152 research outputs found

    PROSPECT guideline for total hip arthroplasty: a systematic review and procedure-specific postoperative pain management recommendations

    Get PDF
    The aim of this systematic review was to develop recommendations for the management of postoperative pain after primary elective total hip arthroplasty, updating the previous procedure-specific postoperative pain management (PROSPECT) guidelines published in 2005 and updated in July 2010. Randomised controlled trials and meta-analyses published between July 2010 and December 2019 assessing postoperative pain using analgesic, anaesthetic, surgical or other interventions were identified from MEDLINE, Embase and Cochrane databases. Five hundred and twenty studies were initially identified, of which 108 randomised trials and 21 meta-analyses met the inclusion criteria. Peri-operative interventions that improved postoperative pain include: paracetamol; cyclo-oxygenase-2-selective inhibitors; non-steroidal anti-inflammatory drugs; and intravenous dexamethasone. In addition, peripheral nerve blocks (femoral nerve block; lumbar plexus block; fascia iliaca block), single-shot local infiltration analgesia, intrathecal morphine and epidural analgesia also improved pain. Limited or inconsistent evidence was found for all other approaches evaluated. Surgical and anaesthetic techniques appear to have a minor impact on postoperative pain, and thus their choice should be based on criteria other than pain. In summary, the analgesic regimen for total hip arthroplasty should include pre-operative or intra-operative paracetamol and cyclo-oxygenase-2-selective inhibitors or non-steroidal anti-inflammatory drugs, continued postoperatively with opioids used as rescue analgesics. In addition, intra-operative intravenous dexamethasone 8-10 mg is recommended. Regional analgesic techniques such as fascia iliaca block or local infiltration analgesia are recommended, especially if there are contra-indications to basic analgesics and/or in patients with high expected postoperative pain. Epidural analgesia, femoral nerve block, lumbar plexus block and gabapentinoid administration are not recommended as the adverse effects outweigh the benefits. Although intrathecal morphine 0.1 mg can be used, the PROSPECT group emphasises the risks and side-effects associated with its use and provides evidence that adequate analgesia may be achieved with basic analgesics and regional techniques without intrathecal morphine

    Effects of early and late diabetic neuropathy on sciatic nerve block duration and neurotoxicity in Zucker diabetic fatty rats

    Get PDF
    Background The neuropathy of type II diabetes mellitus (DM) is increasing in prevalence worldwide. We aimed to test the hypothesis that in a rodent model of type II DM, neuropathy would lead to increased neurotoxicity and block duration after lidocaine-induced sciatic nerve block when compared with control animals. Methods Experiments were carried out in Zucker diabetic fatty rats aged 10 weeks (early diabetic) or 18 weeks (late diabetic, with or without insulin 3 units per day), and age-matched healthy controls. Left sciatic nerve block was performed using 0.2 ml lidocaine 2%. Nerve conduction velocity (NCV) and F-wave latency were used to quantify nerve function before, and 1 week after nerve block, after which sciatic nerves were used for neurohistopathology. Results Early diabetic animals did not show increased signs of nerve dysfunction after nerve block. In late diabetic animals without insulin vs control animals, NCV was 34.8 (5.0) vs 41.1 (4.1) ms s−1 (P<0.01), and F-wave latency was 7.7 (0.5) vs 7.0 (0.2) ms (P<0.01), respectively. Motor nerve block duration was prolonged in late diabetic animals, but neurotoxicity was not. Late diabetic animals receiving insulin showed intermediate results. Conclusions In a rodent type II DM model, nerves have increased sensitivity for short-acting local anaesthetics without adjuvants in vivo, as evidenced by prolonged block duration. This sensitivity appears to increase with the progression of neuropathy. Our results do not support the hypothesis that neuropathy due to type II DM increases the risk of nerve injury after nerve bloc

    Surveillance of high-risk early postsurgical patients for real-time detection of complications using wireless monitoring (SHEPHERD study):results of a randomized multicenter stepped wedge cluster trial

    Get PDF
    Background: Vital signs measurements on the ward are performed intermittently. This could lead to failure to rapidly detect patients with deteriorating vital signs and worsens long-term outcome. The aim of this study was to test the hypothesis that continuous wireless monitoring of vital signs on the postsurgical ward improves patient outcome. Methods: In this prospective, multicenter, stepped-wedge cluster randomized study, patients in the control group received standard monitoring. The intervention group received continuous wireless monitoring of heart rate, respiratory rate and temperature on top of standard care. Automated alerts indicating vital signs deviation from baseline were sent to ward nurses, triggering the calculation of a full early warning score followed. The primary outcome was the occurrence of new disability three months after surgery. Results: The study was terminated early (at 57% inclusion) due to COVID-19 restrictions. Therefore, only descriptive statistics are presented. A total of 747 patients were enrolled in this study and eligible for statistical analyses, 517 patients in the control group and 230 patients in the intervention group, the latter only from one hospital. New disability at three months after surgery occurred in 43.7% in the control group and in 39.1% in the intervention group (absolute difference 4.6%). Conclusion: This is the largest randomized controlled trial investigating continuous wireless monitoring in postoperative patients. While patients in the intervention group seemed to experience less (new) disability than patients in the control group, results remain inconclusive with regard to postoperative patient outcome due to premature study termination. Clinical trial registration: ClinicalTrials.gov, ID: NCT02957825.</p

    Nitric oxide synthase isoforms play distinct roles during acute peritonitis

    Get PDF
    Background. Acute peritonitis is the most frequent complication of peritoneal dialysis (PD). Increased nitric oxide (NO) release by NO synthase (NOS) isoforms has been implicated in acute peritonitis, but the role played by the NOS isoforms expressed in the peritoneum is unknown

    Electrochemistry provides a point-of-care approach for the marker indicative of Pseudomonas aeruginosa infection of cystic fibrosis patients

    Get PDF
    It has recently been demonstrated that 2-aminoacetophenone (2-AA) is a chemical indicator in exhaled air/ breath of Pseudomonas aeruginosa infection associated with progressive life threatening decline of lung function in cystic fibrosis sufferers [Scott-Thomas et al., BMC Pulm. Med., 2010, 10, 56]. Currently the detection of 2-AA involves laboratory based instrumentation such as mass spectrometry and a handheld point-of-care type breath device would be ideal in providing real-time results within seconds to accelerate patient care decision-making processes. To this end, we demonstrate proof-of-concept that the chemical marker 2-AA, indicative of Pseudomonas aeruginosa infection, can be measured using electrochemical based sensing strategies. A range of commercially available electrode substrates are explored demonstrating for the first time that 2-AA is electrochemically active within aqueous based solutions providing an (electro)analytical signal. Glassy carbon, boron-doped diamond and platinum electrodes have been explored towards the electrochemical oxidation of 2-AA. Electrode fouling is observed requiring pre-treatment in the form of mechanical polishing between voltammetric scans and measurements. To alleviate this, screen-printed graphite electrodes are shown to be a more viable option for implementation into breath sensing devices and overcome the fouling problem since due to their low cost and disposable nature, a new electrode can be used for each measurement. The analytical utility of the platinum, screen-printed and boron-doped diamond electrodes were found to correspond to 6.85, 7.66 and 4.86 mM respectively. The challenges associated with the electrochemical sensing of 2-AA in breath that need to be overcome are discussed. This generic approach where electrochemical based technology is used to provide measurements for chemical markers in exhaled air/breath for medical diagnostics termed electrochemical breathprints (ec-breathprints), has the potential to be developed into a hand-held point-of-care breath diagnostic tool for identifying Pseudomonas aeruginosa infection in exhaled air/breath
    • …
    corecore