423 research outputs found

    Structures of smooth muscle myosin and heavy meromyosin in the folded, shutdown state

    Get PDF
    Remodelling of the contractile apparatus within smooth muscle cells is an essential process that allows effective contractile activity over a wide range of cell lengths. The thick filaments may be redistributed via depolymerisation into inactive myosin monomers that have been detected in vitro, in which the long tail has a folded conformation. The structure of this folded molecule has been controversial. Using negative stain electron microscopy of individual folded molecules from turkey gizzard we show they are more compact than previously described, with heads and the three segments of the folded tail closely packed. Smooth muscle heavy meromyosin (HMM), which lacks two-thirds of the tail, closely resembles the equivalent parts of whole myosin. Image processing reveals a characteristic head region morphology for both HMM and myosin whose features are identifiable by comparison with less compact molecules. The two heads associate asymmetrically: the tip of one motor domain touches the base of the other, resembling the blocked and free heads of this HMM when it forms 2-D crystals on lipid. The tail of HMM lies between the heads, contacting the blocked motor domain, unlike in the 2-D crystal. The tail of the intact myosin is bent sharply and consistently at two positions close to residues 1175 and 1535. The first bend position correlates with a skip in the coiled coil sequence, the second does not. The first segment runs between the heads from the head-tail junction. Unexpectedly, the other segments associate only with the blocked head rather than both heads, such that the second bend lies at a specific position near the C-lobe of the blocked head regulatory light chain. Quantitative analysis of tail flexibility shows that the single coiled coil of HMM has an apparent Young’s modulus of about 0.5 GPa. The folded tail of the intact molecule is less flexible indicating interactions between the segments. The folded tail does not modify the compact head arrangement but stabilises it, indicating a structural mechanism for the very low ATPase activity of the folded molecule

    Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease

    Get PDF
    Aims Cardiac hybrid imaging by fusing single-photon emission computed tomography (SPECT) myocardial perfusion imaging with coronary computed tomography angiography (CCTA) provides important complementary diagnostic information for coronary artery disease (CAD) assessment. We aimed at assessing the impact of cardiac hybrid imaging on the choice of treatment strategy selection for CAD. Methods and results Three hundred and eighteen consecutive patients underwent a 1 day stress/rest (99m)Tc-tetrofosmin SPECT and a CCTA on a separate scanner for evaluation of CAD. Patients were divided into one of the following three groups according to findings in the hybrid images obtained by fusing SPECT and CCTA: (i) matched finding of stenosis by CCTA and corresponding reversible SPECT defect; (ii) unmatched CCTA and SPECT finding; (iii) normal finding by both CCTA and SPECT. Follow-up was confined to the first 60 days after hybrid imaging as this allows best to assess treatment strategy decisions including the revascularization procedure triggered by its findings. Hybrid images revealed matched, unmatched, and normal findings in 51, 74, and 193 patients. The revascularization rate within 60 days was 41, 11, and 0% for matched, unmatched, and normal findings, respectively (P< 0.001 for all inter-group comparisons). Conclusion Cardiac hybrid imaging with SPECT and CCTA provides an added clinical value for decision making with regard to treatment strategy for CAD

    Wearable devices can predict the outcome of standardized 6-minute walk tests in heart disease

    Get PDF
    Wrist-worn devices with heart rate monitoring have become increasingly popular. Although current guidelines advise to consider clinical symptoms and exercise tolerance during decision-making in heart disease, it remains unknown to which extent wearables can help to determine such functional capacity measures. In clinical settings, the 6-minute walk test has become a standardized diagnostic and prognostic marker. We aimed to explore, whether 6-minute walk distances can be predicted by wrist-worn devices in patients with different stages of mitral and aortic valve disease. A total of n = 107 sensor datasets with 1,019,748 min of recordings were analysed. Based on heart rate recordings and literature information, activity levels were determined and compared to results from a 6-minute walk test. The percentage of time spent in moderate activity was a predictor for the achievement of gender, age and body mass index-specific 6-minute walk distances (p < 0.001; R2 = 0.48). The uncertainty of these predictions is demonstrated

    Impact of aging on immunity in the context of COVID-19, HIV, and tuberculosis

    Get PDF
    Knowledge of aging biology needs to be expanded due to the continuously growing number of elderly people worldwide. Aging induces changes that affect all systems of the body. The risk of cardiovascular disease and cancer increases with age. In particular, the age-induced adaptation of the immune system causes a greater susceptibility to infections and contributes to the inability to control pathogen growth and immune-mediated tissue damage. Since the impact of aging on immune function, is still to be fully elucidated, this review addresses some of the recent understanding of age-related changes affecting key components of immunity. The emphasis is on immunosenescence and inflammaging that are impacted by common infectious diseases that are characterized by a high mortality, and includes COVID-19, HIV and tuberculosis

    Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME): 5-year follow-up of a randomised controlled trial

    Get PDF
    In the Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) study, fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) improved outcome compared with angiography-guided PCI for up to 2 years of follow-up. The aim in this study was to investigate whether the favourable clinical outcome with the FFR-guided PCI in the FAME study persisted over a 5-year follow-up

    Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates

    Get PDF
    BACKGROUND: In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress-shielding of the layer of the bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. METHOD: In order to address this problem, we propose to use stiffness-graded plates. Accordingly, we have computed (by finite-element analysis) the stress distribution in the fractured bone fixed by composite plates, whose stiffness is graded both longitudinally and transversely. RESULTS: It can be seen that the stiffness-graded composite-plates cause less stress-shielding (as an example: at 50% of the healing stage, stress at the fracture interface is compressive in nature i.e. 0.002 GPa for stainless steel plate whereas stiffness graded plates provides tensile stress of 0.002 GPa. This means that stiffness graded plate is allowing the 50% healed bone to participate in loadings). Stiffness-graded plates are more flexible, and hence permit more bending of the fractured bone. This results in higher compressive stresses induced at the fractured faces accelerate bone-healing. On the other hand, away from the fracture interface the reduced stiffness and elastic modulus of the plate causes the neutral axis of the composite structure to be lowered into the bone resulting in the higher tensile stress in the bone-layer underneath the plate, wherein is conducive to the bone preserving its tensile strength. CONCLUSION: Stiffness graded plates (with in-built variable stiffness) are deemed to offer less stress-shielding to the bone, providing higher compressive stress at the fractured interface (to induce accelerated healing) as well as higher tensile stress in the intact portion of the bone (to prevent bone remodeling and osteoporosis)

    Utilizing Risk Scores in Determining the Optimal Revascularization Strategy for Complex Coronary Artery Disease

    Get PDF
    Percutaneous coronary intervention (PCI) of multivessel and/or left main stem disease have been shown to be potentially legitimate revascularization alternatives in appropriately selected patients. Risk stratification is an important component in guiding patients to identify the most appropriate revascularization modality (PCI or coronary artery bypass grafting [CABG]) in conjunction with the Heart Team. The aim of this paper is to give the clinician a concise overview of the important established and evolving contemporary risk models in aiding this decision-making process. Risk models, based on clinical and anatomical variables alone, the novel concept of functional anatomical risk scores, and risk models combining aspects from both clinical and anatomical scores, are all discussed. The emerging concepts of the patient-empowered risk/benefit tradeoff between PCI and CABG to help personalize the choice of revascularization modality are also explored

    Abbreviated Antiplatelet Therapy After Coronary Stenting in Patients With Myocardial Infarction at High Bleeding Risk.

    Get PDF
    BACKGROUND The optimal duration of antiplatelet therapy (APT) after coronary stenting in patients at high bleeding risk (HBR) presenting with an acute coronary syndrome remains unclear. OBJECTIVES The objective of this study was to investigate the safety and efficacy of an abbreviated APT regimen after coronary stenting in an HBR population presenting with acute or recent myocardial infarction. METHODS In the MASTER DAPT trial, 4,579 patients at HBR were randomized after 1 month of dual APT (DAPT) to abbreviated (DAPT stopped and 11 months single APT or 5 months in patients with oral anticoagulants) or nonabbreviated APT (DAPT for minimum 3 months) strategies. Randomization was stratified by acute or recent myocardial infarction at index procedure. Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes events (NACE); major adverse cardiac and cerebral events (MACCE); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS NACE and MACCE did not differ with abbreviated vs nonabbreviated APT regimens in patients with an acute or recent myocardial infarction (n = 1,780; HR: 0.83; 95% CI: 0.61-1.12 and HR: 0.86; 95% CI: 0.62-1.19, respectively) or without an acute or recent myocardial infarction (n = 2,799; HR: 1.03; 95% CI: 0.77-1.38 and HR: 1.13; 95% CI: 0.80-1.59; Pinteraction = 0.31 and 0.25, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding was significantly reduced in patients with or without an acute or recent myocardial infarction (HR: 0.65; 95% CI: 0.46-0.91 and HR: 0.71; 95% CI: 0.54-0.92; Pinteraction = 0.72) with abbreviated APT. CONCLUSIONS A 1-month DAPT strategy in patients with HBR presenting with an acute or recent myocardial infarction results in similar NACE and MACCE rates and reduces bleedings compared with a nonabbreviated DAPT strategy. (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen [MASTER DAPT]; NCT03023020)

    Dedicated plug based closure for large bore access -The MARVEL prospective registry

    Get PDF
    Objectives To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. Background The MANTA is a novel plug-based device for large bore arteriotomy closure. Methods We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. Results Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 +/- 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. Conclusion In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.Peer reviewe
    corecore