while also accounting for night time sleep duration and time in sedentary behaviour and physical activity during the day. The authors advocate for future collaborations between researchers from the physical activity/sedentary behaviour and sleep research fields to ensure appropriate analysis and interpretation of the tremendous amount of data recorded by the newer generation accelerometers. This is the only way forward to provide meaningfully accurate evidence to inform future 24-h movement behaviour guidelines

    Higher Order Integrability in Generalized Holonomy

    Get PDF
    Supersymmetric backgrounds in M-theory often involve four-form flux in addition to pure geometry. In such cases, the classification of supersymmetric vacua involves the notion of generalized holonomy taking values in SL(32,R), the Clifford group for eleven-dimensional spinors. Although previous investigations of generalized holonomy have focused on the curvature \Rm_{MN}(\Omega) of the generalized SL(32,R) connection \Omega_M, we demonstrate that this local information is incomplete, and that satisfying the higher order integrability conditions is an essential feature of generalized holonomy. We also show that, while this result differs from the case of ordinary Riemannian holonomy, it is nevertheless compatible with the Ambrose-Singer holonomy theorem.Comment: 19 pages, Late

    Accelerometry analysis of physical activity and sedentary behavior in older adults: a systematic review and data analysis

    Get PDF
    Accelerometers objectively monitor physical activity and sedentary patterns and are increasingly used in the research setting. It is important to maintain consistency in data analysis and reporting, therefore, we: (1) systematically identified studies using accelerometry (ActiGraph, Pensacola, FL, USA) to measure moderate-to-vigorous physical activity (MVPA) and sedentary time in older adults, and (2) based on the review findings, we used different cut-points obtained to analyze accelerometry data from a sample of community-dwelling older women. We identified 59 articles with cut-points ranging between 574 and 3,250 counts/min for MVPA and 50 and 500 counts/min for sedentary time. Using these cut-points and data from women (mean age, 70 years), the median MVPA minutes per day ranged between 4 and 80 min while percentage of sedentary time per day ranged between 62 % and 86 %. These data highlight (1) the importance of reporting detailed information on the analysis assumptions and (2) that results can differ greatly depending on analysis parameters.E. Gorman, H. M. Hanson, P. H. Yang, K. M. Khan, T. Liu-Ambrose, M. C. Ash

    Higher intensity walking improves global cognition during inpatient rehabilitation: A secondary analysis of a randomized control trial

    Get PDF
    Cognitive deficits are common poststroke. Cognitive rehabilitation is typically used to improve cognitive deficits. It is unknown whether higher doses of exercise to promote motor recovery influence cognitive outcomes. Our recent trial, Determining Optimal Post-Stroke Exercise (DOSE), shows more than double the steps and aerobic minutes can be achieved during inpatient rehabilitation versus usual care, and translates to improved long-term walking outcomes. Thus, the secondary analysis aim was to determine the effect of the DOSE protocol on cognitive outcomes over 1-year poststroke. The DOSE protocol progressively increased step number and aerobic minutes during inpatient stroke rehabilitation over 20 sessions. The Montreal Cognitive Assessment (MoCA), Digit Symbol Substitution Test (DSST), and Trail Making Test B were completed at baseline, post-intervention, and 6- and 12-months poststroke, administered using standardized guidelines. Using the DOSE data, we used mixed-effect spline regression to model participants\u27 trajectories of cognitive recovery, controlling for relevant covariates. Participants (Usual Car

    Combining exercise with cognitive training and vitamin D

    Get PDF
    Changes in functional brain connectivity (FBC) may indicate how lifestyle modifications can prevent the progression to dementia; FBC identifies areas that are spatially separate but temporally synchronized in their activation and is altered in those with mild cognitive impairment (MCI), a prodromal state between healthy cognitive aging and dementia. Participants with MCI were randomly assigned to one of five study arms. Three times per week for 20-weeks, participants performed 30-min of (control) cognitive training, followed by 60-min of (control) physical exercise. Additionally, a vitamin

    The impact and effectiveness of the general public wearing masks to reduce the spread of pandemics in the UK: a multidisciplinary comparison of single-use masks versus reusable face masks

    Get PDF
    During the coronavirus (COVID-19) pandemic, the UK government mandated the use of face masks in various public settings and recommended the use of reusable masks to combat shortages of medically graded single-use masks in healthcare. To assist decision-making on the choice of masks for future pandemics, where shortages may not be a contributing factor, the University College London (UCL) Plastic Waste Innovation Hub has carried out a multidisciplinary comparison between single-use and reusable masks based on their anatomy, standalone effectiveness, behavioural considerations, environmental impact and costs. Although current single-use masks have a higher standalone effectiveness against bacteria and viruses, studies show that reusable masks have adequate performance in slowing infection rates of respiratory viruses. Material flow analysis (MFA), life cycle assessment (LCA) and cost comparison show that reusable masks have a lower environmental and economic impact than single-use masks. If every person in the UK uses one single-use mask each day for a year, it will create a total of 124,000 tonnes of waste, 66,000 tonnes of which would be unrecyclable contaminated plastic waste (the masks), with the rest being the recyclable packaging typically used for transportation and distribution of masks. Using reusable masks creates >85% less waste, generates 3.5 times lower impact on climate change and incurs 3.7 times lower costs. Further behavioural research is necessary to understand the extent and current practices of mask use; and how these practices affect mask effectiveness in reducing infection rates. Wearing single-use masks may be preferred over reusable masks due to perceptions of increased hygiene and convenience. Understanding behaviour towards the regular machine-washing of reusable masks for their effective reuse is key to maximise their public health benefits and minimise environmental and economic costs

    Study of J/ψppˉJ/\psi\to p\bar{p} and J/ψnnˉJ/\psi\to n\bar{n}

    Get PDF
    The decays J/ψppˉJ/\psi\to p\bar{p} and J/ψnnˉJ/\psi\to n\bar{n} have been investigated with a sample of 225.2 million J/ψJ/\psi events collected with the BESIII detector at the BEPCII e+ee^+e^- collider. The branching fractions are determined to be B(J/ψppˉ)=(2.112±0.004±0.031)×103\mathcal{B}(J/\psi\to p\bar{p})=(2.112\pm0.004\pm0.031)\times10^{-3} and B(J/ψnnˉ)=(2.07±0.01±0.17)×103\mathcal{B}(J/\psi\to n\bar{n})=(2.07\pm0.01\pm0.17)\times10^{-3}. Distributions of the angle θ\theta between the proton or anti-neutron and the beam direction are well described by the form 1+αcos2θ1+\alpha\cos^2\theta, and we find α=0.595±0.012±0.015\alpha=0.595\pm0.012\pm0.015 for J/ψppˉJ/\psi\to p\bar{p} and α=0.50±0.04±0.21\alpha=0.50\pm0.04\pm0.21 for J/ψnnˉJ/\psi\to n\bar{n}. Our branching-fraction results suggest a large phase angle between the strong and electromagnetic amplitudes describing the J/ψNNˉJ/\psi\to N\bar{N} decay.Comment: 16 pages, 13 figures, the 2nd version, submitted to PR

    Precision measurement of the branching fractions of J/psi -> pi+pi-pi0 and psi' -> pi+pi-pi0

    Get PDF
    We study the decays of the J/psi and psi' mesons to pi+pi-pi0 using data samples at both resonances collected with the BES III detector in 2009. We measure the corresponding branching fractions with unprecedented precision and provide mass spectra and Dalitz plots. The branching fraction for J/psi -> pi+pi-pi0 is determined to be (2.137 +- 0.004 (stat.) +0.058-0.056 (syst.) +0.027-0.026 (norm.))*10-2, and the branching fraction for psi' -> pi+pi-pi0 is measured as (2.14 +- 0.03 (stat.) +0.08-0.07 (syst.) +0.09-0.08 (norm.))*10-4. The J/psi decay is found to be dominated by an intermediate rho(770) state, whereas the psi' decay is dominated by di-pion masses around 2.2 GeV/c2, leading to strikingly different Dalitz distributions.Comment: 15 pages, 2 figure

    First observation of the M1 transition ψ(3686)γηc(2S)\psi(3686)\to \gamma\eta_c(2S)

    Get PDF
    Using a sample of 106 million \psi(3686) events collected with the BESIII detector at the BEPCII storage ring, we have made the first measurement of the M1 transition between the radially excited charmonium S-wave spin-triplet and the radially excited S-wave spin-singlet states: \psi(3686)\to\gamma\eta_c(2S). Analyses of the processes \psi(2S)\to \gamma\eta_c(2S) with \eta_c(2S)\to \K_S^0 K\pi and K^+K^-\pi^0 gave an \eta_c(2S) signal with a statistical significance of greater than 10 standard deviations under a wide range of assumptions about the signal and background properties. The data are used to obtain measurements of the \eta_c(2S) mass (M(\eta_c(2S))=3637.6\pm 2.9_\mathrm{stat}\pm 1.6_\mathrm{sys} MeV/c^2), width (\Gamma(\eta_c(2S))=16.9\pm 6.4_\mathrm{stat}\pm 4.8_\mathrm{sys} MeV), and the product branching fraction (\BR(\psi(3686)\to \gamma\eta_c(2S))\times \BR(\eta_c(2S)\to K\bar K\pi) = (1.30\pm 0.20_\mathrm{stat}\pm 0.30_\mathrm{sys})\times 10^{-5}). Combining our result with a BaBar measurement of \BR(\eta_c(2S)\to K\bar K \pi), we find the branching fraction of the M1 transition to be \BR(\psi(3686)\to\gamma\eta_c(2S)) = (6.8\pm 1.1_\mathrm{stat}\pm 4.5_\mathrm{sys})\times 10^{-4}.Comment: 7 pages, 1 figure, 1 tabl

    Two-photon widths of the χc0,2\chi_{c0, 2} states and helicity analysis for \chi_{c2}\ar\gamma\gamma}

    Full text link
    Based on a data sample of 106 M ψ\psi^{\prime} events collected with the BESIII detector, the decays \psi^{\prime}\ar\gamma\chi_{c0, 2},\chi_{c0, 2}\ar\gamma\gamma are studied to determine the two-photon widths of the χc0,2\chi_{c0, 2} states. The two-photon decay branching fractions are determined to be {\cal B}(\chi_{c0}\ar\gamma\gamma) = (2.24\pm 0.19\pm 0.12\pm 0.08)\times 10^{-4} and {\cal B}(\chi_{c2}\ar\gamma\gamma) = (3.21\pm 0.18\pm 0.17\pm 0.13)\times 10^{-4}. From these, the two-photon widths are determined to be Γγγ(χc0)=(2.33±0.20±0.13±0.17)\Gamma_{\gamma \gamma}(\chi_{c0}) = (2.33\pm0.20\pm0.13\pm0.17) keV, Γγγ(χc2)=(0.63±0.04±0.04±0.04)\Gamma_{\gamma \gamma}(\chi_{c2}) = (0.63\pm0.04\pm0.04\pm0.04) keV, and R\cal R =Γγγ(χc2)/Γγγ(χc0)=0.271±0.029±0.013±0.027=\Gamma_{\gamma \gamma}(\chi_{c2})/\Gamma_{\gamma \gamma}(\chi_{c0})=0.271\pm 0.029\pm 0.013\pm 0.027, where the uncertainties are statistical, systematic, and those from the PDG {\cal B}(\psi^{\prime}\ar\gamma\chi_{c0,2}) and Γ(χc0,2)\Gamma(\chi_{c0,2}) errors, respectively. The ratio of the two-photon widths for helicity λ=0\lambda=0 and helicity λ=2\lambda=2 components in the decay \chi_{c2}\ar\gamma\gamma is measured for the first time to be f0/2=Γγγλ=0(χc2)/Γγγλ=2(χc2)=0.00±0.02±0.02f_{0/2} =\Gamma^{\lambda=0}_{\gamma\gamma}(\chi_{c2})/\Gamma^{\lambda=2}_{\gamma\gamma}(\chi_{c2}) = 0.00\pm0.02\pm0.02.Comment: 10 pages, 4 figure
    corecore