85 research outputs found

    Spin interference in silicon three-terminal one-dimensional rings

    Full text link
    We present the first findings of the spin transistor effect in the Rashba gate-controlled ring embedded in the p-type self-assembled silicon quantum well that is prepared on the n-type Si (100) surface. The coherence and phase sensitivity of the spin-dependent transport of holes are studied by varying the value of the external magnetic field and the bias voltage that are applied perpendicularly to the plane of the double-slit ring. Firstly, the amplitude and phase sensitivity of the 0.7(2e^2/h) feature of the hole quantum conductance staircase revealed by the quantum point contact inserted in the one of the arms of the double-slit ring are found to result from the interplay of the spontaneous spin polarization and the Rashba spin-orbit interaction. Secondly, the quantum scatterers connected to two one-dimensional leads and the quantum point contact inserted are shown to define the amplitude and the phase of the Aharonov-Bohm and the Aharonov-Casher conductance oscillations.Comment: 8 pages, 5 figure

    High-efficiency deflection of high energy protons due to channeling along the (110) axis of a bent silicon crystal

    Get PDF
    A deflection efficiency of about 61% was observed for 400 GeV/c protons due to channeling, most strongly along the 〈110〉 axis of a bent silicon crystal. It is comparable with the deflection efficiency in planar channeling and considerably larger than in the case of the 〈111〉 axis. The measured probability of inelastic nuclear interactions of protons in channeling along the 〈110〉 axis is only about 10% of its amorphous level whereas in channeling along the (110) planes it is about 25%. High efficiency deflection and small beam losses make this axial orientation of a silicon crystal a useful tool for the beam steering of high energy charged particles

    Circularly polarized electroluminescence from silicon nanostructures heavily doped with boron

    Full text link
    The circularly polarized electroluminescence (CPEL) from silicon nanostructures which are the p-type ultra-narrow silicon quantum well (Si-QW) confined by {\delta}-barriers heavily doped with boron, 5 10^21 cm^-3, is under study as a function of temperature and excitation levels. The CPEL dependences on the forward current and temperature show the circularly polarized light emission which appears to be caused by the exciton recombination through the negative-U dipole boron centers at the Si-QW {\delta}-barriers interface

    Superconductivity in Silicon Nanostructures

    Full text link
    We present the findings of the superconductivity in the silicon nanostructures prepared by short time diffusion of boron after preliminary oxidation of the n-type Si (100) surface. These Si-based nanostructures represent the p-type high mobility silicon quantum well (Si-QW) confined by the delta - barriers heavily doped with boron. The ESR studies show that the delta - barriers appear to consist of the trigonal dipole centers, B(+)-B(-), which are caused by the negative-U reconstruction of the shallow boron acceptors, 2B(0)=>B(+)-B(-). The temperature and magnetic field dependencies of the resistance, thermo-emf, specific heat and magnetic susceptibility demonstrate that the high temperature superconductivity observed seems to result from the transfer of the small hole bipolarons through these negative-U dipole centers of boron at the Si-QW - delta - barrier interfaces. The value of the superconductor energy gap obtained is in a good agreement with the data derived from the oscillations of the conductance in normal state and of the zero-resistance supercurrent in superconductor state as a function of the bias voltage. These oscillations appear to be correlated by on- and off-resonance tuning the two-dimensional subbands of holes with the Fermi energy in the superconductor delta - barriers. Finally, the proximity effect in the S- Si-QW -S structure is revealed by the findings of the multiple Andreev reflection (MAR) processes and the quantization of the supercurrent

    Analysis on the Issue of East Financial Integration

    Get PDF
    在1997年金融危机发生后,东亚各国和地区意识到过分依赖外国的资金存在着巨大的风险。因此,为了避免对外国资金的过分依赖防止危机再次发生,东亚各国和地区通过完善金融体系,加强金融合作以推进金融一体化。 在此背景下,本文对东亚金融的一体化程度做出分析。本文对东亚各国和地区金融一体化的必要前提:东亚货币金融合作,东亚各国和地区资本市场放松管制情况、各国和地区的资本流动以及各国和地区股票及债券市场的发展进行了定性分析和描述,同时对各国投资与储蓄的相关性、各国消费者通过金融市场分散风险的程度、各国股票市场以及各国债券市场与两大国际市场间的联系,对东亚各国和地区金融市场一体化程度进行了实证分析。本文的研...East Asia has realized that it has great risk to depend on the foreign capital, after 1997 financial crisis. East Asia tried to improve the financial system and strengthen financial cooperation, so as to avoid the recurrence of financial crisis. This thesis tries to address the issue of the financial integration of East Asia. First of all, the basis of financial integration of East Asia was anal...学位:经济学博士院系专业:经济学院国际贸易系_世界经济学号:2005140292

    The impact of arterial input function determination variations on prostate dynamic contrast-enhanced magnetic resonance imaging pharmacokinetic modeling: a multicenter data analysis challenge, part II

    Get PDF
    This multicenter study evaluated the effect of variations in arterial input function (AIF) determination on pharmacokinetic (PK) analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data using the shutter-speed model (SSM). Data acquired from eleven prostate cancer patients were shared among nine centers. Each center used a site-specific method to measure the individual AIF from each data set and submitted the results to the managing center. These AIFs, their reference tissue-adjusted variants, and a literature population-averaged AIF, were used by the managing center to perform SSM PK analysis to estimate Ktrans (volume transfer rate constant), ve (extravascular, extracellular volume fraction), kep (efflux rate constant), and τi (mean intracellular water lifetime). All other variables, including the definition of the tumor region of interest and precontrast T1 values, were kept the same to evaluate parameter variations caused by variations in only the AIF. Considerable PK parameter variations were observed with within-subject coefficient of variation (wCV) values of 0.58, 0.27, 0.42, and 0.24 for Ktrans, ve, kep, and τi, respectively, using the unadjusted AIFs. Use of the reference tissue-adjusted AIFs reduced variations in Ktrans and ve (wCV = 0.50 and 0.10, respectively), but had smaller effects on kep and τi (wCV = 0.39 and 0.22, respectively). kep is less sensitive to AIF variation than Ktrans, suggesting it may be a more robust imaging biomarker of prostate microvasculature. With low sensitivity to AIF uncertainty, the SSM-unique τi parameter may have advantages over the conventional PK parameters in a longitudinal study

    QIN DAWG Validation of Gradient Nonlinearity Bias Correction Workflow for Quantitative Diffusion-Weighted Imaging in Multicenter Trials

    No full text
    Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multi-site clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, −35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI
    corecore