169 research outputs found

    Cellulose acetate phthalate, a common pharmaceutical excipient, inactivates HIV-1 and blocks the coreceptor binding site on the virus envelope glycoprotein gp120

    Get PDF
    BACKGROUND: Cellulose acetate phthalate (CAP), a pharmaceutical excipient used for enteric film coating of capsules and tablets, was shown to inhibit infection by the human immunodeficiency virus type 1 (HIV-1) and several herpesviruses. CAP formulations inactivated HIV-1, herpesvirus types 1 (HSV-1) and 2 (HSV-2) and the major nonviral sexually transmitted disease (STD) pathogens and were effective in animal models for vaginal infection by HSV-2 and simian immunodeficiency virus. METHODS: Enzyme-linked immunoassays and flow cytometry were used to demonstrate CAP binding to HIV-1 and to define the binding site on the virus envelope. RESULTS: 1) CAP binds to HIV-1 virus particles and to the envelope glycoprotein gp120; 2) this leads to blockade of the gp120 V3 loop and other gp120 sites resulting in diminished reactivity with HIV-1 coreceptors CXCR4 and CCR5; 3) CAP binding to HIV-1 virions impairs their infectivity; 4) these findings apply to both HIV-1 IIIB, an X4 virus, and HIV-1 BaL, an R5 virus. CONCLUSIONS: These results provide support for consideration of CAP as a topical microbicide of choice for prevention of STDs, including HIV-1 infection

    Effectiveness of an online curriculum for medical students on genetics, genetic testing and counseling

    Get PDF
    Background: It is increasingly important that physicians have a thorough understanding of the basic science of human genetics and the ethical, legal and social implications (ELSI) associated with genetic testing and counseling. Methods: The authors developed a series of web-based courses for medical students on these topics. The course modules are interactive, emphasize clinical case studies, and can easily be incorporated into existing medical school curricula. Results: Results of a ‘real world’ effectiveness trial indicate that the courses have a statistically significant effect on knowledge, attitude, intended behavior and self-efficacy related to genetic testing (p<0.001; N varies between 163 and 596 for each course). Conclusions: The results indicate that this curriculum is an effective tool for educating medical students on the ELSI associated with genetic testing and for promoting positive changes in students' confidence, counseling attitudes and behaviors

    PRimary Care Opioid Use Disorders treatment (PROUD) trial protocol: a pragmatic, cluster-randomized implementation trial in primary care for opioid use disorder treatment

    Get PDF
    BACKGROUND: Most people with opioid use disorder (OUD) never receive treatment. Medication treatment of OUD in primary care is recommended as an approach to increase access to care. The PRimary Care Opioid Use Disorders treatment (PROUD) trial tests whether implementation of a collaborative care model (Massachusetts Model) using a nurse care manager (NCM) to support medication treatment of OUD in primary care increases OUD treatment and improves outcomes. Specifically, it tests whether implementation of collaborative care, compared to usual primary care, increases the number of days of medication for OUD (implementation objective) and reduces acute health care utilization (effectiveness objective). The protocol for the PROUD trial is presented here. METHODS: PROUD is a hybrid type III cluster-randomized implementation trial in six health care systems. The intervention consists of three implementation strategies: salary for a full-time NCM, training and technical assistance for the NCM, and requiring that three primary care providers have DEA waivers to prescribe buprenorphine. Within each health system, two primary care clinics are randomized: one to the intervention and one to Usual Primary Care. The sample includes all patients age 16-90 who visited the randomized primary care clinics from 3 years before to 2 years after randomization (anticipated to be \u3e 170,000). Quantitative data are derived from existing health system administrative data, electronic medical records, and/or health insurance claims ( electronic health records, [EHRs]). Anonymous staff surveys, stakeholder debriefs, and observations from site visits, trainings and technical assistance provide qualitative data to assess barriers and facilitators to implementation. The outcome for the implementation objective (primary outcome) is a clinic-level measure of the number of patient days of medication treatment of OUD over the 2 years post-randomization. The patient-level outcome for the effectiveness objective (secondary outcome) is days of acute care utilization [e.g. urgent care, emergency department (ED) and/or hospitalizations] over 2 years post-randomization among patients with documented OUD prior to randomization. DISCUSSION: The PROUD trial provides information for clinical leaders and policy makers regarding potential benefits for patients and health systems of a collaborative care model for management of OUD in primary care, tested in real-world diverse primary care settings

    A 6-months assessment of the alcohol-related clinical burden at emergency rooms (ERs) in 11 acute care hospitals of an urban area in Germany

    Get PDF
    BACKGROUND: The purpose of the study was to identify and to profile alcohol-related attendances to emergency rooms (ERs) of 11 hospitals of various medical specialties covering a large urban population, to assess risk factors associated with short-stay cases, repeat attendances and higher degree of alcohol consumption and to estimate their impact on the alcohol-related burden at ERs. METHODS: A 6-months study was carried out to obtain clinical and administrative data on single and multiple attendances at ERs in 11 governmental acute hospitals in a large city in Germany. All alcohol-related attendances at ERs of study hospitals were eligible. A broad definition of alcohol-related attendances independently from alcohol diagnosis and various demographic, clinical and administrative measures were used. Odds ratios for the associations of these measures with duration of stay, repeat attendances and higher degrees of alcohol consumption were derived from multivariate binomial and multinomial logistic regression models. RESULTS: 1,748 patients with symptoms of alcohol consumption or withdrawal (inclusion rate 83.8%) yielded 2,372 attendances (3% of all medical admissions), and resulted in 12,629 inpatient-days. These patients accounted for 10.7 cases per 1,000 inhabitants. The average duration of inpatient stay was 10 days. 1,451 of all patients (83%) presented once, whereas the median of repeat attendances was three for the remaining 297 patients. Short-stay cases (<24 hours) were significantly linked with male gender, alcohol misuse, trauma (or suspicion of a trauma) and medical specialties. Increased levels of alcohol consumption at first attendance were significantly associated with repeat attendances in due course. In a multinomial logistic regression model higher degrees of alcohol consumption were significantly associated with male gender, trauma, short-stays, attendance outside regular working time, and with repeat attendances and self-discharge. CONCLUSION: Apart from demographic factors, the alcohol-related clinical burden is largely determined by short-stay cases, repeat attendances and cases with higher levels of alcohol consumption at first attendance varying across medical specialties. These findings could be relevant for the planning of anti-alcoholic interventions at ERs

    β-Catenin Signaling Increases during Melanoma Progression and Promotes Tumor Cell Survival and Chemoresistance

    Get PDF
    Beta-catenin plays an important role in embryogenesis and carcinogenesis by controlling either cadherin-mediated cell adhesion or transcriptional activation of target gene expression. In many types of cancers nuclear translocation of beta-catenin has been observed. Our data indicate that during melanoma progression an increased dependency on the transcriptional function of beta-catenin takes place. Blockade of beta-catenin in metastatic melanoma cell lines efficiently induces apoptosis, inhibits proliferation, migration and invasion in monolayer and 3-dimensional skin reconstructs and decreases chemoresistance. In addition, subcutaneous melanoma growth in SCID mice was almost completely inhibited by an inducible beta-catenin knockdown. In contrast, the survival of benign melanocytes and primary melanoma cell lines was less affected by beta-catenin depletion. However, enhanced expression of beta-catenin in primary melanoma cell lines increased invasive capacity in vitro and tumor growth in the SCID mouse model. These data suggest that beta-catenin is an essential survival factor for metastatic melanoma cells, whereas it is dispensable for the survival of benign melanocytes and primary, non-invasive melanoma cells. Furthermore, beta-catenin increases tumorigenicity of primary melanoma cell lines. The differential requirements for beta-catenin signaling in aggressive melanoma versus benign melanocytic cells make beta-catenin a possible new target in melanoma therapy

    Polyaniline/palladium nanohybrids for moisture and hydrogen detection.

    Get PDF
    Palladium nanoparticles display fascinating electronic, optical and catalytic properties, thus they can be used for various applications such as sensor fabrication. Conducting polymers such as polyaniline have also been widely used in sensor technology due to its cost effectiveness, versatility, and ease of synthesis. In this research, attention was given to unify the exceptional properties of these two materials and construct palladium nanoparticle coated polyaniline films to detect hydrogen and moisture. Electrochemical polymerization of aniline was carried out on gold sputtered epoxy resin boards. Polyaniline film was generated across a gap of 0.2 mm created by a scratch made on the gold coating prior to electrochemical polymerization. A palladium nanoparticle dispersion was prepared using sonochemical reduction method and coated on to polyaniline film using drop-drying technique. Polyaniline only films were also fabricated for comparative analysis. Sensitivity of films towards humidity and hydrogen was evaluated using impedance spectroscopy in the presence of the respective species. According to the results, polyaniline films exhibited an impedance drop in the presence of humidity and the response was significantly improved once palladium nanoparticles were incorporated. Interestingly, polyaniline only films did not respond to hydrogen. Nevertheless, palladium nanoparticle coated polyaniline films exhibited remarkable response towards hydrogen

    Diagnostic accuracy for the extent and activity of newly diagnosed and relapsed Crohn’s disease: a multicentre prospective comparison of magnetic resonance enterography and small bowel ultrasound –The METRIC Trial

    Get PDF
    Background Magnetic resonance enterography (MRE) and ultrasound (US) are used to image Crohn’s disease, but comparative accuracy for disease extent and activity is not known with certainty. We undertook a prospective multicentre cohort trial to address this Methods We recruited from 8 UK hospitals. Eligible patients were 16 years or older, newly diagnosed with Crohn’s disease, or had established disease with suspected relapse. Consecutive patients underwent MRE and US in addition to standard investigations. Discrepancy between MRE and US for small bowel (SB) disease presence triggered an additional investigation, if not already available. The primary outcome was difference in per patient sensitivity for SB disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). Accuracy for SB and colonic disease presence and activity were secondary outcomes. The trial is completed (ISRCTN03982913). Findings 284 patients completed the trial (133 new diagnosis, 151 relapse). MRE sensitivity (n=233) for SB disease extent (80% [95%CI 72 to 86]) and presence (97% [91 to 99]) were significantly greater than US (70% [62 to 78], 92% [84 to 96]); a 10% (1 to 18; p=0.027), and 5% (1 to 9), difference respectively. MRE specificity for SB disease extent (95% [85 to 98]) was significantly greater than US (81% [64 to 91]). Sensitivity for active SB disease was significantly greater for MRE than US (96% [92 to 99] vs. 90% [82 to 95]), difference 6% (2 to 11). Overall, there were no significant accuracy differences for colonic disease presence. Accuracy in newly diagnosed and relapse patients was similar, although US had significantly greater sensitivity for colonic disease than MRE in newly diagnosed patients (67% [49 to 81) vs. 47% [31 to 64]), difference 20% (1 to 39). There were no serious adverse events. Interpretation MRE has higher diagnostic accuracy for the extent and activity of SB Crohn’s disease than US when tested in a prospective multi centre cohort trial setting

    Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial

    Get PDF
    Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. National Institute of Health and Research Health Technology Assessment. [Abstract copyright: Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

    Use of SMS texts for facilitating access to online alcohol interventions: a feasibility study

    Get PDF
    A41 Use of SMS texts for facilitating access to online alcohol interventions: a feasibility study In: Addiction Science & Clinical Practice 2017, 12(Suppl 1): A4
    corecore