26 research outputs found
Iodine contrast agents do not influence Platelet-Rich Plasma function at an early time point in vitro
BACKGROUND: Iodine contrast agents (ICAs) are routinely used by radiologists to help guide intra-articular infiltrations. The aim of this study was to assess the in vitro effects of ICA on platelet function of human autologous Platelet-Rich Plasma (PRP). METHODS: One hundred thirty-seven consecutive patients with symptomatic femoral-patellar osteoarthritis were included. All were addressed to our institution for a fluoroscopy-guided intra-articular PRP infiltration of the pathological femoral-patellar joint. For each patient, 500 μl of PRP were sampled before intra-articular injection. First, PRP samples were mixed with 50 μl of 2 widely used ICA: Visipaque270® (Iodixanol, n = 58) and Iopamiron200® (Iopamidol, n = 69). PRP concentration ([PRP]) was measured at different delays of incubation (t = 0, 5, 10, 15, 20 and 30 min) enabling to calculate PRP ratio (defined as [PRP](t)/[PRP](0mn)) at each delay, for each mixture, in order to quantitatively assess the influence of ICA on PRP ratio. Second, the PRP samples of 10 additional patients were mixed with Visipaque270®, Visipaque270®, Iopamiron200® and phosphate buffer saline (PBS: control solution) in order to qualitatively assess the influence of ICA on platelet aggregation, using ADP, Collagen, Arachidonic acid and TRAP tests. The surface expression of human P-selectin, a marker of α-granule release, in the PRP + Visipaque270® and PRP + Iopamiron200® mixtures was finally compared. Repeated-measures ANOVA, classical 2-way ANOVA and Wilcoxon matched-pairs test were used to study the influence of ICA on PRP quality. RESULTS: There was no significant change in PRP ratio during the first 30mn of incubation (p = 0.991) whatever the ICA (p = 0.926). Whatever the aggregation test, there was no significant difference in the percentage of platelet aggregation between PRP + PBS, PRP + Visipaque270® and PRP + Iopamiron200® (p = 0.998), nor between PRP + PBS and PRP + Visipaque320® (p = 0.470). Finally, there was no significant difference in P-selectin expression between the PRP + Visipaque270® and PRP + Iopamiron200® mixtures (p = 0.500). CONCLUSION: At early delays of incubation, Visipaque® and Iopamiron®, which are two widely used ICA for intra-articular infiltrations, did not influence the in vitro platelet function nor the quality of PRP
Recommended from our members
Results of the Ontology Alignment Evaluation Initiative 2022
The Ontology Alignment Evaluation Initiative (OAEI) aims at comparing ontology matching systems on precisely defined test cases. These test cases can be based on ontologies of different levels of complexity and use different evaluation modalities. The OAEI 2022 campaign offered 14 tracks and was attended by 18 participants. This paper is an overall presentation of that campaign
Recommended from our members
Results of the Ontology Alignment Evaluation Initiative 2021
The Ontology Alignment Evaluation Initiative (OAEI) aims at comparing ontology matching systems on precisely defined test cases. These test cases can be based on ontologies of different levels of complexity and use different evaluation modalities (e.g., blind evaluation, open evaluation, or consensus). The OAEI 2021 campaign offered 13 tracks and was attended by 21 participants. This paper is an overall presentation of that campaign
Design of a Novel Compact and Superdirective Two and Three Elements Antenna Array
International audienc
Numerical Analysis of the size effect on a Printed 2D-irregular fractal-jet Antenna
International audienc
Planar Elliptic Broadband Antenna with Wide Range Reconfigurable Narrow Notched Bands for Multi-Standard Wireless Communication Devices
International audienc