19,583 research outputs found

    Regional estimation of daily to annual regional evapotranspiration with MODIS data in the Yellow River Delta wetland

    Get PDF
    Evapotranspiration (ET) from the wetland of the Yellow River Delta (YRD) is one of the important components in the water cycle, which represents the water consumption by the plants and evaporation from the water and the non-vegetated surfaces. Reliable estimates of the total evapotranspiration from the wetland is useful information both for understanding the hydrological process and for water management to protect this natural environment. Due to the heterogeneity of the vegetation types and canopy density and of soil water content over the wetland (specifically over the natural reserve areas), it is difficult to estimate the regional evapotranspiration extrapolating measurements or calculations usually done locally for a specific land cover type. Remote sensing can provide observations of land surface conditions with high spatial and temporal resolution and coverage. In this study, a model based on the Energy Balance method was used to calculate daily evapotranspiration (ET) using instantaneous observations of land surface reflectance and temperature from MODIS when the data were available on clouds-free days. A time series analysis algorithm was then applied to generate a time series of daily ET over a year period by filling the gaps in the observation series due to clouds. A detailed vegetation classification map was used to help identifying areas of various wetland vegetation types in the YRD wetland. Such information was also used to improve the parameterizations in the energy balance model to improve the accuracy of ET estimates. This study showed that spatial variation of ET was significant over the same vegetation class at a given time and over different vegetation types in different seasons in the YRD wetlan

    Vacuum induced Berry phases in single-mode Jaynes-Cummings models

    Full text link
    Motivated by the work [Phys. Rev. Lett. 89, 220404 (2002)] for detecting the vacuum-induced Berry phases with two-mode Jaynes-Cummings models (JCMs), we show here that, for a parameter-dependent single-mode JCM, certain atom-field states also acquire the photon-number-dependent Berry phases after the parameter slowly changed and eventually returned to its initial value. This geometric effect related to the field quantization still exists, even the filed is kept in its vacuum state. Specifically, a feasible Ramsey interference experiment with cavity quantum electrodynamics (QED) system is designed to detect the vacuum-induced Berry phase.Comment: 10 pages, 4 figures

    Why bortezomib cannot go with 'green'?

    Get PDF
    Eat more 'green' or eat 'five a day' is one of the most important healthy lifestyle behaviours in the 21 century. Aiming to fight cancer effectively, more than half patients use vitamins or herbs concurrently with conventional anticancer treatment. Flavonoids or polyphenols existing in vegetables, fruits and green tea are common plant pigments with antioxidant properties and considered acting as cancer preventing or anti-cancer agents. Recently it was found that some flavonoids and vitamin C in diet or supplements have antagonistic effect with the anti-cancer drug bortezomib. Bortezomib is a specific inhibitor for proteasome and is currently used for treatment of relapsed and refractory multiple myeloma. Despite its successful rates in treating multiple myeloma and other solid tumors, it is unable to kill leukemic cells in the blood. It was recently revealed that some flavonoids and vitamin C present in green leaves and green teas in the blood can neutralize bortezomib by directly interaction between two chemicals. Here we summarize why dietary flavonoids should be avoided in patients who take bortezomib as chemotherapeutic drug

    Estimation of evapotranspiration in the Mu Us Sandland of China

    Get PDF
    Evapotranspiration (ET) was estimated from 1981–2005 over Wushen County located in the Mu Us Sandland, China, by applying the Advection-Aridity model, which is based on the complementary relationship hypothesis. We used National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR), Moderate Resolution Imaging Spectroradiometer (MODIS), and meteorological data. Our results show that the estimated daily ET was about 4.5% higher than measurements using an Eddy Covariance (EC) system after forcing energy balance closure over an alfalfa field from 22 July 2004 to 23 August 2004. At a regional scale, the estimated monthly ET was about 8.7% lower than measurements using the EC system after forcing energy balance closure over an alfalfa field in August 2004. These results were about 3.0% higher than ET measurements by microlysimeter over sand dunes during June 1988. From 1981 to 2005, the average annual ET and precipitation levels were 287 mm and 336 mm, respectively, in Wushen County. The average annual ET varied from 230 mm in western parts of Wushen County to 350 mm in eastern parts of the county. Both inter-annual and seasonal variations in ET were substantial in Wushen County. The annual ET was 200–400 mm from 1981–2005, and the seasonal pattern of ET showed a single peak distribution. The cumulative ET during the June–September 2004 period was 250 mm, which was 87% of the total annual ET. The annual ET, precipitation, and the maximum Normalized Difference Vegetation Index (NDVI<sub>max</sub>) showed positive correlations temporally and spatially

    Optimal chiller loading in dual-temperature chilled water plants for energy saving

    Get PDF
    Buildings account for almost 40% of global energy consumption. Due to the high energy consumption of chilled water plants, various studies have optimized chiller loading in plants with multiple chillers for energy conservation. However, few studies have optimized dual-temperature chiller plants, even though better energy efficiency could be achieved than that of typical single-temperature chiller plants. This paper proposes two optimal control strategies for dual-temperature chilled water plants, strategy B and strategy C. Strategy B optimizes the cooling load distribution of the chillers in each group by adjusting the cooling load ratio of each chiller. Under this strategy, the energy consumption of the chiller plant for the entire cooling season was reduced by 10.1%. Meanwhile, strategy C optimizes the cooling load distribution among chillers in the same chiller group and between two chiller groups, by simultaneously adjusting the temperature setpoint of the air leaving the primary cooling coils and the partial load ratio of each chiller. By considering both the impact of the chilled water loop and the air handling process, strategy C achieved greater energy saving (16.4%) for the entire cooling season. In hot summer months, the energy savings arise mainly from optimization of the cooling load distribution among chillers in each chiller group, as this optimization accounts for 63–68% of the total savings. In moderate months, optimizing the cooling load distribution among chillers in the same group and optimizing the distribution between two chiller groups account for nearly the same proportion of the total energy savings

    A review of optimization approaches for controlling water-cooled central cooling systems

    Get PDF
    Buildings consume a large amount of energy across all sectors of society, and a large proportion of building energy is used by HVAC systems to provide a comfortable and healthy indoor environment. In medium and large-size buildings, the central cooling system accounts for a major share of the energy consumption of the HVAC system. Improving the cooling system efficiency has gained much attention as the reduction of cooling system energy use can effectively contribute to environmental sustainability. The control and operation play an important role in central cooling system energy efficiency under dynamic working conditions. It has been proven that optimization of the control of the central cooling system can notably reduce the energy consumption of the system and mitigate greenhouse gas emissions. In recent years, numerous studies focus on this topic to improve the performance of optimal control in different aspects (e.g., energy efficiency, stability, robustness, and computation efficiency). This paper provides an up-to-date overview of the research and development of optimization approaches for controlling water-cooled central cooling systems, helping readers to understand the new significant trends and achievements in this area. The optimization approaches have been classified as system-model-based and data-based. In this paper, the optimization methodology is introduced first by summarizing the key decision variables, objective function, constraints, and optimization algorithms. The principle and performance of various optimization approaches are then summarized and compared according to their classification. Finally, the challenges and development trends for optimal control of water-cooled central cooling systems are discussed

    Origin of sawtooth domain walls in ferroelectrics

    Full text link
    Domains and domain walls are among the key factors that determine the performance of ferroelectric materials. In recent years, a unique type of domain walls, i.e., the sawtooth-shaped domain walls, has been observed in BiFeO3_{3} and PbTiO3_{3}. Here, we build a minimal model to reveal the origin of these sawtooth-shaped domain walls. Incorporating this model into Monte-Carlo simulations shows that (i) the competition between the long-range Coulomb interaction (due to bound charges) and short-range interaction (due to opposite dipoles) is responsible for the formation of these peculiar domain walls and (ii) their relative strength is critical in determining the periodicity of these sawtooth-shaped domain walls. Necessary conditions to form such domain walls are also discussed

    Evaluating parameterizations of aerodynamic resistance to heat transfer using field measurements

    Get PDF
    Parameterizations of aerodynamic resistance to heat and water transfer have a significant impact on the accuracy of models of land – atmosphere interactions and of estimated surface fluxes using spectro-radiometric data collected from aircrafts and satellites. We have used measurements from an eddy correlation system to derive the aerodynamic resistance to heat transfer over a bare soil surface as well as over a maize canopy. Diurnal variations of aerodynamic resistance have been analyzed. The results showed that the diurnal variation of aerodynamic resistance during daytime (07:00 h–18:00 h) was significant for both the bare soil surface and the maize canopy although the range of variation was limited. Based on the measurements made by the eddy correlation system, a comprehensive evaluation of eight popularly used parameterization schemes of aerodynamic resistance was carried out. The roughness length for heat transfer is a crucial parameter in the estimation of aerodynamic resistance to heat transfer and can neither be taken as a constant nor be neglected. Comparing with the measurements, the parameterizations by Choudhury et al. (1986), Viney (1991), Yang et al. (2001) and the modified forms of Verma et al. (1976) and Mahrt and Ek (1984) by inclusion of roughness length for heat transfer gave good agreements with the measurements, while the parameterizations by Hatfield et al. (1983) and Xie (1988) showed larger errors even though the roughness length for heat transfer has been taken into account

    Electron Density Dependence of in-plane Spin Relaxation Anisotropy in GaAs/AlGaAs Two-Dimensional Electron Gas

    Full text link
    We investigated the spin dynamics of two-dimensional electrons in (001) GaAs/AlGaAs heterostructure using the time resolved Kerr rotation technique under a transverse magnetic field. The in-plane spin lifetime is found to be anisotropic below 150k due to the interference of Rashba and Dresselhaus spin-orbit coupling and D'yakonov-Perel' spin relaxation. The ratio of in-plane spin lifetimes is measured directly as a function of temperature and pump power, showing that the electron density in 2DEG channel strongly affects the Rashba spin-orbit coupling.Comment: 3 pages, 2 figure
    • …
    corecore