1,077 research outputs found

    Effects of dissolved organic carbon on methylmercury bioavailability in stream ecosystems

    Get PDF

    Geometric properties of a prestressed segmented spherical shell

    Get PDF
    Design and construction of plastic model of prestressed segmented spherical shel

    Development of a stroke assessment team: focus on physiotherapy

    Get PDF
    A multidisciplinary team was appointed for acute stroke services in preparation for opening a stroke assessment unit at Walsgrave Hospitals NHS Trust. Since introduction, the frequency of physiotherapy treatment for stroke patients has improved, as an indirect consequence of increasing awareness of therapy needs and greater staff confidence in treating stroke patients. </jats:p

    First impressions: effects of representation on video game covers.

    Get PDF
    This study presents findings about perceptions and impacts of representation on video game covers. Our analysis contributes to a growing discourse on representation in games and media, to urge designers and researchers alike to consider how perceptions and feelings related to representation begin, and influence interaction, before gameplay starts. We analyzed 298 responses to a survey that asked how participants felt about representation on samples of digital covers from Steam’s best-selling games from 2010-2015, and how those feelings affect their game consumption or purchases. Although our findings describe a consensus on a lack of adequate representation of characters of color, they identify significantly different perspectives, feelings, experiences, and practices related to games, covers, and representation between participants of color and white participants. Our analysis highlights how publishers must not only consider how they include diverse identities in games but communicate that inclusion beyond them

    Effects of dissolved organic carbon on methylmercury bioavailability in stream ecosystems

    Get PDF

    Silicon oxide nanowire growth mechanisms revealed by real-time electron microscopy

    Full text link
    © 2016 The Royal Society of Chemistry. Growth of one-dimensional materials is possible through numerous mechanisms that affect the nanowire structure and morphology. Here, we explain why a wide range of morphologies is observed when silicon oxide nanowires are grown on silicon substrates using liquid gallium catalyst droplets. We show that a gallium oxide overlayer is needed for nanowire nucleation at typical growth temperatures, and that it can decompose during growth and, hence, dramatically alter the nanowire morphology. Gallium oxide decomposition is attributed to etching caused by hydrogen that can be supplied by thermal dissociation of H2O (a common impurity). We show that H2O dissociation is catalyzed by silicon substrates at temperatures as low as 320 °C, identify the material supply pathways and processes that rate-limit nanowire growth under dry and wet atmospheres, and present a detailed growth model that explains contradictory results reported in prior studies. We also show that under wet atmospheres the Ga droplets can be mobile and promote nanowire growth as they traverse the silicon substrate

    Development of a multimedia tutorial to educate how to assess the critical view of safety in laparoscopic cholecystectomy using expert review and crowd-sourcing

    Get PDF
    We sought to determine the feasibility of developing a multimedia educational tutorial to teach learners to assess the critical view of safety using input from expert surgeons, non-surgeons and crowd-sourcing. We intended to develop a tutorial that would teach learners how to identify the basic anatomy and physiology of the gallbladder, identify the components of the critical view of safety criteria, and understand its significance for performing a safe gallbladder removal. Using rounds of assessment with experts, laypersons and crowd-workers we developed an educational video with improving comprehension after each round of revision. We demonstrate that the development of a multimedia educational tool to educate learners of various backgrounds is feasible using an iterative review process that incorporates the input of experts and crowd sourcing. When planning the development of an educational tutorial, a step-wise approach as described herein should be considered

    Measuring soil frost depth in forest ecosystems with ground penetrating radar

    Get PDF
    Soil frost depth in forest ecosystems can be variable and depends largely on early winter air temperaturesand the amount and timing of snowfall. A thorough evaluation of ecological responses to seasonallyfrozen ground is hampered by our inability to adequately characterize the frequency, depth, durationand intensity of soil frost events. We evaluated the use of ground penetrating radar to nondestructivelydelineate soil frost under field conditions in three forest ecosystems. Soil frost depth was monitoredperiodically using a 900 MHz antenna in South Burlington, Vermont (SB), Sleepers River Watershed,North Danville, Vermont (SR) and Hubbard Brook Experimental Forest, New Hampshire (HBEF) duringwinter 2011–2012 on plots with snow and cleared of snow. GPR-based estimates were compared to datafrom thermistors and frost tubes, which estimate soil frost depth with a color indicating solution. In theabsence of snow, frost was initially detected at a depth of 8–10 cm. Dry snow up to 35 cm deep, enhancednear-surface frost detection, raising the minimum frost detection depth to 4–5 cm. The most favorablesurface conditions for GPR detection were bare soil or shallow dry snow where frost had penetrated to theminimum detectable depth. Unfavorable conditions included: standing water on frozen soil, wet snow,thawed surface soils and deep snow pack. Both SB and SR were suitable for frost detection most of thewinter, while HBEF was not. Tree roots were detected as point reflections and were readily discriminatedfrom continuous frost reflections. The bias of GPR frost depth measurements relative to thermistors wassite dependent averaging 0.1 cm at SB and 1.1 cm at SR, and was not significantly different than zero. Whenseparated by snow manipulation treatment at SR, overestimation of soil frost depth (5.5 cm) occurredon plots cleared of snow and underestimation (−1.5 cm) occurred on plots with snow. Despite somelimitations posed by site and surface suitability, GPR could be useful for adding a spatial component topre-installed soil frost monitoring networks

    Rat mammary carcinogenesis following neutron- or X-radiation

    Get PDF
    Female 61 to 63 - day - old Sprague-Dawley rats were exposed once to a single dose of either 0.43 - MeV neutrons or 250 - kVX - rays . For neutrons 23 rats were exposed in plastic tubes rotated around and 31 c m from a water-cooled tritium impregnated target bombarded with 2.45 - MeV protons from a V a n de Graaff generator. The mean kerma was measured at the rat location by integrating the response of a rat - sized homogeneous tissue equivalent ionization chamber of minimum mass. The ratio between absorbed dose and kerma is under investigation and is anticipated to be approximately 0.7. A compensated GM gamma-ray dosimeter indicated that the gamma - ray doses were 3.5% of the total dose. All rats were examined weekly for the presence of breast tumours and these were removed, fixed, stained and verified histologically as mammary neoplasms. At 10 months after exposure 98<7ο of the rats were a live . The neutron kerma, the per cent of rats with mammary neoplasia, and the number of rats were, respectively: 0.125 rads, 8.2°}o, 182; 0.5 rads, 9.0^0, 89; 2 rads, 20. 6,68; and 8 rads, 31.1%, 45. The X - ray results were: 30 R, 1.4% 95; 60 R, 27. l°Io, 48; and 90 R, 35.4%, 48. A 3. O^o incidence was found in 167 control rats. At 10 months after exposure the mammary neoplastic response after 8 rads of neutrons corresponds approximately to that after 60 - 90 R of X - rays . Similarly, the response after 2 rads of neutrons was intermediate between 30 and 60 R of X - rays and the response after 0 . 125 and 0.5 rads of neutrons was similar to that after 30 R of X - rays . This demonstrates that the RBE for 0.43 - MeV neutrons is much lower at high doses than at low doses. Determination of the confidence limits for the dose-RBE dependence and dose-incidence relationship will be determined as additional data are collected
    • …
    corecore