9 research outputs found

    Optimization and evaluation of a live virus SARS-CoV-2 neutralization assay

    Get PDF
    Virus neutralization assays provide a means to quantitate functional antibody responses that block virus infection. These assays are instrumental in defining vaccine and therapeutic antibody potency, immune evasion by viral variants, and post-infection immunity. Here we describe the development, optimization and evaluation of a live virus microneutralization assay specific for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this assay, SARS-CoV-2 clinical isolates are pre-incubated with serial diluted antibody and added to Vero E6 cells. Replicating virus is quantitated by enzyme-linked immunosorbent assay (ELISA) targeting the SARS-CoV-2 nucleocapsid protein and the standardized 50% virus inhibition titer calculated. We evaluated critical test parameters that include virus titration, assay linearity, number of cells, viral dose, incubation period post-inoculation, and normalization methods. Virus titration at 96 hours was determined optimal to account for different growth kinetics of clinical isolates. Nucleocapsid protein levels directly correlated with virus inoculum, with the strongest correlation at 24 hours post-inoculation. Variance was minimized by infecting a cell monolayer, rather than a cell suspension. Neutralization titers modestly decreased with increasing numbers of Vero E6 cells and virus amount. Application of two different normalization models effectively reduced the intermediate precision coefficient of variance to <16.5%. The SARS-CoV-2 microneutralization assay described and evaluated here is based on the influenza virus microneutralization assay described by WHO, and are proposed as a standard assay for comparing neutralization investigations

    Human polyomaviruses, WU and KI in HIV exposed children with acute lower respiratory tract infections in hospitals in South Africa

    No full text
    BACKGROUND: The importance of two recently identified polyomaviruses, WUV and KIV, as respiratory pathogens in populations with a high HIV prevalence needs to be defined, since human polyomaviruses can cause significant morbidity and mortality in patients with immunosuppression. Geographic distribution and disease association of WUV and KIV genotypes are not yet clearly defined. OBJECTIVES: To investigate the prevalence of WUV and KIV in HIV-positive and HIV-negative patients with respiratory infections in hospitals in South Africa and determine their genotypes. STUDY DESIGN: Specimens from patients with acute respiratory infections from hospitals serving Pretoria were screened for WUV and KIV. Positive specimens were sequenced and subjected to phylogenetic analysis. RESULTS: WUV was identified in (7%) and KIV in (1%) of mainly pediatric patients. Co-infections were common in WUV- and KIV-infected patients (71% and 66.6%, respectively); 57% of patients with WUV and 33% of patients with KIV were HIV-positive while the HIV prevalence in the respiratory virus patient group screened in this study was 33% WUV and KIV patients presented with moderate to severe lower respiratory tract disease. Four distinct and 2 unique WUV strains were identified clustering into 2 of 4 globally identified genotypes. KIV strains were identical to strains from Sweden. CONCLUSION: WUV is frequently detected in HIV-infected patients with respiratory disease, but its role as respiratory pathogen remains uncertain

    A novel multiplex real-time RT-PCR assay with FRET hybridization probes for the detection and quantitation of 13 respiratory viruses

    No full text
    Quantitative multiplex real-time RT-PCR assays utilizing fluorescence resonance energy transfer (FRET) hybridization probes were developed for the detection of 13 respiratory viruses, including well recognized viral causes (respiratory syncytial virus, influenza viruses A and B, parainfluenza viruses types 1, 2, and 3, adenovirus) as well as viruses described recently as causes of acute respiratory tract infections (human coronaviruses NL63, HKU1, 229E, and OC43, human bocavirus, and human metapneumovirus). FRET probes have an improved toleration for single base mismatches than other probe chemistries, reducing the chances of missing highly variable RNA viruses. The assay could detect 2.5–25 DNA/RNA copies/μl (2.5 × 103–2.5 × 104 copies/ml). Validation on 91 known positive respiratory specimens indicated similar specificity as commercial direct immunofluorescence assays (IFA) or single-round PCRs used in initial identification. Screening of 270 IFA negative respiratory specimens identified new viruses in 40/270 (14.8%) cases and additional 79/270 (29.3%) well recognized viruses missed by routine diagnostic assays including 6.7% co-infections. All viruses could be detected in the clinical screening panel. The assays demonstrates an improved sensitivity and scope of detecting respiratory viruses relative to routine antigen detection assays while the quantitative utility may facilitate investigation of the role of co-infections and viral load in respiratory virus pathogenesis.This study has been funded by the Poliomyelitis Research Foundation

    Viral etiology of severe pneumonia among Kenyan infants and children

    No full text
    Context Pneumonia is the leading cause of childhood death in sub-Saharan Africa. Comparative estimates of the contribution of causative pathogens to the burden of disease are essential for targeted vaccine development. Objective To determine the viral etiology of severe pneumonia among infants and children at a rural Kenyan hospital using comprehensive and sensitive molecular diagnostic techniques. Design, Setting, and Participants Prospective observational and case-control study during 2007 in a rural Kenyan district hospital. Participants were children aged 1 day to 12 years, residing in a systematically enumerated catchment area, and who either were admitted to Kilifi District Hospital meeting World Health Organization clinical criteria for severe pneumonia or very severe pneumonia; (2) presented with mild upper respiratory tract infection but were not admitted; or (3) were well infants and children attending for immunization. Main Outcome Measures The presence of respiratory viruses and the odds ratio for admission with severe disease. Results Of 922 eligible admitted patients, 759 were sampled (82% [median age, 9 months]). One or more respiratory viruses were detected in 425 of the 759 sampled (56% [95% confidence interval {CI}, 52%-60%]). Respiratory syncytial virus (RSV) was detected in 260 participants (34% [95% CI, 31%-38%]) and other respiratory viruses were detected in 219 participants (29%; 95% CI, 26%-32%), the most common being Human coronavirus 229E (n=51 [6.7%]), influenza type A (n=44 [5.8%]), Parainfluenza type 3 (n=29 [3.8%]), Human adenovirus (n=29 [3.8%]), and Human metapneumovirus (n=23 [3.0%]). Compared with well control participants, detection of RSV was associated with severe disease (5% in control participants; adjusted odds ratio, 6.11 [95% CI, 1.65-22.6]) while collectively, other respiratory viruses were not associated with severe disease (23% in control participants; adjusted odds ratio, 1.27 [95% CI, 0.64-2.52]). Conclusion In a sample of Kenyan infants and children admitted with severe pneumonia to a rural hospital, RSV was the predominant viral pathogen. JAMA. 2010;303(20):2051-2057 www.jama.co

    Neutralisation titres against SARS-CoV-2 are sustained 6 months after onset of symptoms in individuals with mild COVID-19

    No full text
    Background: Given the importance of neutralising antibodies in protection against SARS-CoV-2 infection, it is critical to assess neutralisation persistence long-term following recovery. This study investigated neutralisation titres against SARS-CoV-2 up to 6 months post-symptom onset in individuals with mild COVID-19. Methods: Plasma neutralisation titres in convalescent COVID-19 individuals were determined at baseline and 6 months post-symptom onset using a cell culture infectious SARS-CoV-2 assay. Total SARS-CoV-2 spike-specific IgG and IgA binding was measured using a lectin capture ELISA and compared between timepoints and correlated to neutralising titres. Findings: All 48 convalescent COVID-19 individuals were found to have detectable SARS-CoV-2 50% inhibitory dilution neutralisation titres (ID50) at baseline and 6 months post-symptom onset with mean ID50 of 1/943 and 1/411, respectively. SARS-CoV-2 neutralisation titres peaked within 1-2 months post-symptom onset. However, 50% of individuals showed comparable ID50 at baseline and 6 months post-symptom onset. Both SARS-CoV-2 spike-specific IgG and IgA levels correlated well with neutralising titres. IgG binding was found to be sustained up to 6 months post-symptom onset, whereas IgA levels declined. Interpretation: This study demonstrates durability of SARS-CoV-2 spike-specific IgG and neutralisation responses following recovery from mild COVID-19. Thus, all subjects included in this study might potentially have protective levels of neutralising antibodies 6 months post-symptom onset. This study also demonstrates a relationship between spike-specific IgA and neutralisation decline, with implications for long-term protection against SARS-CoV-2 infection. Funding: Novo Nordisk Foundation, Independent Research Fund Denmark and Danish Agency for Science and Higher Education

    SARS-CoV-2 neutralising antibody testing in Europe:Towards harmonisation of neutralising antibody titres for better use of convalescent plasma and comparability of trial data

    No full text
    We compared the performance of SARS-CoV-2 neutralising antibody testing between 12 European laboratories involved in convalescent plasma trials. Raw titres differed almost 100-fold differences between laboratories when blind-testing 15 plasma samples. Calibration of titres in relation to the reference reagent and standard curve obtained by testing a dilution series reduced the inter-laboratory variability ca 10-fold. The harmonisation of neutralising antibody quantification is a vital step towards determining the protective and therapeutic levels of neutralising antibodies

    Molecular epidemiology of the SARS-CoV-2 variant Omicron BA.2 sub-lineage in Denmark, 29 November 2021 to 2 January 2022

    No full text
    Following emergence of the SARS-CoV-2 variant Omicron in November 2021, the dominant BA.1 sub-lineage was replaced by the BA.2 sub-lineage in Denmark. We analysed the first 2,623 BA.2 cases from 29 November 2021 to 2 January 2022. No epidemiological or clinical differences were found between individuals infected with BA.1 versus BA.2. Phylogenetic analyses showed a geographic east-to-west transmission of BA.2 from the Capital Region with clusters expanding after the Christmas holidays. Mutational analysis shows distinct differences between BA.1 and BA.2
    corecore