23 research outputs found

    Using the nonlinear control of anaesthesia-induced hypersensitivity of EEG at burst suppression level to test the effects of radiofrequency radiation on brain function

    Get PDF
    Background In this study, investigating the effects of mobile phone radiation on test animals, eleven pigs were anaesthetised to the level where burst-suppression pattern appears in the electroencephalogram (EEG). At this level of anaesthesia both human subjects and animals show high sensitivity to external stimuli which produce EEG bursts during suppression. The burst-suppression phenomenon represents a nonlinear control system, where low-amplitude EEG abruptly switches to very high amplitude bursts. This switching can be triggered by very minor stimuli and the phenomenon has been described as hypersensitivity. To test if also radio frequency (RF) stimulation can trigger this nonlinear control, the animals were exposed to pulse modulated signal of a GSM mobile phone at 890 MHz. In the first phase of the experiment electromagnetic field (EMF) stimulation was randomly switched on and off and the relation between EEG bursts and EMF stimulation onsets and endpoints were studied. In the second phase a continuous RF stimulation at 31 W/kg was applied for 10 minutes. The ECG, the EEG, and the subcutaneous temperature were recorded. Results No correlation between the exposure and the EEG burst occurrences was observed in phase I measurements. No significant changes were observed in the EEG activity of the pigs during phase II measurements although several EEG signal analysis methods were applied. The temperature measured subcutaneously from the pigs' head increased by 1.6°C and the heart rate by 14.2 bpm on the average during the 10 min exposure periods. Conclusion The hypothesis that RF radiation would produce sensory stimulation of somatosensory, auditory or visual system or directly affect the brain so as to produce EEG bursts during suppression was not confirmed.BioMed Central Open acces

    Results of Monitoring at Olkiluoto in 2016. Environment

    No full text
    201

    Electroencephalogram desynchronization in brain trauma patients

    No full text

    >

    No full text

    A new method for evaluating the performance of depth-of-hypnosis indices - the D-value

    No full text
    Abstract: An alternative statistic, the D-value, is presented for the evaluation of the performance of EEG-based depth-of-hypnosis measures against the Observers' Assessment of Alertness/Sedation scale. The measures considered here are spectral entropy, approximate entropy, Lempel-Ziv complexity and Higuchi fractal dimension. The study is based on recordings from 45 patients, divided into three groups of 15 recordings each. Patients of Group I received no remifentanil while patients of Groups H and M received 2 and 4 ng/ml effect compartment controlled remifentanil. All the patients received stepwise increased dose of propofol. The study shows that the D-value is a promising and flexible statistic for the evaluation of the discriminative power of the EEG measures with respect to the OAA/S scale. The D-value indicates well the dependence of the performance of the measures on the EEG frequency band as well as on remifentanil concentration

    Non-linear algorithms for processing biological signals

    No full text
    This paper illustrates different approaches to the analysis of biological signals based on non-linear methods. The performance of such approaches, despite the greater methodological and computational complexity is, in many instances, more successful compared to linear approaches, in enhancing important parameters for both physiological studies and clinical protocols. The methods introduced employ median filters for pattern recognition, adaptive segmentation, data compression, prediction and data modelling as well as multivariate estimators in data clustering through median learning vector quantizers. Another approach described uses Wiener-Volterra kernel technique to obtain a satisfactory estimation and causality test among EEG recordings. Finally, methods for the assessment of non-linear dynamic behaviour are discussed and applied to the analysis of heart rate variability signal. In this way invariant parameters are studied which describe non-linear phenomena in the modelling of the physiological systems under investigation

    Patient-Specific Seizure Detection Using Nonlinear Dynamics and Nullclines

    No full text
    Nonlinear dynamics has recently been extensively used to study epilepsy due to the complex nature of the neuronal systems. This study presents a novel method that characterizes the dynamic behavior of pediatric seizure events and introduces a systematic approach to locate the nullclines on the phase space when the governing differential equations are unknown. Nullclines represent the locus of points in the solution space where the components of the velocity vectors are zero. A simulation study over 5 benchmark nonlinear systems with well-known differential equations in three-dimensional exhibits the characterization efficiency and accuracy of the proposed approach that is solely based on the reconstructed solution trajectory. Due to their unique characteristics in the nonlinear dynamics of epilepsy, discriminative features can be extracted based on the nullclines concept. Using a limited training data (only 25% of each EEG record) in order to mimic the real-world clinical practice, the proposed approach achieves 91.15% average sensitivity and 95.16% average specificity over the benchmark CHB-MIT dataset. Together with an elegant computational efficiency, the proposed approach can, therefore, be an automatic and reliable solution for patient-specific seizure detection in long EEG recordings.Scopu
    corecore