1,191 research outputs found
Sensing electric fields using single diamond spins
The ability to sensitively detect charges under ambient conditions would be a
fascinating new tool benefitting a wide range of researchers across
disciplines. However, most current techniques are limited to low-temperature
methods like single-electron transistors (SET), single-electron electrostatic
force microscopy and scanning tunnelling microscopy. Here we open up a new
quantum metrology technique demonstrating precision electric field measurement
using a single nitrogen-vacancy defect centre(NV) spin in diamond. An AC
electric field sensitivity reaching ~ 140V/cm/\surd Hz has been achieved. This
corresponds to the electric field produced by a single elementary charge
located at a distance of ~ 150 nm from our spin sensor with averaging for one
second. By careful analysis of the electronic structure of the defect centre,
we show how an applied magnetic field influences the electric field sensing
properties. By this we demonstrate that diamond defect centre spins can be
switched between electric and magnetic field sensing modes and identify
suitable parameter ranges for both detector schemes. By combining magnetic and
electric field sensitivity, nanoscale detection and ambient operation our study
opens up new frontiers in imaging and sensing applications ranging from
material science to bioimaging
High spatial and temporal resolution wide-field imaging of neuron activity using quantum NV-diamond
A quantitative understanding of the dynamics of biological neural networks is fundamental to gaining insight into information processing in the brain. While techniques exist to measure spatial or temporal properties of these networks, it remains a significant challenge to resolve the neural dynamics with subcellular spatial resolution. In this work we consider a fundamentally new form of wide-field imaging for neuronal networks based on the nanoscale magnetic field sensing properties of optically active spins in a diamond substrate. We analyse the sensitivity of the system to the magnetic field generated by an axon transmembrane potential and confirm these predictions experimentally using electronically-generated neuron signals. By numerical simulation of the time dependent transmembrane potential of a morphologically reconstructed hippocampal CA1 pyramidal neuron, we show that the imaging system is capable of imaging planar neuron activity non-invasively at millisecond temporal resolution and micron spatial resolution over wide-fields
Cloud impacts on photochemistry: Building a climatology of photolysis rates from the Atmospheric Tomography mission
Abstract. Measurements from actinic flux spectroradiometers on board the
NASA DC-8 during the Atmospheric Tomography (ATom) mission provide an
extensive set of statistics on how clouds alter photolysis rates (J values)
throughout the remote Pacific and Atlantic Ocean basins. J values control
tropospheric ozone and methane abundances, and thus clouds have been included
for more than three decades in tropospheric chemistry modeling. ATom made
four profiling circumnavigations of the troposphere capturing each of the
seasons during 2016–2018. This work examines J values from the Pacific
Ocean flights of the first deployment, but publishes the complete Atom-1 data
set (29 July to 23 August 2016). We compare the observed J values (every 3 s along flight track) with those calculated by nine global
chemistry–climate/transport models (globally gridded, hourly, for a
mid-August day). To compare these disparate data sets, we build a
commensurate statistical picture of the impact of clouds on J values using
the ratio of J-cloudy (standard, sometimes cloudy conditions) to J-clear
(artificially cleared of clouds). The range of modeled cloud effects is
inconsistently large but they fall into two distinct classes: (1) models with
large cloud effects showing mostly enhanced J values aloft and or
diminished at the surface and (2) models with small effects having nearly
clear-sky J values much of the time. The ATom-1 measurements generally
favor large cloud effects but are not precise or robust enough to point out
the best cloud-modeling approach. The models here have resolutions of 50–200 km
and thus reduce the occurrence of clear sky when averaging over grid
cells. In situ measurements also average scattered sunlight over a mixed
cloud field, but only out to scales of tens of kilometers. A primary uncertainty
remains in the role of clouds in chemistry, in particular, how models average
over cloud fields, and how such averages can simulate measurements.
NERC ACSIS LTSM projec
Using the Prevalence of Individual Species of Intestinal Nematode Worms to Estimate the Combined Prevalence of Any Species
Mixed infections with roundworm, whipworm and hookworm are common, but survey reports often give only the separate prevalence of each type. However, the combined prevalence is important to estimate accurately the number of individuals who would benefit from control programmes and to make decisions about the frequency of treatment. Previous work suggests that mixed infections involving hookworm occur randomly, but that roundworm and whipworm infections are found together more frequently than would be expected by chance. We used 63 data sets from community surveys that reported both the proportions infected with individual types of worms and the combined proportion infected with any worm. We then calculated the proportion that would be infected with any type of worm if infections had occurred randomly and compared it with the observed combined proportion infected. We found a strong correlation between the observed and predicted combined proportions infected. A small downward correction of the predicted proportion infected by dividing by a factor of 1.06 brought it to a value that nearly equalled the observed proportion infected almost all the time. This simple model could be applied to published survey data to estimate accurately the number of individuals that would benefit from mass deworming
A 30-Min Nucleic Acid Amplification Point-of-Care Test for Genital Chlamydia trachomatis Infection in Women: A Prospective, Multi-center Study of Diagnostic Accuracy.
BACKGROUND: Rapid Point-Of-Care Tests for Chlamydia trachomatis (CT) may reduce onward transmission and reproductive sexual health (RSH) sequelae by reducing turnaround times between diagnosis and treatment. The io® single module system (Atlas Genetics Ltd.) runs clinical samples through a nucleic acid amplification test (NAAT)-based CT cartridge, delivering results in 30min. METHODS: Prospective diagnostic accuracy study of the io® CT-assay in four UK Genito-Urinary Medicine (GUM)/RSH clinics on additional-to-routine self-collected vulvovaginal swabs. Samples were tested "fresh" within 10days of collection, or "frozen" at -80°C for later testing. Participant characteristics were collected to assess risk factors associated with CT infection. RESULTS: CT prevalence was 7.2% (51/709) overall. Sensitivity, specificity, positive and negative predictive values of the io® CT assay were, respectively, 96.1% (95% Confidence Interval (CI): 86.5-99.5), 97.7% (95%CI: 96.3-98.7), 76.6% (95%CI: 64.3-86.2) and 99.7% (95%CI: 98.9-100). The only risk factor associated with CT infection was being a sexual contact of an individual with CT. CONCLUSIONS: The io® CT-assay is a 30-min, fully automated, high-performing NAAT currently CE-marked for CT diagnosis in women, making it a highly promising diagnostic to enable specific treatment, initiation of partner notification and appropriately intensive health promotion at the point of care
A 30-minute nucleic acid amplification point-of-care test for genital<i>Chlamydia trachomatis</i>infection in women: a prospective, multi-centre study of diagnostic accuracy
ABSTRACTBackgroundRapid Point-Of-Care Tests (POCTs) forChlamydia trachomatis(CT) may reduce onward transmission and reproductive sexual health (RSH) sequelae by reducing turnaround times between diagnosis and treatment. The io®single module system (Atlas Genetics Ltd) runs clinical samples through a microfluidic CT cartridge, delivering results in 30 minutes. We evaluated its performance on female genital samples in four UK Genito-Urinary Medicine (GUM)/RSH clinics.MethodsProspective diagnostic accuracy study, using BD ProbeTec CT/GC assay as the routine clinic nucleic acid amplification test (NAAT) as the initial comparator test, and the QIAgen Artus CT assay to resolve discrepancies. In these instances, the reference standard was defined as the resolved result when two out of three assay results concurred. Female participants aged ≥16 provided additional-to-routine self-collected vulvovaginal swabs. Samples were tested fresh with the io®CT assay within 7 days of collection, or were frozen at −80°C for later testing. Participant clinical, demographic and behavioural characteristics were collected to assess risk factors associated with CT infection.ResultsOf 785 participants recruited, final analyses were conducted on 709 (90.3%). CT prevalence was 7.2% (51/709) overall. Sensitivity, specificity, positive and negative predictive values of the io®CT assay were, respectively, 96.1% (95% Confidence Interval (CI): 86.5-99.5), 97.7% (95%CI: 96.3-98.7), 76.6% (95%CI: 64.3-86.2) and 99.7% (95%CI: 98.9-100). There was no significant difference in performance measures between fresh and frozen samples, or between symptomatic and asymptomatic participants (p>0.05). The only risk factor associated with CT infection was being a sexual contact of an individual with CT.ConclusionsThe io®CT-assay is the only 30-minute, fully automated, high-performing NAAT currently CE-marked for CT diagnosis in women, making it a highly promising diagnostic to enable specific treatment, initiation of partner notification and appropriately intensive health promotion at the point of care. Future research is required to evaluate acceptability by clinicians and patients in GUM/RSH clinics, impact on clinical pathways and patient management, and cost-effectiveness.</jats:sec
Nonvanishing effect of detuning errors in dynamical-decoupling-based quantum sensing experiments
Characteristic dips appear in the coherence traces of a probe qubit when dynamical decoupling (DD) is applied
in synchrony with the precession of target nuclear spins, forming the basis for nanoscale nuclear magnetic
resonance (NMR). The frequency of the microwave control pulses is chosen to match the qubit transition
but this can be detuned from resonance by experimental errors, hyperfine coupling intrinsic to the qubit, or
inhomogeneous broadening. The detuning acts as an additional static field which is generally assumed to be
completely removed in Hahn echo and DD experiments. Here we demonstrate that this is not the case in
the presence of finite pulse-durations, where a detuning can drastically alter the coherence response of the
probe qubit, with important implications for sensing applications. Using the electronic spin associated with a
nitrogen-vacancy center in diamond as a test qubit system, we analytically and experimentally study the qubit
coherence response under CPMG and XY8 dynamical decoupling control schemes in the presence of finite
pulse-durations and static detunings. Most striking is the splitting of the NMR resonance under CPMG, whereas
under XY8 the amplitude of the NMR signal is modulated. Our work shows that the detuning error must not be
neglected when extracting data from quantum sensor coherence traces
Modelling the effects of patch-plug configuration on the impact performance of patch-repaired composite laminates
The patch-plug configuration has been widely used to repair composite structures and restore the structural integrity of damaged composites. In the present research, single-sided CFRP patch-repaired panels, with different patch-plug configurations, are prepared. This is where a circular-shaped damaged area has been removed and a CFRP patch has been adhesively-bonded onto the panel. In some cases, a CFRP plug is inserted into the hole, caused by removal of the damaged area, before the patch is applied. Such patch-repaired panels, and the pristine CFRP panel, are subjected to a low-velocity impact at an energy of 7.5 J. These impacted pristine and repaired panels are then examined using ultrasonic C-scan and optical microscopy to inspect the impact-associated permanent indentation, interlaminar and intralaminar damage. A finite element analysis (FEA) model, which significantly extends a previously validated elastic-plastic (E-P) numerical damage model, has been developed to predict the impact behaviour of the pristine CFRP panel and the various designs of patch-repaired CFRP panels. The comparison between the experimental and numerical results for all the studied cases shows the maximum deviations for the loading response and the damage area are 12% and 15%, respectively. The good agreement between the experimentally-measured impact properties and those predicted using the numerical model demonstrates that the model is a useful design tool
Beautiful Mirrors at the LHC
We explore the "Beautiful Mirrors" model, which aims to explain the measured
value of , discrepant at the level. This scenario
introduces vector-like quarks which mix with the bottom, subtly affecting its
coupling to the . The spectrum of the new particles consists of two
bottom-like quarks and a charge -4/3 quark, all of which have electroweak
interactions with the third generation. We explore the phenomenology and
discovery reach for these new particles at the LHC, exploring single mirror
quark production modes whose rates are proportional to the same mixing
parameters which resolve the anomaly. We find that for mirror quark
masses is required to
reasonably establish the scenario and extract the relevant mixing parameters.Comment: version to be published in JHE
Geometry of the Intervertebral Volume and Vertebral Endplates of the Human Spine
Replacement of a degenerated vertebral disc with an artificial intervertebral disc (AID) is currently possible, but poses problems, mainly in the force distribution through the vertebral column. Data on the intervertebral disc space geometry will provide a better fit of the prosthesis to the vertebrae, but current literature on vertebral disc geometry is very scarce or not suitable. In this study, existing CT-scans of 77 patients were analyzed to measure the intervertebral disc and vertebral endplate geometry of the lumbar spine. Ten adjacent points on both sides of the vertebrae (S1-superior to T12-inferior) and sagittal and transverse diameters were measured to describe the shape of the caudal and cranial vertebral planes of the vertebrae. It was found that the largest endplate depth is located in the middle or posterior regions of the vertebra, that there is a linear relationship between all inferior endplate depths and the endplate location (p < 0.0001) within the spinal column, and that the superior endplate depth increases with age by about 0.01 mm per year (p < 0.02). The wedge angle increases from T12-L1 to L5-S1. The results allow for improvement of the fit of intervertebral disc-prostheses to the vertebrae and optimized force transmission through the vertebral column
- …