19 research outputs found

    Offspring Hormones Reflect the Maternal Prenatal Social Environment: Potential for Foetal Programming?

    Get PDF
    Females of many species adaptively program their offspring to predictable environmental conditions, a process that is often mediated by hormones. Laboratory studies have shown, for instance, that social density affects levels of maternal cortisol and testosterone, leading to fitness-relevant changes in offspring physiology and behaviour. However, the effects of social density remain poorly understood in natural populations due to the difficulty of disentangling confounding influences such as climatic variation and food availability. Colonially breeding marine mammals offer a unique opportunity to study maternal effects in response to variable colony densities under similar ecological conditions. We therefore quantified maternal and offspring hormone levels in 84 Antarctic fur seals (Arctocephalus gazella) from two closely neighbouring colonies of contrasting density. Hair samples were used as they integrate hormone levels over several weeks or months and therefore represent in utero conditions during foetal development. We found significantly higher levels of cortisol and testosterone (both P < 0.001) in mothers from the high density colony, reflecting a more stressful and competitive environment. In addition, offspring testosterone showed a significant positive correlation with maternal cortisol (P < 0.05). Although further work is needed to elucidate the potential consequences for offspring fitness, these findings raise the intriguing possibility that adaptive foetal programming might occur in fur seals in response to the maternal social environment. They also lend support to the idea that hormonally mediated maternal effects may depend more strongly on the maternal regulation of androgen rather than cortisol levels

    Search for invisible modes of nucleon decay in water with the SNO+ detector

    Get PDF
    This paper reports results from a search for nucleon decay through invisible modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently deexcite, often emitting detectable gamma rays. A search for such gamma rays yields limits of 2.5×1029  y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and 3.6×1029  y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of 1.3×1028  y for nn, 2.6×1028  y for pn and 4.7×1028  y for pp, an improvement over existing limits by close to 3 orders of magnitude for the latter two

    Measurement of IWTO-19 ash content by Near Infrared Reflectance (NIR) Analysis

    No full text
    The prediction of ash content of laboratory-scoured core samples utilising Near Infrared Reflectance Analysis (NIRA) has been investigated. Modified Partial Least Squares (MPLS) Regression was found to underestimate ash content when the sample being tested contained significant quantities of dag. The underestimation was not a consequence of saturation of the NIRA detector but rather appeared to be due to an inability of the MPLS technique to adequately account for dag which was present in the sample but masked by wool. Application of Artificial Neu ral Networks (ANN) Regression to the calibration data set produced improved results. The underestimation at higher ash levels was not as evident, indicating that ANN is better able to utilise the spectral information to predict total ash content. High levels of dag were found to adversely affect the repeatability of the IWTO-19 method for determining ash content. Uneven distribution of dag within samples was believed to be responsible. This finding has implications for NIRA, as any method of prediction can only be as good as the reference method to which it is calibrated

    Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1

    No full text
    The DEAP-1 low-background liquid argon detector has been used to measure scintillation pulse shapes of beta decays and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination down to an electron-equivalent energy of 20 keVee. The relative intensities of singlet/triplet states in liquid argon have been measured as a function of energy between 15 and 500 keVee for both beta and nuclear recoils. Using a triple-coincidence tag we find the fraction of beta events that are mis-identified as nuclear recoils to be less than 6x10^{-8} between 43-86 keVee and that the discrimination parameter agrees with a simple analytic model. The discrimination measurement is currently limited by nuclear recoils induced by cosmic-ray generated neutrons, and is expected to improve by operating the detector underground at SNOLAB. The analytic model predicts a beta mis-identification fraction of 10^{-10} for an electron-equivalent energy threshold of 20 keVee. This reduction allows for a sensitive search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of 10^{-46} cm^{2}

    First results from the DEAP-3600 dark matter search with argon at SNOLAB

    No full text
    This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage <1.2\times 10^{-7} (90% C.L.) between 16 and 33 keVee_{ee}. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, <1.2\times 10^{-44} cm2^2 for a 100 GeV/c2^2 WIMP mass (90% C.L.)
    corecore