35 research outputs found

    Identification of Volatile Compounds and Selection of Discriminant Markers for Elephant Dung Coffee Using Static Headspace Gas Chromatography—Mass Spectrometry and Chemometrics

    No full text
    Elephant dung coffee (Black Ivory Coffee) is a unique Thai coffee produced from Arabica coffee cherries consumed by Asian elephants and collected from their feces. In this work, elephant dung coffee and controls were analyzed using static headspace gas chromatography hyphenated with mass spectrometry (SHS GC-MS), and chemometric approaches were applied for multivariate analysis and the selection of marker compounds that are characteristic of the coffee. Seventy-eight volatile compounds belonging to 13 chemical classes were tentatively identified, including six alcohols, five aldehydes, one carboxylic acid, three esters, 17 furans, one furanone, 13 ketones, two oxazoles, four phenolic compounds, 14 pyrazines, one pyridine, eight pyrroles and three sulfur-containing compounds. Moreover, four potential discriminant markers of elephant dung coffee, including 3-methyl-1-butanol, 2-methyl-1-butanol, 2-furfurylfuran and 3-penten-2-one were established. The proposed method may be useful for elephant dung coffee authentication and quality control

    Liquid chromatographic-mass spectrometric method for simultaneous determination of small organic acids potentially contributing to acidosis in severe malaria.

    No full text
    Acidosis is an important cause of mortality in severe falciparum malaria. Lactic acid is a major contributor to metabolic acidosis, but accounts for only one-quarter of the strong anion gap. Other unidentified organic acids have an independent strong prognostic significance for a fatal outcome. In this study, a simultaneous bio-analytical method for qualitative and quantitative assessment in plasma and urine of eight small organic acids potentially contributing to acidosis in severe malaria was developed and validated. High-throughput strong anion exchange solid-phase extraction in a 96-well plate format was used for sample preparation. Hydrophilic interaction liquid chromatography (HILIC) coupled to negative mass spectroscopy was utilized for separation and detection. Eight possible small organic acids; l-lactic acid (LA), α-hydroxybutyric acid (aHBA), β-hydroxybutyric acid (bHBA), p-hydroxyphenyllactic acid (pHPLA), malonic acid (MA), methylmalonic acid (MMA), ethylmalonic acid (EMA) and α-ketoglutaric acid (aKGA) were analyzed simultaneously using a ZIC-HILIC column with an isocratic elution containing acetonitrile and ammonium acetate buffer. This method was validated according to U.S. Food and Drug Administration guidelines with additional validation procedures for endogenous substances. Accuracy for all eight acids ranged from 93.1% to 104.0%, and the within-day and between-day precisions (i.e. relative standard deviations) were lower than 5.5% at all tested concentrations. The calibration ranges were: 2.5-2500μg/mL for LA, 0.125-125μg/mL for aHBA, 7.5-375μg/mL for bHBA, 0.1-100μg/mL for pHPLA, 1-1000μg/mL for MA, 0.25-250μg/mL for MMA, 0.25-100μg/mL for EMA, and 30-1500μg/mL for aKGA. Clinical applicability was demonstrated by analyzing plasma and urine samples from five patients with severe falciparum malaria; five acids had increased concentrations in plasma (range LA=177-1169μg/mL, aHBA=4.70-38.4μg/mL, bHBA=7.70-38.0μg/mL, pHPLA=0.900-4.30μg/mL and aKGA=30.2-32.0) and seven in urine samples (range LA=11.2-513μg/mL, aHBA=1.50-69.5μg/mL, bHBA=8.10-111μg/mL, pHPLA=4.30-27.7μg/mL, MMA=0.300-13.3μg/mL, EMA=0.300-48.1μg/mL and aKGA=30.4-107μg/mL). In conclusion, a novel bioanalytical method was developed and validated which allows for simultaneous quantification of eight small organic acids in plasma and urine. This new method may be a useful tool for the assessment of acidosis in patients with severe malaria, and other conditions complicated by acidosis

    Qualitative Aspects in the Analysis of Pesticide Residues in Fruits and Vegetables Using Fast, Low -Pressure Gas Chromatography-Time-of-Flight Mass Spectrometry

    No full text
    Quantitative method validation is a well-established process to demonstrate trueness and precision of the results with a given method. However, an assessment of qualitative results is also an important need to estimate selectivity and devise criteria for chemical identification when using the method, particularly for mass spectrometric analysis. For multianalyte analysis, automatic instrument software is commonly used to make initial qualitative identifications of the target analytes by comparison of their mass spectra against a database library. Especially at low residue levels in complex matrices, manual checking of results is typically needed to correct the peak assignments and integration errors, which is very time-consuming. Low-pressure gas chromatography-mass spectrometry (LP-GC-MS) has been demonstrated to increase the speed of analysis for GC-amenable residues in various foods and provide more advantages over the traditional GC-MS approach. LP-GC-MS on a time-of-flight (ToF) instrument was used, which provided high sample throughput wit

    Liquid chromatographic-mass spectrometric method for simultaneous determination of small organic acids potentially contributing to acidosis in severe malaria.

    No full text
    Acidosis is an important cause of mortality in severe falciparum malaria. Lactic acid is a major contributor to metabolic acidosis, but accounts for only one-quarter of the strong anion gap. Other unidentified organic acids have an independent strong prognostic significance for a fatal outcome. In this study, a simultaneous bio-analytical method for qualitative and quantitative assessment in plasma and urine of eight small organic acids potentially contributing to acidosis in severe malaria was developed and validated. High-throughput strong anion exchange solid-phase extraction in a 96-well plate format was used for sample preparation. Hydrophilic interaction liquid chromatography (HILIC) coupled to negative mass spectroscopy was utilized for separation and detection. Eight possible small organic acids; l-lactic acid (LA), α-hydroxybutyric acid (aHBA), β-hydroxybutyric acid (bHBA), p-hydroxyphenyllactic acid (pHPLA), malonic acid (MA), methylmalonic acid (MMA), ethylmalonic acid (EMA) and α-ketoglutaric acid (aKGA) were analyzed simultaneously using a ZIC-HILIC column with an isocratic elution containing acetonitrile and ammonium acetate buffer. This method was validated according to U.S. Food and Drug Administration guidelines with additional validation procedures for endogenous substances. Accuracy for all eight acids ranged from 93.1% to 104.0%, and the within-day and between-day precisions (i.e. relative standard deviations) were lower than 5.5% at all tested concentrations. The calibration ranges were: 2.5-2500μg/mL for LA, 0.125-125μg/mL for aHBA, 7.5-375μg/mL for bHBA, 0.1-100μg/mL for pHPLA, 1-1000μg/mL for MA, 0.25-250μg/mL for MMA, 0.25-100μg/mL for EMA, and 30-1500μg/mL for aKGA. Clinical applicability was demonstrated by analyzing plasma and urine samples from five patients with severe falciparum malaria; five acids had increased concentrations in plasma (range LA=177-1169μg/mL, aHBA=4.70-38.4μg/mL, bHBA=7.70-38.0μg/mL, pHPLA=0.900-4.30μg/mL and aKGA=30.2-32.0) and seven in urine samples (range LA=11.2-513μg/mL, aHBA=1.50-69.5μg/mL, bHBA=8.10-111μg/mL, pHPLA=4.30-27.7μg/mL, MMA=0.300-13.3μg/mL, EMA=0.300-48.1μg/mL and aKGA=30.4-107μg/mL). In conclusion, a novel bioanalytical method was developed and validated which allows for simultaneous quantification of eight small organic acids in plasma and urine. This new method may be a useful tool for the assessment of acidosis in patients with severe malaria, and other conditions complicated by acidosis

    Qualitative Aspects in the Analysis of Pesticide Residues in Fruits and Vegetables Using Fast, Low -Pressure Gas Chromatography-Time-of-Flight Mass Spectrometry

    No full text
    Quantitative method validation is a well-established process to demonstrate trueness and precision of the results with a given method. However, an assessment of qualitative results is also an important need to estimate selectivity and devise criteria for chemical identification when using the method, particularly for mass spectrometric analysis. For multianalyte analysis, automatic instrument software is commonly used to make initial qualitative identifications of the target analytes by comparison of their mass spectra against a database library. Especially at low residue levels in complex matrices, manual checking of results is typically needed to correct the peak assignments and integration errors, which is very time-consuming. Low-pressure gas chromatography-mass spectrometry (LP-GC-MS) has been demonstrated to increase the speed of analysis for GC-amenable residues in various foods and provide more advantages over the traditional GC-MS approach. LP-GC-MS on a time-of-flight (ToF) instrument was used, which provided high sample throughput wit
    corecore