1,546 research outputs found
Smartphone-based chemiluminescent origami ”pad for the rapid assessment of glucose blood levels
Microfluidic paper analytical devices (”PADs) represent one of the most appealing trends in the development of simple and inexpensive analytical systems for diagnostic applications at the point of care (POC). Herein, we describe a smartphone-based origami ”PAD for the quantitative determination of glucose in blood samples based on the glucose oxidase-catalyzed oxidation of glucose leading to hydrogen peroxide, which is then detected by means of the luminol/hexacyanoferrate(III) chemiluminescent (CL) system. By exploiting the foldable ”PAD format, a two-step analytical procedure has been implemented. First, the diluted blood sample was added, and hydrogen peroxide was accumulated, then the biosensor was folded, and a transport buffer was added to bring hydrogen peroxide in contact with CL reagents, thus promoting the CL reaction. To enable POC applicability, the reagents required for the assay were preloaded in the ”PAD so that no chemicals handling was required, and a 3D-printed portable device was developed for measuring the CL emission using the smartphoneâs CMOS camera. The ”PAD was stable for 30-day storage at room temperature and the assay, displaying a limit of detection of 10 ”mol Lâ1, proved able to identify both hypoglycemic and hyperglycemic blood samples in less than 20 min
Null-stream veto for two co-located detectors: Implementation issues
Time-series data from multiple gravitational wave (GW) detectors can be
linearly combined to form a null-stream, in which all GW information will be
cancelled out. This null-stream can be used to distinguish between actual GW
triggers and spurious noise transients in a search for GW bursts using a
network of detectors. The biggest source of error in the null-stream analysis
comes from the fact that the detector data are not perfectly calibrated. In
this paper, we present an implementation of the null-stream veto in the
simplest network of two co-located detectors. The detectors are assumed to have
calibration uncertainties and correlated noise components. We estimate the
effect of calibration uncertainties in the null-stream veto analysis and
propose a new formulation to overcome this. This new formulation is
demonstrated by doing software injections in Gaussian noise.Comment: Minor changes; To appear in Class. Quantum Grav. (Proc. GWDAW10
d=2, N=2 Superconformal Symmetries and Models
We discuss the following aspects of two-dimensional N=2 supersymmetric
theories defined on compact super Riemann surfaces: parametrization of (2,0)
and (2,2) superconformal structures in terms of Beltrami coefficients and
formulation of superconformal models on such surfaces (invariant actions,
anomalies and compensating actions, Ward identities).Comment: 43 pages, late
Effect of 1\u3b1,25(OH)2 vitamin D3 in mutant P53 glioblastoma cells: Involvement of neutral sphingomyelinase1
Glioblastoma is one the most aggressive primary brain tumors in adults, and, despite the fact that radiation and chemotherapy after surgical approaches have been the treatments increasing the survival rates, the prognosis of patients remains poor. Today, the attention is focused on highlighting complementary treatments that can be helpful in improving the classic therapeutic approaches. It is known that 1\u3b1,25(OH)2 vitamin D3, a molecule involved in bone metabolism, has many serendipidy effects in cells. It targets normal and cancer cells via genomic pathway by vitamin D3 receptor or via non-genomic pathways. To interrogate possible functions of 1\u3b1,25(OH)2 vitamin D3 in multiforme glioblastoma, we used three cell lines, wild-type p53 GL15 and mutant p53 U251 and LN18 cells. We demonstrated that 1\u3b1,25(OH)2 vitamin D3 acts via vitamin D receptor in GL15 cells and via neutral sphingomyelinase1, with an enrichment of ceramide pool, in U251 and LN18 cells. Changes in sphingomyelin/ceramide content were considered to be possibly responsible for the differentiating and antiproliferative effect of 1\u3b1,25(OH)2 vitamin D in U251 and LN18 cells, as shown, respectively, in vitro by immunofluorescence and in vivo by experiments of xenotransplantation in eggs. This is the first time 1\u3b1,25(OH)2 vitamin D3 is interrogated for the response of multiforme glioblastoma cells in dependence on the p53 mutation, and the results define neutral sphingomyelinase1 as a signaling effector
Reflectance anisotropy spectroscopy assessment of the MOVPE nucleation of GaInP on Germanium (100)
This work summarizes the observations made on the variation and time evolution of the reflectanceanisotropy signal during the MOVPE growth of GaInPnucleation layers on Germanium substrates. This in situ monitoring tool is used to assess the impact of different nucleation routines and reactor conditions on the quality of the layers grown. This comparison is carried out by establishing a correlation between reflectanceanisotropy signature at 2.1 eV and the morphology of the epilayers evaluated by atomic force microscopy (AFM). This paper outlines the potential of reflectanceanisotropy to predict, explore, and therefore optimize, the best growth conditions that lead to a high quality IIIâV epilayer on a Ge substrat
The development and characteristics of a hand-held high power diode laser-based industrial tile grout removal and single-stage sealing system
As the field of laser materials processing becomes ever more diverse, the high power diode laser (HPDL) is now being regarded by many as the most applicable tool. The commercialisation of an industrial epoxy grout removal and single-stage ceramic tile grout sealing process is examined through the development of a hand-held HPDL device in this work. Further, an appraisal of the potential hazards associated with the use of the HPDL in an industrial environment and the solutions implemented to ensure that the system complies with the relevant safety standards are given. The paper describes the characteristics and feasibility of the industrial epoxy grout removal process. A minimum power density of approximately 3 kW/cm2 was found to exist, whilst the minimum interaction time, below which there was no removal of epoxy tile grout, was found to be approximately 0.5 s. The maximum theoretical removal rate that may be achievable was calculated as being 65.98 mm2/s for a circular 2 mm diameter beam with a power density of 3 kW/cm2 and a traverse speed of 42 mm/s. In addition, the characteristics of the single-stage ceramic tile grout sealing are outlined. The single-stage ceramic tile grout sealing process yielded crack and porosity free seals which were produced in normal atmospheric conditions. Tiles were successfully sealed with power densities as low as 550 W/cm2 and at rates of up to 420 mm/min. In terms of mechanical, physical and chemical characteristics, the single-stage ceramic tile grout was found to be far superior to the conventional epoxy tile grout and, in many instances, matched and occasionally surpassed that of the ceramic tiles themselves
Pandemic influenza A/H1N1 2009 antibodies in the metropolitan area of Buenos Aires in Argentina
SummaryObjectiveTo estimate the infection prevalence in Buenos Aires during the outbreak of pandemic influenza A/H1N1 2009 virus (A(H1N1)pdm09).MethodsA(H1N1)pdm09-specific antibodies were measured by hemagglutination inhibition assay in human serum samples collected 6 months after the outbreak and before the introduction of the A(H1N1)pdm09 vaccine in Argentina. Baseline levels of cross-reactive antibodies to A(H1N1)pdm09 were determined by testing 162 serum samples collected before 2009.ResultsThe overall seroprevalence of A(H1N1)pdm09 in 150 children and 427 adults was 28.9% (95% confidence interval (CI) 25â33%), with a 58.0% prevalence in children <19 years of age and an 18.7% prevalence in adults â„19 years of age (p<0.001). The prevalence was 43.5% in children <5 years old and 60.6% among children aged 5â18 years. The prevalence in adults declined with increasing age: 24.9% in 19â39-year-olds, 9.7% in 40â59-year-olds, and 8.1% in those â„60 years old. The prevalence of specific A(H1N1)pdm09 antibodies was higher compared with the baseline in children (p=0.014), adolescents (p<0.001), and adults <40 years old (p=0.017). Seroprevalence in health care workers was not different from the rest of the population (13.6% vs. 19.3%, respectively; p=0.421).ConclusionsThe prevalence of specific A(H1N1)pdm09 antibodies was high at 28.9%. The highest prevalence was observed in children, adolescents, and young adults
- âŠ