20 research outputs found

    Measurement and data transmission validity of a multi-biosensor system for real-time remote exercise monitoring among cardiac patients

    Full text link
    Background: Remote telemonitoring holds great potential to augment management of patients with coronary heart disease (CHD) and atrial fibrillation (AF) by enabling regular physiological monitoring during physical activity. Remote physiological monitoring may improve home and community exercise-based cardiac rehabilitation (exCR) programs and could improve assessment of the impact and management of pharmacological interventions for heart rate control in individuals with AF.Objective: Our aim was to evaluate the measurement validity and data transmission reliability of a remote telemonitoring system comprising a wireless multi-parameter physiological sensor, custom mobile app, and middleware platform, among individuals in sinus rhythm and AF.Methods: Participants in sinus rhythm and with AF undertook simulated daily activities, low, moderate, and/or high intensity exercise. Remote monitoring system heart rate and respiratory rate were compared to reference measures (12-lead ECG and indirect calorimeter). Wireless data transmission loss was calculated between the sensor, mobile app, and remote Internet server.Results: Median heart rate (-0.30 to 1.10 b∙min-1) and respiratory rate (-1.25 to 0.39 br∙min-1) measurement biases were small, yet statistically significant (all P≤.003) due to the large number of observations. Measurement reliability was generally excellent (rho=.87-.97, all P<.001; intraclass correlation coefficient [ICC]=.94-.98, all P<.001; coefficient of variation [CV]=2.24-7.94%), although respiratory rate measurement reliability was poor among AF participants (rho=.43, P<.001; ICC=.55, P<.001; CV=16.61%). Data loss was minimal (<5%) when all system components were active; however, instability of the network hosting the remote data capture server resulted in data loss at the remote Internet server during some trials.Conclusions: System validity was sufficient for remote monitoring of heart and respiratory rates across a range of exercise intensities. Remote exercise monitoring has potential to augment current exCR and heart rate control management approaches by enabling the provision of individually tailored care to individuals outside traditional clinical environments

    ILEEM-survey on the Heart Team approach and team training for lead extraction procedures

    Get PDF
    Background: The Heart Team approach has become an integral part of modern cardiovascular medicine. To evaluate current opinions and real-world practice among lead extraction practitioners, an online survey was created and distributed among a pool of lead extraction specialists participating in the International Lead Extraction Expert Meeting (ILEEM) 2018. Methods: The online survey consisted of 10 questions and was performed using an online survey tool (www.surveymonkey.com). The collector link was sent to 48 lead extraction experts via email. Results: A total of 43 answers were collected (89% return rate) from lead extraction experts in 16 different countries. A great majority (83.7%) of the respondents performed more than 30 lead extraction procedures per year. The most common procedural environment in this survey was the hybrid operating room (67.4%). Most procedures were performed by electrophysiologists and cardiologists (80.9%). Important additional members of the current lead extraction teams were cardiac surgeons (79.1%), anesthesiologists (95.3%) and operating room scrub nurses (76.7%). An extended Heart Team is regarded beneficial for patient care by 86.0%, with potential further members being infectious diseases specialists, intensivists and radiologists. Team training activities are performed in 48.8% of participating centers. Conclusions: This survey supports the importance of establishing lead extraction Heart Teams in specialized lead extraction centers to potentially improve patient outcomes. The concept of a core and an extended heart team approach in lead extraction procedures is introduced

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Desynchronization in a cardiac resynchronization device induced by a pacemaker-mediated tachycardia algorithm

    No full text
    This report describes the occurrence of desynchronization in a patient with a cardiac resynchronization device programmed with an active pacemaker-mediated tachycardia algorithm based on AV delay modification. Desynchronization was precipitated by sinus tachycardia and the abrupt return of the prevailing AV delay that followed the periodic prolongation of the AV delay mandated by activity of the algorithm. Prevention of desynchronization in this setting requires programming a right ventricular upper rate interval longer than the sum of the programmed ventriculoatrial interval and the AV delay

    ILEEM-survey on the Heart Team approach and team training for lead extraction procedures

    Get PDF
    BACKGROUND The Heart Team approach has become an integral part of modern cardiovascular medicine. To evaluate current opinions and real-world practice among lead extraction practitioners, an online survey was created and distributed among a pool of lead extraction specialists participating in the International Lead Extraction Expert Meeting (ILEEM) 2018. METHODS The online survey consisted of 10 questions and was performed using an online survey tool (www.surveymonkey.com). The collector link was sent to 48 lead extraction experts via email. RESULTS A total of 43 answers were collected (89% return rate) from lead extraction experts in 16 different countries. A great majority (83.7%) of the respondents performed more than 30 lead extraction procedures per year. The most common procedural environment in this survey was the hybrid operating room (67.4%). Most procedures were performed by electrophysiologists and cardiologists (80.9%). Important additional members of the current lead extraction teams were cardiac surgeons (79.1%), anesthesiologists (95.3%) and operating room scrub nurses (76.7%). An extended Heart Team is regarded beneficial for patient care by 86.0%, with potential further members being infectious diseases specialists, intensivists and radiologists. Team training activities are performed in 48.8% of participating centers. CONCLUSIONS This survey supports the importance of establishing lead extraction Heart Teams in specialized lead extraction centers to potentially improve patient outcomes. The concept of a core and an extended heart team approach in lead extraction procedures is introduced

    Novel cryoballoon to isolate pulmonary veins in patients with paroxysmal atrial fibrillation: long-term outcomes in a multicentre clinical study

    Get PDF
    Background: Recently, a novel cryoballoon ablation catheter has demonstrated acute safety and efficacy in de novo pulmonary vein isolation (PVI) procedures in patients with paroxysmal atrial fibrillation (PAF). However, there are limited studies demonstrating the long-term efficacy. The aim of this study was to evaluate the long-term safety and efficacy of this novel cryoballoon in treating PAF. Methods: This was a non-randomized, prospective, multicentre study enrolling 58 consecutive patients. Cryoablation was delivered for 180 s if time to isolation was ≤ 60 s. Otherwise a 240-s cryoablation was performed. One centre performed pre- and post-ablation high-density mapping (n = 9) to characterize lesion formation. After a 3-month blanking period, recurrence was defined as having any documented, symptomatic episode(s) of AF or atrial tachycardia. All patients were followed for 1 year. Results: Acute PVI was achieved in 230 of 231 pulmonary veins (99.6%) with 5.3 ± 1.6 cryoablations per patient (1.3 ± 0.7 cryoablations per vein). Forty-three (77%) patients remained arrhythmia-free at 1-year follow-up. Four patients (6.9%) experienced phrenic nerve injury (3 resolved during the index procedure; 1 resolved at 6 months). One serious adverse device event was reported: femoral arterial embolism event occurring 2 weeks post-index procedure. For patients who underwent high-density mapping, cryoablation was antral with 50% of the posterior wall ablated. Conclusions: Initial multicentre clinical experience with a novel cryoballoon has demonstrated safety and efficacy of PVI in patients with PAF. Ablation with this cryoballoon provides a wide, antral lesion set with significant debulking of the posterior wall of the left atrium
    corecore