    Risk Factors for CIED Infection After Secondary Procedures

    Get PDF
    OBJECTIVES This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures. (J Am Coll Cardiol EP 2022;8:101-111) (c) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

    Infectious consequences of hematoma from cardiac implantable electronic device procedures and the role of the antibiotic envelope: A WRAP-IT trial analysis.

    Get PDF
    Hematoma is a complication of cardiac implantable electronic device (CIED) procedures and may lead to device infection. The TYRX antibacterial envelope reduced major CIED infection by 40% in the randomized WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention Trial) study, but its effectiveness in the presence of hematoma is not well understood.The purpose of this study was to evaluate the incidence and infectious consequences of hematoma and the association between envelope use, hematomas, and major CIED infection among WRAP-IT patients.All 6800 study patients were included in this analysis (control 3429; envelope 3371). Hematomas occurring within 30 days postprocedure (acute) were characterized and grouped by study treatment and evaluated for subsequent infection risk. Data were analyzed using Cox proportional hazard regression modeling.Acute hematoma incidence was 2.2% at 30 days, with no significant difference between treatment groups (envelope vs control hazard ratio [HR] 1.15; 95% confidence interval [CI] 0.84-1.58; P = .39). Through all follow-up, the risk of major infection was significantly higher among control patients with hematoma vs those without (13.1% vs 1.6%; HR 11.3; 95% CI 5.5-23.2; P.001). The risk of major infection was significantly lower in the envelope vs control patients with hematoma (2.5% vs 13.1%; HR 0.18; 95% CI 0.04-0.85; P = .03).The risk of hematoma was 2.2% among WRAP-IT patients. Among control patients, hematoma carried a11-fold risk of developing a major CIED infection. This risk was significantly mitigated with antibacterial envelope use, with an 82% reduction in major CIED infection among envelope patients who developed hematoma compared to control

    the world wide randomized antibiotic envelope infection prevention wrap it trial long term follow up

    Get PDF
    Abstract Background The WRAP-IT trial reported a 40% reduction in major CIED infection within 12 months of the procedure with the antibacterial-eluting envelope (TYRX). Objective This report describes the longer-term (>12 months) envelope effects on infection reduction and complications. Methods All trial patients that underwent CIED replacement, upgrade, revision, or initial CRT-D implant received standard-of-care infection prophylaxis and were randomized 1:1 to receive the envelope or not. CIED infection incidence, and procedure and system-related complications were characterized through all follow-up (36 months) using Cox proportional hazard regression modeling. Results In total, 6800 patients received their intended randomized treatment (3371 envelope; 3429 control; mean follow-up 21.0±8.3 months). Major CIED-related infection occurred in 32 envelope patients and 51 control patients (KM estimate, 1.3% vs. 1.9%; HR: 0.64, 95% CI: 0.41-0.99; P=0.046). Any CIED-related infection occurred in 57 envelope patients and 84 control patients (KM estimate, 2.1% vs. 2.8%; HR: 0.69, 95% CI: 0.49-0.97; P=0.030). System- or procedure-related complications occurred in 235 envelope patients and 252 control patients (KM estimate, 8.0% vs. 8.2%; HR, 0.95, 95% CI: 0.79-1.13; P Conclusions The effects of the TYRX envelope in reducing the risk of CIED infection are sustained beyond the first year post-procedure, without increased risk of complication

    The Long-Baseline Neutrino Experiment: Exploring Fundamental Symmetries of the Universe

    Get PDF
    The preponderance of matter over antimatter in the early Universe, the dynamics of the supernova bursts that produced the heavy elements necessary for life and whether protons eventually decay --- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our Universe, its current state and its eventual fate. The Long-Baseline Neutrino Experiment (LBNE) represents an extensively developed plan for a world-class experiment dedicated to addressing these questions. LBNE is conceived around three central components: (1) a new, high-intensity neutrino source generated from a megawatt-class proton accelerator at Fermi National Accelerator Laboratory, (2) a near neutrino detector just downstream of the source, and (3) a massive liquid argon time-projection chamber deployed as a far detector deep underground at the Sanford Underground Research Facility. This facility, located at the site of the former Homestake Mine in Lead, South Dakota, is approximately 1,300 km from the neutrino source at Fermilab -- a distance (baseline) that delivers optimal sensitivity to neutrino charge-parity symmetry violation and mass ordering effects. This ambitious yet cost-effective design incorporates scalability and flexibility and can accommodate a variety of upgrades and contributions. With its exceptional combination of experimental configuration, technical capabilities, and potential for transformative discoveries, LBNE promises to be a vital facility for the field of particle physics worldwide, providing physicists from around the globe with opportunities to collaborate in a twenty to thirty year program of exciting science. In this document we provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess.Comment: Major update of previous version. This is the reference document for LBNE science program and current status. Chapters 1, 3, and 9 provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess. 288 pages, 116 figure

    Low Genetic Variation in the Heath Hen Prior to Extinction and Implications for the Conservation of Prairie-Chicken Populations

    Full text link
    Low genetic variation is often considered to contribute to the extinction of species when they reach small population sizes. In this study we examined the mitochondrial control region from museum specimens of the Heath Hen ( Tympanuchus cupido cupido ), which went extinct in 1932. Today, the closest living relatives of the Heath Hen, the Greater ( T. c. pinnatus ), Attwater’s ( T. c. attwateri ) and Lesser ( T. pallidicinctus ) Prairie-chicken, are declining throughout most of their range in Midwestern North America, and loss of genetic variation is a likely contributor to their decline. Here we show that 30 years prior to their extinction, Heath Hens had low levels of mitochondrial genetic variation when compared with contemporary populations of prairie-chickens. Furthermore, some current populations of Greater Prairie-chickens are isolated and losing genetic variation due to drift. We estimate that these populations will reach the low levels of genetic variation found in Heath Hens within the next 40 years. Genetic variation and fitness can be restored with translocation of individuals from other populations; however, we also show that choosing an appropriate source population for translocation can be difficult without knowledge of historic population bottlenecks and their effect on genetic structure.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/42596/1/10592_2005_Article_7856.pd

    Impact of Cardiac Implantable Electronic Device Infection: A Clinical and Economic Analysis of the WRAP-IT Trial.

    No full text
    BACKGROUND: Current understanding of the impact of cardiac implantable electronic device (CIED) infection is based on retrospective analyses from medical records or administrative claims data. The WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) offers an opportunity to evaluate the clinical and economic impacts of CIED infection from the hospital, payer, and patient perspectives in the US healthcare system. METHODS: This was a prespecified, as-treated analysis evaluating outcomes related to major CIED infections: mortality, quality of life, disruption of CIED therapy, healthcare utilization, and costs. Payer costs were assigned using medicare fee for service national payments, while medicare advantage, hospital, and patient costs were derived from similar hospital admissions in administrative datasets. RESULTS: Major CIED infection was associated with increased all-cause mortality (12-month risk-adjusted hazard ratio, 3.41 [95% CI, 1.81-6.41]; CONCLUSIONS: This large, prospective analysis corroborates and extends understanding of the impact of CIED infections as seen in real-world datasets. CIED infections severely impact mortality, quality of life, healthcare utilization, and cost in the US healthcare system. Registration: URL: https://www.clinicaltrials.gov Unique Identifier: NCT02277990

    Antibacterial Envelope to Prevent Cardiac Implantable Device Infection

    Full text link
    BACKGROUND Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.)

    Antibacterial Envelope to Prevent Cardiac Implantable Device Infection

    No full text
    Background Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. Methods We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. Results A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P=0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P&lt;0.001 for noninferiority). The mean (+/- SD) duration of follow-up was 20.7 +/- 8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). Conclusions Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications

    Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics

    No full text
    The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based. This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized. This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large