    Progress toward the development of dual junction GaAs/Ge solar cells

    Get PDF
    Large area GaAs/Ge cells offer substantial promise for increasing the power output from existing silicon solar array designs and for providing an enabled technology for missions hitherto impossible using silicon. Single junction GaAs/Ge cells offer substantial advantages in both size, weight, and cost compared to GaAs cells but the efficiency is limited to approximately 19.2 to 20 percent AMO. The thermal absorptance of GaAs/Ge cells is also worse than GaAs/GaAs cells (0.88 vs 0.81 typ.) due to the absorption in the Ge substrate. On the other hand dual junction GaAs/Ge cells offer efficiencies up to ultimately 24 percent AMO in sizes up to 8 x 8 cm but there are still technological issues remaining to achieve current matching in the GaAs and Ge cells. This can be achieved through tuned antireflection (AR) coatings, improved quality of the GaAs growth, improved quality Ge wafers and the use of a Back Surface Field (BSF)/Back Surface Reflector (BSR) in the Ge cell. Although the temperature coefficients of efficiency and voltage are higher for dual junction GaAs/Ge cells, it has been shown elsewhere that for typical 28 C cell efficiencies of 22 percent (dual junction) vs 18.5 percent (single junction) there is a positive power tradeoff up to temperatures as high as 120 C. Due to the potential ease of fabrication of GaAs/Ge dual junction cells there is likely to be only a small cost differential compared to single junction cells

    Production status of GaAs/Ge solar cells and panels

    Get PDF
    GaAs/Ge solar cells with lot average efficiencies in excess of 18 percent were produced by MOCVD growth techniques. A description of the cell, its performance and the production facility are discussed. Production GaAs/Ge cells of this type were recently assembled into circuits and bonded to aluminum honeycomb panels to be used as the solar array for the British UOSAT-F program

    High efficiency GaAs-Ge tandem solar cells grown by MOCVD

    Get PDF
    High conversion efficiency and low weight are obviously desirable for solar cells intended for space applications. One promising structure is GaAs on Ge. The advantages of using Ge wafers as substrates include the following: they offer high efficiency by forming a two-junction tandem cell; low weight combined with superior strength allows usage of thin (3 mil) wafers; and they are a good substrate for GaAs, being lattice matched, thermal expansion matched, and available as large-area wafers

    PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques

    Get PDF
    Positron emission tomography/magnetic resonance imaging (PET/MRI) potentially offers several advantages over positron emission tomography/computed tomography (PET/CT), for example, no CT radiation dose and soft tissue images from MR acquired at the same time as the PET. However, obtaining accurate linear attenuation correction (LAC) factors for the lung remains difficult in PET/MRI. LACs depend on electron density and in the lung, these vary significantly both within an individual and from person to person. Current commercial practice is to use a single-valued population-based lung LAC, and better estimation is needed to improve quantification. Given the under-appreciation of lung attenuation estimation as an issue, the inaccuracy of PET quantification due to the use of single-valued lung LACs, the unique challenges of lung estimation, and the emerging status of PET/MRI scanners in lung disease, a review is timely. This paper highlights past and present methods, categorizing them into segmentation, atlas/mapping, and emission-based schemes. Potential strategies for future developments are also presented

    Does the availability of positron emission tomography modify diagnostic strategies for solitary pulmonary nodules? An observational study in France

    Get PDF
    International audienceBACKGROUND: Previous studies showed that at the individual level, positron emission tomography (PET) has some benefits for patients and physicians in terms of cancer management and staging. We aimed to describe the benefits of (PET) in the management of solitary pulmonary nodules (SPNs) in a population level, in terms of the number of diagnostic and invasive tests performed, time to diagnosis and factors determining PET utilization. METHODS: In an observational study, we examined reports of computed tomography (CT) performed and mentioning "spherical lesion", "nodule" or synonymous terms. We found 11,515 reports in a before-PET period, 2002-2003, and 20,075 in an after-PET period, 2004-2005. Patients were followed through their physician, who was responsible for diagnostic management. RESULTS: We had complete data for 112 patients (73.7%) with new cases of SPN in the before-PET period and 250 (81.4%) in the after-PET period. Patients did not differ in mean age (64.9 vs. 64.8 years). The before-PET patients underwent a mean of 4 tests as compared with 3 tests for the after-PET patients (p = 0.08). Patients in the before-PET period had to wait 41.4 days, on average, before receiving a diagnosis as compared with 24.0 days, on average, for patients in the after-PET period who did not undergo PET (p < 0.001). In the after-PET period, 11% of patients underwent PET during the diagnostic process. A spiculated nodule was more likely to determine prescription for PET (p < 0.001). Multivariate analysis revealed that patients in both periods underwent fewer tests when PET was prescribed by general practitioners (p < 0.001) and if the nodule was not spiculated (p < 0.001). The proportion of unnecessary invasive approaches prescribed (47% vs. 49%) did not differ between the groups. CONCLUSION: In our study, 1 year after the availability of PET, the technology was not the first choice for diagnostic management of SPN. Even though we observed a tendency for reduced number of tests and mean time to diagnosis with PET, these phenomena did not fully relate to PET availability in health communities. In addition, the availability of PET in the management of SPN diagnosis did not reduce the overall rate of unnecessary invasive approaches

    18F-fluoro-deoxy-glucose focal uptake in very small pulmonary nodules: fact or artifact? Case reports

    Get PDF
    ABSTRACT: BACKGROUND: F-fluoro-deoxy-glucose (18F-FDG) positron emission tomography integrated/combined with computed tomography (PET-CT) provides the best diagnostic results in the metabolic characterization of undetermined solid pulmonary nodules. The diagnostic performance of 18F-FDG is similar for nodules measuring at least 1 cm and for larger masses, but few data exist for nodules smaller than 1 cm. CASE PRESENTATION: We report five cases of oncologic patients showing focal lung 18F-FDG uptake on PET-CT in nodules smaller than 1 cm. We also discuss the most common causes of 18F-FDG false-positive and false-negative results in the pulmonary parenchyma. In patient 1, contrast-enhanced CT performed 10 days before PET-CT did not show any abnormality in the site of uptake; in patient 2, high-resolution CT performed 1 month after PET showed a bronchiole filled with dense material interpreted as a mucoid impaction; in patient 3, contrast-enhanced CT performed 15 days before PET-CT did not identify any nodules; in patients 4 and 5, contrast-enhanced CT revealed a nodule smaller than 1 cm which could not be characterized. The 18F-FDG uptake at follow-up confirmed the malignant nature of pulmonary nodules smaller than 1 cm which were undetectable, misinterpreted, not recognized or undetermined at contrast-enhanced CT. CONCLUSION: In all five oncologic patients, 18F-FDG was able to metabolically characterize as malignant those nodules smaller than 1 cm, underlining that: 18F-FDG uptake is not only a function of tumor size but it is strongly related to the tumor biology; functional alterations may precede morphologic abnormalities. In the oncologic population, especially in higher-risk patients, PET can be performed even when the nodules are smaller than 1 cm, because it might give an earlier characterization and, sometimes, could guide in the identification of alterations missed on CT

    Development of an inflammatory bowel disease (IBD) Patient‐Reported Experience Measure (PREM): A patient‐led consensus work and ‘think aloud’ study for a quality improvement programme

    Get PDF
    Background Patient-Reported Experience Measures (PREMs) are key in improving healthcare quality, but no PREM exists for inflammatory bowel disease (IBD). This study aimed to co-produce a PREM with IBD service users for IBD service evaluation and quality improvement programme. Methods A pool of 75 items was drawn from published survey instruments covering interactions with services and aspects of living with IBD. In Stage 1, during two workshops, eight expert service users reduced candidate items through a ranked-choice voting exercise and suggested further items. During Stage 2, 18 previously uninvolved people with IBD assessed the face and content validity of the candidate items in ‘Think Aloud’ interviews. During two final workshops (Stage 3), the expert service users removed, modified and added items based on the interview findings to produce a final version of the PREM. Results Stage 1 generated a draft working PREM mapped to the following four domains: Patient-Centred Care; Quality; Accessibility; Communication and Involvement. The PREM included a set of nine items created by the expert group which shifted the emphasis from ‘self-management’ to ‘living with IBD’. Stage 2 interviews showed that comprehension of the PREM was very good, although there were concerns about the wording, IBD-relevance and ambiguity of some items. During the final two workshops in Stage 3, the expert service users removed 7 items, modified 15 items and added seven new ones based on the interview findings, resulting in a 38-item PREM. Conclusions This study demonstrates how extensive service user involvement can inform PREM development. Patient or Public Contribution Patients were involved as active members of the research team and as research participants to co-produce and validate a PREM for IBD services. In Stage 1, eight expert service users (‘the expert group’) reduced candidate items for the PREM through a voting exercise and suggested new items. During Stage 2, 18 previously uninvolved people with IBD (the ‘think aloud’ participants) assessed the validity of the candidate items in ‘Think Aloud’ interviews as research participants. In Stage 3, the expert group removed, changed and added items based on the interview findings to produce a final version of the 38-item PREM. This study shows how service user involvement can meaningfully inform PREM development

    Cdh11 Acts as a Tumor Suppressor in a Murine Retinoblastoma Model by Facilitating Tumor Cell Death

    Get PDF
    CDH11 gene copy number and expression are frequently lost in human retinoblastomas and in retinoblastomas arising in TAg-RB mice. To determine the effect of Cdh11 loss in tumorigenesis, we crossed Cdh11 null mice with TAg-RB mice. Loss of Cdh11 had no gross morphological effect on the developing retina of Cdh11 knockout mice, but led to larger retinal volumes in mice crossed with TAg-RB mice (p = 0.01). Mice null for Cdh11 presented with fewer TAg-positive cells at postnatal day 8 (PND8) (p = 0.01) and had fewer multifocal tumors at PND28 (p = 0.016), compared to mice with normal Cdh11 alleles. However, tumor growth was faster in Cdh11-null mice between PND8 and PND84 (p = 0.003). In tumors of Cdh11-null mice, cell death was decreased 5- to 10-fold (p<0.03 for all markers), while proliferation in vivo remained unaffected (p = 0.121). Activated caspase-3 was significantly decreased and β-catenin expression increased in Cdh11 knockdown experiments in vitro. These data suggest that Cdh11 displays tumor suppressor properties in vivo and in vitro in murine retinoblastoma through promotion of cell death